Noise silencers on discharge lines of steam from power-generating boilers

被引:1
|
作者
Tupov V.B. [1 ]
Chugunkov D.V. [1 ]
机构
[1] Moscow Power Engineering Institute (MEI), Moscow 111250
关键词
Steam; Sound Pressure Level; Safety Valve; Cogeneration Station; Moscow Power Engineer Institute;
D O I
10.1134/S0040601509080072
中图分类号
学科分类号
摘要
The characteristics of well-known designs of steam noise silencers are analyzed. New steam noise silencers designed at Moscow Power Engineering Institute (MEI) are described, and results of tests of them carried out at different facilities are presented. It is shown that the MEI silencer can be used in a wide range of dump steam parameters and be applied in power units for both subcritical and supercritical steam conditions. © 2009 Pleiades Publishing, Ltd.