Use of intraoperative fluorescein sodium fluorescence to improve the accuracy of tissue diagnosis during stereotactic needle biopsy of high-grade gliomas

被引:0
|
作者
Roberto Rey-Dios
Eyas M. Hattab
Aaron A. Cohen-Gadol
机构
[1] University of Mississippi Medical Center,Department of Neurosurgery
[2] Indiana University School of Medicine,Department of Pathology and Laboratory Medicine
[3] Indiana University School of Medicine,Goodman Campbell Brain and Spine, Department of Neurological Surgery
来源
Acta Neurochirurgica | 2014年 / 156卷
关键词
Fluorescein sodium; Fluorescence; Stereotactic brain biopsy; High-grade glioma;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1071 / 1075
页数:4
相关论文
共 50 条
  • [1] Use of intraoperative fluorescein sodium fluorescence to improve the accuracy of tissue diagnosis during stereotactic needle biopsy of high-grade gliomas
    Rey-Dios, Roberto
    Hattab, Eyas M.
    Cohen-Gadol, Aaron A.
    ACTA NEUROCHIRURGICA, 2014, 156 (06) : 1071 - 1075
  • [2] Cost-effectiveness of sodium fluorescein in high-grade gliomas
    Rustemi, Oriela
    Raneri, Fabio
    Beggio, Giacomo
    Volpin, Lorenzo
    JOURNAL OF NEUROSURGERY, 2020, 133 (05) : 1626 - 1627
  • [3] Relationship between the sodium fluorescein yellow fluorescence boundary and the actual boundary of high-grade gliomas during surgical resection
    Chen, Ze-Bo
    Zhu, Xiao-Peng
    Zheng, Wei
    Xiang, Yan
    Huang, Yong-Kai
    Fang, Hong-Jun
    Deng, Ai-Jun
    Yi, Fu-Rong
    Chen, Hui-Wei
    Han, De-Qing
    Lv, Sheng-Qing
    BRITISH JOURNAL OF NEUROSURGERY, 2024, 38 (04) : 825 - 832
  • [4] Surgery for high-grade gliomas using intraoperative MRI and fluorescence
    Fujii, Masazumi
    NEUROLOGY INDIA, 2018, 66 (03) : 753 - 754
  • [5] Cost-effectiveness of sodium fluorescein in high-grade gliomas Response
    Hansen, Rasmus W.
    Pedersen, Christian B.
    Halle, Bo
    Korshoej, Anders R.
    Schulz, Mette K.
    Kristensen, Bjarne W.
    Poulsen, Frantz R.
    JOURNAL OF NEUROSURGERY, 2020, 133 (05) : 1627 - 1627
  • [6] Use of intraoperative sodium fluorescein for diagnostic tissue biopsy of spinal cord lesions
    Ung, Timothy H.
    Robinson, Leslie C.
    Nevzati, Edin
    Harasaki, Yasuaki
    Ormond, D. Ryan
    Lillehei, Kevin O.
    Witt, Jens-Peter
    Finn, Michael
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2019, 18
  • [7] Clinical effectiveness of sodium fluorescein-guided microsurgery in patients with high-grade gliomas
    Wang, G. -B.
    Wang, W. -X
    Luo, J. -J.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (09) : 3906 - 3913
  • [8] Sodium fluorescein versus 5-aminolevulinic acid to visualize high-grade gliomas
    Molina, Eric Suero
    Brokinkel, Benjamin
    JOURNAL OF NEUROSURGERY, 2020, 133 (05) : 1627 - 1629
  • [9] Study of the biodistribution of fluorescein in glioma-infiltrated mouse brain and histopathological correlation of intraoperative findings in high-grade gliomas resected under fluorescein fluorescence guidance
    Diaz, Roberto Jose
    Dios, Roberto Rey
    Hattab, Eyas M.
    Burrell, Kelly
    Rakopoulos, Patricia
    Sabha, Nesrin
    Hawkins, Cynthia
    Zadeh, Gelareh
    Rutka, James T.
    Cohen-Gadol, Aaron A.
    JOURNAL OF NEUROSURGERY, 2015, 122 (06) : 1360 - 1369
  • [10] Intraoperative Probe-Based Confocal Laser Endomicroscopy in Surgery and Stereotactic Biopsy of Low-Grade and High-Grade Gliomas: A Feasibility Study in Humans
    Pavlov, Vladislav
    Meyronet, David
    Meyer-Bisch, Vincent
    Armoiry, Xavier
    Pikul, Brian
    Dumot, Chloe
    Beuriat, Pierre-Aurelien
    Signorelli, Francesco
    Guyotat, Jacques
    NEUROSURGERY, 2016, 79 (04) : 604 - 611