Parallel imaging plays an important role to reduce data acquisition time in magnetic resonance imaging (MRI). Under-sampled non-Cartesian trajectories accelerate the MRI scan time, but the resulting images may have aliasing artifacts. To remove these artifacts, a variety of methods have been developed within the scope of parallel imaging in the recent past. In this paper, the use of Eigen-vector-based iterative Self-consistent Parallel Imaging Reconstruction Technique (ESPIRiT) along with self-calibrated GRAPPA operator gridding (self-calibrated GROG) on radial k-space data for accelerated MR image reconstruction is presented. The proposed method reconstructs the solution image from non-Cartesian k-space data in two steps: First, the acquired radial data is gridded using self-calibrated GROG and then ESPIRIT is applied on this gridded data to get the un-aliased image. The proposed method is tested on human head data and the short-axis cardiac radial data. The quality of the reconstructed images is evaluated using artifact power (AP), root-mean-square error (RMSE) and peak signal-to-noise ratio (PSNR) at different acceleration factors (AF). The results of the proposed method (GROG followed by ESPIRiT) are compared with GROG followed by pseudo-Cartesian GRAPPA reconstruction approach (conventionally used). The results show that the proposed method provides considerable improvement in the reconstructed images as compared to conventionally used pseudo-Cartesian GRAPPA with GROG, e.g., 87, 67 and 82% improvement in terms of AP for 1.5T, 3T human head and short-axis cardiac radial data, 63, 45 and 57% improvement in terms of RMSE for 1.5T, 3T human head and short-axis cardiac radial data, 11, 7 and 9% improvement in terms of PSNR for 1.5T, 3T human head and short-axis cardiac radial data, respectively, at AF = 4.
引用
收藏
页码:107 / 124
页数:17
相关论文
共 50 条
  • [1] Accelerating MRI Using GROG Gridding Followed by ESPIRiT for Non-Cartesian Trajectories
    Aslam, Ibtisam
    Najeeb, Faisal
    Omer, Hammad
    [J]. APPLIED MAGNETIC RESONANCE, 2018, 49 (01) : 107 - 124
  • [2] Non-Cartesian data reconstruction using GRAPPA operator gridding (GROG)
    Seiberlich, Nicole
    Breuer, Felix A.
    Blaimer, Martin
    Barkauskas, Kestutis
    Jakob, Peter M.
    Griswold, Mark A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1257 - 1265
  • [3] On NUFFT-based gridding for non-Cartesian MRI
    Fessler, Jeffrey A.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2007, 188 (02) : 191 - 195
  • [4] Accelerating Non-Cartesian MRI Reconstruction Convergence Using k-Space Preconditioning
    Ong, Frank
    Uecker, Martin
    Lustig, Michael
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (05) : 1646 - 1654
  • [5] Reconstruction of undersampled non-cartesian data sets using pseudo-cartesian GRAPPA in conjunction with GROG
    Seiberlich, Nicole
    Breuer, Felix
    Heidemann, Robin
    Blaimer, Martin
    Griswold, Mark
    Jakob, Peter
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) : 1127 - 1137
  • [6] Four-shot non-cartesian trajectories for k-space sampling in MRI
    Shubham Sharma
    K. V. S. Hari
    [J]. CSI Transactions on ICT, 2018, 6 (1) : 11 - 16
  • [7] GPU-Accelerated Self-Calibrating GRAPPA Operator Gridding for Rapid Reconstruction of Non-Cartesian MRI Data
    Inam, Omair
    Qureshi, Mahmood
    Malik, Shahzad A.
    Omer, Hammad
    [J]. APPLIED MAGNETIC RESONANCE, 2017, 48 (10) : 1055 - 1074
  • [8] GPU-Accelerated Self-Calibrating GRAPPA Operator Gridding for Rapid Reconstruction of Non-Cartesian MRI Data
    Omair Inam
    Mahmood Qureshi
    Shahzad A. Malik
    Hammad Omer
    [J]. Applied Magnetic Resonance, 2017, 48 : 1055 - 1074
  • [9] EFFICIENT NUFFT ALGORITHM FOR NON-CARTESIAN MRI RECONSTRUCTION
    Yang, Zhili
    Jacob, Mathews
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 117 - 120
  • [10] Partial fourier shells trajectory for non-cartesian MRI
    Tao, Shengzhen
    Shu, Yunhong
    Trzasko, Joshua D.
    Huston, John, III
    Bernstein, Matt A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (04):