Robust segmented regression: application to oxygen uptake plateau identification

被引:0
|
作者
Alessandro J. Q. Sarnaglia
Fabio A. Fajardo Molinares
Paulo H. S. M. Azevedo
机构
[1] UFES,LECON and DasLab, Statistics Department
[2] UNIFESP,GEPEFEX, Human Movement Science Department
关键词
Bootstrap; Oxygen uptake; Robust estimation; Segmented regression;
D O I
暂无
中图分类号
学科分类号
摘要
Recently, segmented regression has been utilized as a “working” model for a bootstrap test to detect true oxygen uptake plateau. This approach employs an iterative procedure based on least squares to fit the model. However, it is widely acknowledged that the least squares approach is highly sensitive to outliers, often yielding inefficient estimates. This paper proposes an alternative iterative method by substituting the least squares step with a M-estimator step. Leveraging the robust features of M-estimators, the proposed method is expected to exhibit resilience against outliers. To empirically investigate the performance of the proposed method, a Monte Carlo simulation study is conducted. For comparison purposes, the classical iterative method is also considered. The results indicate that, in uncontaminated scenarios, both methods exhibit similar behavior, with the classical method presenting a slightly superior performance. However, in contaminated cases, the classical method is highly deteriorated, with significant bias and root mean squared error, while the proposed method demonstrates much better performance. Both methods are employed to fit the “working” 3-segment regression model and perform a plateau test on apparently contaminated oxygen uptake data. The results reveal that, due to the presence of outliers, the classical method produces inflated estimates for the error variance and larger standard errors for all parameters, in comparison to the proposed method. Moreover, the plateau test conducted using the classical (robust) method leads to the rejection (confirmation) of a plateau of oxygen uptake for the same data. Overall, these findings highlight the superiority of the proposed method in handling outliers.
引用
收藏
页码:625 / 648
页数:23
相关论文
共 50 条
  • [1] Robust segmented regression: application to oxygen uptake plateau identification
    Sarnaglia, Alessandro J. Q.
    Molinares, Fabio A. Fajardo
    Azevedo, Paulo H. S. M.
    ENVIRONMENTAL AND ECOLOGICAL STATISTICS, 2023, 30 (04) : 625 - 648
  • [2] Oxygen Uptake Plateau Diagnosis Using a New Developed Segmented Regression Estimation Method for Autocorrelated Data
    Patricio, Silvio Cabral
    Sarnaglia, Alessandro J. Q.
    Molinares, Fabio A. Fajardo
    Azevedo, Paulo H. S. M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (11) : 3281 - 3289
  • [3] Robust fuzzy linear regression and application for contact identification
    Oussalah, M
    De Schutter, J
    INTELLIGENT AUTOMATION AND SOFT COMPUTING, 2002, 8 (01): : 31 - 39
  • [4] APPLICATION OF ROBUST REGRESSION METHODS TO FAULT IDENTIFICATION IN ROTATING MACHINERY
    Pennacchi, R.
    Chatterton, S.
    Ricci, R.
    Vania, A.
    8TH IFTOMM INTERNATIONAL CONFERENCE ON ROTOR DYNAMICS (IFTOMM ROTORDYNAMICS 2010), 2010, : 376 - 383
  • [5] APPLICATION OF SEGMENTED REGRESSION FOR K SETS OF DATA
    GBUR, EE
    BIOMETRICS, 1978, 34 (04) : 731 - 731
  • [6] Oxygen uptake plateau occurrence depends on oxygen kinetics and oxygen deficit accumulation
    Niemeyer, Max
    Leithaeuser, Renate
    Beneke, Ralph
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2019, 29 (10) : 1466 - 1472
  • [7] Robust identification of switched regression models
    Domlan, E.
    Huang, B.
    Ragot, J.
    Maquin, D.
    IET CONTROL THEORY AND APPLICATIONS, 2009, 3 (12): : 1578 - 1590
  • [8] Validity of oxygen uptake cut-off criteria in plateau identification during horizontal treadmill running
    Marsh, Clare E.
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2019, 59 (01): : 10 - 16
  • [9] Oxygen uptake efficiency plateau: physiology and reference values
    Xing-Guo Sun
    James E. Hansen
    William W. Stringer
    European Journal of Applied Physiology, 2012, 112 : 919 - 928
  • [10] Oxygen uptake plateau: calculation artifact or physiological reality?
    Max Niemeyer
    Tobias G. J. Bergmann
    Ralph Beneke
    European Journal of Applied Physiology, 2020, 120 : 231 - 242