Protocol for uncertainty assessment of half-lives

被引:0
|
作者
S. Pommé
J. Camps
R. Van Ammel
J. Paepen
机构
[1] Institute for Reference Materials and Measurements,European Commission, Joint Research Centre
关键词
Uncertainty Budget; Uncertainty Component; Uncertainty Assessment; Radiation Isotope; Exponential Decay Curve;
D O I
暂无
中图分类号
学科分类号
摘要
The apparent tendency to underestimate the uncertainty of experimentally determined half-life values of radionuclides is discussed. It is argued that the uncertainty derived from a least-squares analysis of a decay curve is prone to error. As it is quite common for a series of activity measurement results to be autocorrelated, the prerequisite of randomness of data for common statistical tests to apply is not fulfilled. In this work, an alternative data analysis method is applied that leads to a more realistic uncertainty budget. The uncertainty components are being subdivided in three categories according to the relative frequency at which they occur, an appropriate uncertainty propagation formula applied and then the total uncertainty obtained from an independent sum. An attempt is made to apply the protocol to problematic cases in literature, yet it is clear that the reporting is usually incomplete for a full uncertainty analysis. Suggestions are made for a concise but more complete reporting style, for the sake of traceability.
引用
收藏
页码:335 / 339
页数:4
相关论文
共 50 条
  • [1] Protocol for uncertainty assessment of half-lives
    Pomme, S.
    Camps, J.
    Van Ammel, R.
    Paepen, J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (02) : 335 - 339
  • [2] Uncertainty in estimated half-lives of PCBS in humans: Impact on exposure assessment
    Shirai, JH
    Kissel, JC
    SCIENCE OF THE TOTAL ENVIRONMENT, 1996, 187 (03) : 199 - 210
  • [3] Half-lives
    Rawdon, M
    CHEMICAL & ENGINEERING NEWS, 1996, 74 (38) : 4 - 4
  • [4] All half-lives are wrong, but some half-lives are useful
    Wright, JG
    Boddy, AV
    CLINICAL PHARMACOKINETICS, 2001, 40 (04) : 237 - 244
  • [5] All Half-Lives Are Wrong, But Some Half-Lives Are Useful
    James G. Wright
    Alan V. Boddy
    Clinical Pharmacokinetics, 2001, 40 : 237 - 244
  • [6] Anniversaries and half-lives
    Bawden, David
    JOURNAL OF DOCUMENTATION, 2007, 63 (03) : 297 - 298
  • [7] Half-lives slashed
    不详
    TCE, 2006, (783): : 16 - 16
  • [8] PRECISION MEASUREMENT OF HALF-LIVES
    SILVER, LM
    PHYSICAL REVIEW, 1949, 76 (04): : 589 - 589
  • [9] SPONTANEOUS FISSION HALF-LIVES
    SASAKAWA, T
    YASUNO, M
    PROGRESS OF THEORETICAL PHYSICS, 1958, 20 (03): : 315 - 326
  • [10] HALF-LIVES OF SOME RADIONUCLIDES
    LAGOUTINE, F
    LEGRAND, J
    BAC, C
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1978, 29 (4-5): : 269 - 272