Safe Removal of an Encrusted Nephrostomy Tube Using a Vascular Sheath: A Technique Revisited

被引:0
|
作者
Ammad Farooq
Sanjay Agarwal
Vaughan Jones
机构
[1] Wrexham Maelor Hospital,Department of Radiology
关键词
Nephrostomy; Interventional radiology; Genitourinary; Non-vascular intervention;
D O I
暂无
中图分类号
学科分类号
摘要
With the advent of interventional radiology and the decrease in mortality from chronic ailments, especially malignancy, percutaneous nephrostomy has become a commonly used safe technique for temporary relief of renal tract obstruction or for urinary diversion. However, these are associated with risks of infection, particularly septicaemia, colonisation, and blockage. Another significant complication is difficulty in removal due to encrustation. We describe a useful technique used in our department for the past few years and cite four cases of variable presentation and complexity for removal of an encrusted nephrostomy tube. No mention of this technique was found recent literature. An almost similar technique was described in the 1980s "Pollack and Banner (Radiology 145:203–205, 1982), Baron and McClennan (Radiology 141:824, 1981)". It is possible that experienced operators may have used this technique. We revisit it with pictographic representation, describing its use with currently available equipment, for benefit of operators who are not aware of this technique.
引用
收藏
页码:820 / 823
页数:3
相关论文
共 39 条
  • [1] Safe Removal of an Encrusted Nephrostomy Tube Using a Vascular Sheath: A Technique Revisited
    Farooq, Ammad
    Agarwal, Sanjay
    Jones, Vaughan
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (03) : 820 - 823
  • [2] Lithoclast removal of an encrusted nephrostomy tube
    Mangera, A.
    Mehta, S.
    Hastie, K. J.
    Salim, F.
    Hall, J.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2010, 92 (04) : 353 - 354
  • [3] The use of endo-vascular balloon tamponade technique for the removal of a misplaced nephrostomy tube in the inferior vena cava: A case report
    Al Zahrani, Yousof
    AlHarbi, Sultan R.
    Wiseman, Daniele
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2016, 26 : 179 - 182
  • [4] REMOVAL OF DISRUPTED NEPHROSTOMY TUBE AND URETERAL STENT VIA PERCUTANEOUS WAY IS A SAFE AND EFFICIENT METHOD
    Kural, A.
    Aksit, S.
    Akpinar, H.
    Tufek, I.
    Atug, F.
    JOURNAL OF ENDOUROLOGY, 2009, 23 : A392 - A393
  • [5] Removal of a nephrostomy tube without causing inadvertent dislodgement of a JJ stent: An alternative technique
    Mishra V.C.
    Karim O.M.A.
    International Urology and Nephrology, 2001, 33 (4) : 619 - 619
  • [6] A Novel Technique for Tethered Dialysis Catheter Removal Using the Laser Sheath
    Carrillo, Roger G.
    Garisto, Juan D.
    Salman, Loay
    Merrill, Donna
    Asif, Arif
    SEMINARS IN DIALYSIS, 2009, 22 (06) : 688 - 691
  • [7] Perirectal abscess drainage - A simple modification in technique using a vascular sheath
    D'Costa, H
    Bloor, C
    Maskell, G
    Farrow, R
    CLINICAL RADIOLOGY, 1998, 53 (01) : 78 - 78
  • [8] Immediate sheath removal after PCI using a Femostop® is feasible and safe.: Results of a registry
    Jaspers, L
    Benit, E
    ACTA CARDIOLOGICA, 2003, 58 (06) : 535 - 537
  • [9] Silicone oil removal using vitrectomy machine: A simple and safe technique
    Garodia, VK
    Kulkarni, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06): : 685 - 687
  • [10] Rapid nephrostomy tube placement using a CT-guided, non-fluoroscopic, single stick technique
    Bohlman, ME
    Khazan, R
    Sufi, A
    Regan, F
    JOURNAL OF INTERVENTIONAL RADIOLOGY, 1998, 13 (03): : 101 - 105