Influence of tissue- and cell-scale extracellular matrix distribution on the mechanical properties of tissue-engineered cartilage

被引:0
|
作者
Mehdi Khoshgoftar
Wouter Wilson
Keita Ito
Corrinus C. van Donkelaar
机构
[1] Eindhoven University of Technology,Orthopaedic Biomechanics, Department of Biomedical Engineering
关键词
Inner Core; Surrounding Matrix; Matrix Distribution; Cell Scale; Fixed Charge Density;
D O I
暂无
中图分类号
学科分类号
摘要
The insufficient load-bearing capacity of today’s tissue- engineered (TE) cartilage limits its clinical application. Generally, cartilage TE studies aim to increase the extracellular matrix (ECM) content, as this is thought to determine the load-bearing properties of the cartilage. However, there are apparent inconsistencies in the literature regarding the correlation between ECM content and mechanical properties of TE constructs. In addition to the amount of ECM, the spatial inhomogeneities in ECM distribution at the tissue scale as well as at the cell scale may affect the mechanical properties of TE cartilage. The relative importance of such structural inhomogeneities on mechanical behavior of TE cartilage is unknown. The aim of the present study was, therefore, to theoretically elucidate the influence of these inhomogeneities on the mechanical behavior of chondrocyte-agarose TE constructs. A validated non-linear fiber-reinforced poro-elastic swelling cartilage model that can accommodate for effects of collagen reinforcement and swelling by proteoglycans was used. At the tissue scale, ECM was gradually varied from predominantly localized in the periphery of the TE construct toward an ECM-rich inner core. The effect of these inhomogeneities in relation to the total amount of ECM was also evaluated. At the cell scale, ECM was gradually varied from localized in the pericellular area, toward equally distributed throughout the interterritorial area. Results from the tissue-scale model indicated that localization of ECM in either the construct periphery or in the inner core may reduce construct stiffness compared with that of constructs with homogeneous ECM. Such effects are more significant at high ECM amounts. At the cell scale, localization of ECM around the cells significantly reduced the overall stiffness, even at low ECM amounts. The compressive stiffness gradually increased when ECM distribution became more homogeneous and the osmotic swelling pressure in the interterritorial area increased. We conclude that for the same amount of ECM content in TE cartilage constructs, superior mechanical properties can be achieved with more homogeneous ECM distribution at both tissue and cell scale. Inhomogeneities at the cell scale are more important than those at the tissue scale.
引用
收藏
页码:901 / 913
页数:12
相关论文
共 50 条
  • [1] Influence of tissue- and cell-scale extracellular matrix distribution on the mechanical properties of tissue-engineered cartilage
    Khoshgoftar, Mehdi
    Wilson, Wouter
    Ito, Keita
    van Donkelaar, Corrinus C.
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2013, 12 (05) : 901 - 913
  • [2] Influence of the Temporal Deposition of Extracellular Matrix on the Mechanical Properties of Tissue-Engineered Cartilage
    Khoshgoftar, Mehdi
    Wilson, Wouter
    Ito, Keita
    van Donkelaar, Corrinus C.
    [J]. TISSUE ENGINEERING PART A, 2014, 20 (9-10) : 1476 - 1485
  • [3] Influence of the extracellular matrix on the frictional properties of tissue-engineered cartilage
    Plainfosse, M.
    Hatton, P. V.
    Crawford, A.
    Jin, Z. M.
    Fisher, J.
    [J]. BIOCHEMICAL SOCIETY TRANSACTIONS, 2007, 35 : 677 - 679
  • [4] Influence of the extracellular matrix on the mechanical properties of tissue engineered cartilage
    Plainfosse, M.
    Hatton, P. V.
    Crawford, A.
    Katta, J.
    Jin, Z.
    Fisher, J.
    [J]. INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, 2007, 88 (06) : A87 - A87
  • [5] An extracellular matrix extract for tissue-engineered cartilage
    Lum, LY
    Cher, NLC
    Williams, CG
    Elisseeff, JH
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (05): : 71 - 76
  • [6] TISSUE- AND CELL-LEVEL INHOMOGENEITIES SIGNIFICANTLY ALTER THE MECHANICAL BEHAVIOR OF TISSUE-ENGINEERED CARTILAGE
    Khoshgoftar, M.
    Wilson, W.
    Ito, K.
    van Donkelaar, C. C.
    [J]. PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 1149 - 1150
  • [7] Mechanical Properties of Natural Cartilage and Tissue-Engineered Constructs
    Little, Christopher James
    Bawolin, Nahshon Kenneth
    Chen, Xiongbiao
    [J]. TISSUE ENGINEERING PART B-REVIEWS, 2011, 17 (04) : 213 - 227
  • [8] Biochemical Properties of Tissue-Engineered Cartilage
    Pappa, Andrew K.
    Caballero, Montserrat
    Dennis, Robert G.
    Skancke, Matthew D.
    Narayan, Roger J.
    Dahl, John P.
    van Aalst, John A.
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (01) : 111 - 115
  • [9] Compressive properties of tissue-engineered cartilage
    Horkay, F
    Horkayne-Szakaly, I
    Basser, PJ
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U579 - U580
  • [10] Quantitative Evaluation of Mechanical Properties in Tissue-Engineered Auricular Cartilage
    Nimeskern, Luc
    van Osch, Gerjo J. V. M.
    Mueller, Ralph
    Stok, Kathryn S.
    [J]. TISSUE ENGINEERING PART B-REVIEWS, 2014, 20 (01) : 17 - 27