Simultaneous electrochemical immunosensing of alpha-fetoprotein and prostate specific antigen using a glassy carbon electrode modified with gold nanoparticle-coated silica nanospheres and decorated with Azure A or ferrocenecarboxylic acid

被引:0
|
作者
Junqing Zhao
Zilin Guo
Dexiang Feng
Jinjin Guo
Junchun Wang
Yuzhong Zhang
机构
[1] Anhui Normal University,College of Chemistry and Materials Science, the Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Laboratory of Molecule
[2] Wannan Medical College,Based Materials, Anhui Key Laboratory of Chem
来源
Microchimica Acta | 2015年 / 182卷
关键词
Electrochemical immunosensor; Silica nanoparticles; Gold nanoparticles; Azure A; Ferrocenecarboxylic acid; Differential pulse voltammetry; Immunosensor;
D O I
暂无
中图分类号
学科分类号
摘要
We describe an electrochemical immunosensor for the simultaneous determination of alpha-fetoprotein (AFP) and prostate specific antigen (PSA) via a modified glassy carbon electrode. Silica nanoparticles (200–300 nm i.d.) with good monodispersity and uniform shape were synthesized, and the following species were then consecutively immobilized on their surface: gold nanoparticles (AuNPs; 5–15 nm i.d.), secondary antibody (Ab2) and the redox-probes Azure A or ferrocenecarboxy acid (Fc). In parallel, two types of primary antibodies (Ab1) were co-immobilized on the surface of the dissolved reduced graphene oxide sheets (rGO) that were also decorated with AuNPs. In the presence of antigens (AFP or PSA), the Ab2/Si@AuNPs carrying Azure A and Fc are attached to the AuNP/rGO conjugate via a sandwich type immunoreaction. Differential pulse voltammetry (DPV) was employed to measure the resulting changes in the signal of Fc or Azure A. Two well-resolved oxidation peaks, one at −0.48 V (corresponding to Azure A) and other at + 0.12 V (corresponding to Fc; both vs. SCE) can be observed in the DPV curves. Under optimal conditions, AFP and PSA can be simultaneously determined in the range from 0.01 to 25 ng mL‾1 for AFP, and from 0.012 to 25 ng mL‾1 for PSA. The detection limits are 3.3 pg mL‾1 for AFP and 4.0 pg mL‾1 for PSA (at a signal-to-noise ratio of 3). The method was applied to (spiked) real sample analysis, and the recoveries are within 96.0 and 107.2 % for PSA, and within 100.9 and 105.8 % for AFP, indicating that this dual immunosensor matches the requirements of clinical analysis.
引用
收藏
页码:2435 / 2442
页数:7
相关论文
共 16 条
  • [1] Simultaneous electrochemical immunosensing of alpha-fetoprotein and prostate specific antigen using a glassy carbon electrode modified with gold nanoparticle-coated silica nanospheres and decorated with Azure A or ferrocenecarboxylic acid
    Zhao, Junqing
    Guo, Zilin
    Feng, Dexiang
    Guo, Jinjin
    Wang, Junchun
    Zhang, Yuzhong
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2435 - 2442
  • [2] ELECTROCHEMICAL DETERMINATION OF CAPSAICIN AND SILYMARIN USING A GLASSY CARBON ELECTRODE MODIFIED BY GOLD NANOPARTICLE DECORATED MULTIWALLED CARBON NANOTUBES
    Mpanza, Thabani
    Sabela, Myalowenkosi I.
    Mathenjwa, Sanele S.
    Kanchi, Suvardhan
    Bisetty, Krishna
    ANALYTICAL LETTERS, 2014, 47 (17) : 2813 - 2828
  • [3] Electrochemical immunoassay for carcinoembryonic antigen using gold nanoparticle-graphene composite modified glassy carbon electrode
    Zhu, Lian
    Xu, Lili
    Jia, Ningming
    Huang, Baozhen
    Tan, Liang
    Yang, Sufang
    Yao, Shouzhuo
    TALANTA, 2013, 116 : 809 - 815
  • [4] Bio-synthesized silver nanoparticle modified glassy carbon electrode as electrochemical biosensor for prostate specific antigen detection
    Mandal, Naresh
    Mitra, Raja
    Pramanick, Bidhan
    CARBON TRENDS, 2023, 13
  • [5] Simultaneous voltammetric immunodetection of alpha-fetoprotein and glypican-3 using a glassy carbon electrode modified with magnetite-conjugated dendrimers
    Chikhaliwala, Priyal
    Rai, Rakesh
    Chandra, Sudeshna
    MICROCHIMICA ACTA, 2019, 186 (04)
  • [6] Simultaneous voltammetric immunodetection of alpha-fetoprotein and glypican-3 using a glassy carbon electrode modified with magnetite-conjugated dendrimers
    Priyal Chikhaliwala
    Rakesh Rai
    Sudeshna Chandra
    Microchimica Acta, 2019, 186
  • [7] Electrochemical Zn2+ Detection Using Tannic Acid-Capped Gold Nanoparticle Modified Glassy Carbon Electrode
    Suherman, Alex Lukmanto
    MAKARA JOURNAL OF SCIENCE, 2018, 22 (02) : 95 - 102
  • [8] A glassy carbon electrode modified with graphene nanoplatelets, gold nanoparticles and chitosan, and coated with a molecularly imprinted polymer for highly sensitive determination of prostate specific antigen
    Ma, Ya
    Shen, Xiao-Lei
    Zeng, Qiang
    Wang, Li-Shi
    MICROCHIMICA ACTA, 2017, 184 (11) : 4469 - 4476
  • [9] A glassy carbon electrode modified with graphene nanoplatelets, gold nanoparticles and chitosan, and coated with a molecularly imprinted polymer for highly sensitive determination of prostate specific antigen
    Ya Ma
    Xiao-Lei Shen
    Qiang Zeng
    Li-Shi Wang
    Microchimica Acta, 2017, 184 : 4469 - 4476
  • [10] Simultaneous and sensitive detection of dopamine and uric acid using a poly(L-methionine)/gold nanoparticle-modified glassy carbon electrode
    Ojani, Reza
    Raoof, Jahan-Bakhsh
    Maleki, Ali Asghar
    Safshekan, Saeid
    CHINESE JOURNAL OF CATALYSIS, 2014, 35 (03) : 423 - 429