Fractionation of persistent organic pollutants in fish oil by high-performance liquid chromatography on a 2-(1-pyrenyl)ethyl silica column

被引:0
|
作者
X. Ortiz
R. Martí
M. J. Montaña
M. Gasser
L. Margarit
F. Broto
J. Díaz-Ferrero
机构
[1] Institut Químic de Sarrià (Ramon Llull University),Analytical Chemistry Department
来源
关键词
Persistent organic pollutants; Dioxins; Polychlorinated biphenyls; Polybrominated diphenyl ethers; Organochlorine pesticides; Fish oil;
D O I
暂无
中图分类号
学科分类号
摘要
The analysis of persistent organic pollutants in foodstuffs has become necessary for control of their levels in products for human and animal consumption. These analytical procedures usually require a fractionation step in order to separate the different families of pollutants to avoid interferences during the instrumental determination. In this study the separation was carried out on a 2-(1-pyrenyl)ethyl silica column, where analyte fractionation was based on differences in planarity and aromaticity. The fractionation of several types of persistent organic pollutants found in fish oil samples was studied; the pollutants included polychlorinated dibenzo-p-dioxins and dibenzofurans, polychlorinated biphenyls, polybrominated diphenyl ethers, and some organochlorine pesticides. Fractions were analyzed by high-resolution gas chromatography with electron-capture detection and high-resolution gas chromatography–high resolution mass spectroscopy. Finally, the whole method (including the purification, fractionation, and instrumental determination steps) was validated and successfully applied to the analysis of several samples of fish oil.
引用
收藏
页码:985 / 994
页数:9
相关论文
共 50 条
  • [1] Fractionation of persistent organic pollutants in fish oil by high-performance liquid chromatography on a 2-(1-pyrenyl)ethyl silica column
    Ortiz, X.
    Marti, R.
    Montana, M. J.
    Gasser, M.
    Margarit, L.
    Broto, F.
    Diaz-Ferrero, J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) : 985 - 994
  • [2] ISOLATION OF TOXIC POLYCHLORINATED-BIPHENYLS BY ELECTRON-DONOR ACCEPTOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A 2-(1-PYRENYL)ETHYLDIMETHYLSILYLATED SILICA COLUMN
    HAGLUND, P
    ASPLUND, L
    JARNBERG, U
    JANSSON, B
    JOURNAL OF CHROMATOGRAPHY, 1990, 507 : 389 - 398
  • [3] [2-(1-PYRENYL)ETHYL]SILYL SILICA PACKING MATERIAL FOR LIQUID-CHROMATOGRAPHIC SEPARATION OF FULLERENES
    KIMATA, K
    HOSOYA, K
    ARAKI, T
    TANAKA, N
    JOURNAL OF ORGANIC CHEMISTRY, 1993, 58 (01): : 282 - 283
  • [4] Separation of planar organic contaminants by pyrenyl-silica high-performance liquid chromatography
    Wells, DE
    Echarri, I
    McKenzie, C
    JOURNAL OF CHROMATOGRAPHY A, 1995, 718 (01) : 107 - 118
  • [5] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOGENIC POLYAMINES USING 2-(1-PYRENYL)ETHYL CHLOROFORMATE AS A NEW FLUOROGENIC DERIVATIZING REAGENT
    CICHY, MA
    STEGMEIER, DL
    VEENING, H
    BECKER, HD
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (01): : 15 - 21
  • [6] FRACTIONATION OF SILICA-GEL PARTICLES AND COLUMN PREPARATION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ASKEROV, DB
    TARASOV, VF
    TISHCHENKO, AI
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1978, 33 (09): : 1294 - 1296
  • [7] Fractionation of chlorinated and brominated persistent organic pollutants in several food samples by pyrenyl-silica liquid chromatography prior to GC-MS determination
    Gómara, B
    García-Ruiz, C
    González, MJ
    Marina, ML
    ANALYTICA CHIMICA ACTA, 2006, 565 (02) : 208 - 213
  • [8] Some considerations about the separation of polyaromatic hydrocarbons on a 2-(1-pyrenyl) ethyl dimethylsilica-HPLC column
    Nerin, C
    Domeno, C
    Fernandez, P
    Cacho, J
    QUIMICA ANALITICA, 1998, 17 (02): : 75 - 81
  • [9] ISOLATION OF MONO-ORTHO AND NON-ORTHO POLYCHLORINATED-BIPHENYLS FROM BIOLOGICAL SAMPLES BY ELECTRON-DONOR ACCEPTOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A 2-(1-PYRENYL)ETHYLDIMETHYLSILYLATED SILICA COLUMN
    HAGLUND, P
    ASPLUND, L
    JARNBERG, U
    JANSSON, B
    CHEMOSPHERE, 1990, 20 (7-9) : 887 - 894
  • [10] New fluorescent reagent 4-(1-pyrenyl)butyl 2-(piperidino)ethanesulfonate for liquid chromatography
    Kou, Hwang-Shang
    Wu, Hsin-Lung
    Chen, Su-Hwei
    Wu, Shou-Mei
    Chinese Pharmaceutical Journal, 1999, 51 (06): : 385 - 396