A new design of passive air condition integrated with solar chimney for hot arid region of Egypt

被引:0
|
作者
A. S. H. Abdallah
机构
[1] Assiut University,Department of Architecture, Faculty of Engineering
关键词
Passive air condition; Solar chimney; Occupant comfort; Thermal sensation;
D O I
暂无
中图分类号
学科分类号
摘要
Housing in Egypt consumes high energy for cooling. Bioclimatic building design is one of the strategies of sustainable development. This study aims to investigate the thermal performance and indoor air quality of solar chimney with passive cooling wind tower (SCPCW) on occupant’s comfort. Thermal performance of a full-scale SCPCW was experimentally investigated. The passive cooling design is integrated on the ceiling of 30 m2 test house. Monitoring of indoor environment was carried out over a period of 2 months in the summer season (August, September and early October) with a 2-min interval in order to calculate thermal comfort sensation, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied. The results show that outlet air temperature from the wind tower is 27.3 °C. Also, the calculated PMV is within the recommended range (− 0.5 < PMV < + 0.5). This indicates that occupants remain satisfied with indoor thermal environment after using the passive cooling system and the temperature difference between outdoor and indoor is approximately 8 °C. The system achieves the acceptable air flow rate with average 450 ppm for CO2 concentration during daytime. The results of this research provide information of the system applicability in the climate of Assiut during daytime in order to develop and install on top of real residential buildings in New Assiut, Egypt.
引用
收藏
页码:2611 / 2618
页数:7
相关论文
共 50 条
  • [1] A new design of passive air condition integrated with solar chimney for hot arid region of Egypt
    Abdallah, A. S. H.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2019, 16 (06) : 2611 - 2618
  • [2] Occupant Comfort and Indoor Temperature Reduction by Using Passive Air Conditioning System with Solar Chimney Concept in Hot Arid Climate
    Abdallah, Amr Sayed Hassan
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1100 - 1107
  • [3] Passive cooling of buildings by using integrated earth to air heat exchanger and solar chimney
    Maerefat, M.
    Haghighi, A. P.
    RENEWABLE ENERGY, 2010, 35 (10) : 2316 - 2324
  • [4] New passive thermal comfort system using three renewable energies: Wind catcher, solar chimney and earth to air heat exchanger integrated toreal-scaletest room in arid region (Experimental study)
    Sakhri, Nasreddine
    Moussaoui, Abdeljabar
    Menni, Younes
    Sadeghzadeh, Milad
    Ahmadi, Mohammad Hosein
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (02) : 2177 - 2194
  • [5] Experimental study of passive air condition system integrated into a single room in Assiut, Egypt
    Abdallah, Amr Sayed Hassan
    ENERGY AND BUILDINGS, 2017, 153 : 564 - 570
  • [6] New design for solar chimney with integrated windcatcher for space cooling and ventilation
    Moosavi, Leila
    Zandi, Majid
    Bidi, Mokhtar
    Behroozizade, Ehsan
    Kazemi, Iman
    BUILDING AND ENVIRONMENT, 2020, 181 (181)
  • [7] Performance assessment of solar chimney coupled with earth-to-air heat exchanger: A passive alternative for an indoor swimming pool ventilation in hot-arid climate
    Pouranian, Fatemeh
    Akbari, Habibollah
    Hosseinalipour, S. M.
    APPLIED ENERGY, 2021, 299
  • [8] A SOLAR PASSIVE BUILDING FOR HOT ARID ZONES IN INDIA
    BANSAL, NK
    SODHA, MS
    SHARMA, AK
    RAKSHIT, R
    ENERGY CONVERSION AND MANAGEMENT, 1991, 32 (01) : 1 - 9
  • [9] Solar chimney combined with earth to-air heat exchanger for passive cooling of residential buildings in hot areas
    Serageldin, Ahmed A.
    Abdeen, Ahmed
    Ahmed, Mostafa M. S.
    Radwan, Ali
    Shmroukh, Ahmed N.
    Ookawara, Shinichi
    SOLAR ENERGY, 2020, 206 (206) : 145 - 162
  • [10] Solar chimney integrated with passive evaporative cooler applied on glazing surfaces
    Al Touma, Albert
    Ghali, Kamel
    Ghaddar, Nesreen
    Ismail, Nagham
    ENERGY, 2016, 115 : 169 - 179