Key comparisons of the VNIIM and BIPM voltage standards

被引:0
|
作者
A. S. Katkov
S. Solve
机构
[1] Mendeleev All-Russia Research Institute of Metrology (VNIIM),
[2] International Bureau of Weights and Measures (BIPM),undefined
来源
Measurement Techniques | 2012年 / 54卷
关键词
voltage standard; Josephson effect; voltage measure; transfer standard;
D O I
暂无
中图分类号
学科分类号
摘要
The results of key comparisons of the national primary standard of Russia for the unit of electrical voltage, the volt, at the Mendeleev Institute of Metrology (VNIIM) with the Josephson effect voltage standard at the BIPM are reported. For these measurements, VNIIM provided a voltage measure based on the Josephson effect with a nominal output voltage of 10 V. Measurements were made with apparatus from the BIPM voltage standard. The VNIIM voltage measure is planned for use as a transfer standard for comparison with national standards for the volt. The comparisons indicate a high degree of equivalence of the compared VNIIM and BIPM primary standards with a relative combined standard uncertainty of 2·10–10 at 10 V.
引用
收藏
页码:1313 / 1318
页数:5
相关论文
共 50 条
  • [1] KEY COMPARISONS OF THE VNIIM AND BIPM VOLTAGE STANDARDS
    Katkov, A. S.
    Solve, S.
    [J]. MEASUREMENT TECHNIQUES, 2012, 54 (11) : 1313 - 1318
  • [2] Comparison of the Josephson Voltage Standards of the VNIIM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Katkov, Alexander
    [J]. METROLOGIA, 2011, 48
  • [3] Comparison of the Josephson Voltage Standards of the NMC, A*STAR and the BIPM (part of the ongoing BIPM key comparisons BIPM.EM-K10.a and BIPM.EM-K10.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Zhou, Yinzhu
    Lee, Jinni
    Chua, Sze Wey
    [J]. METROLOGIA, 2011, 48
  • [4] Comparison of the Josephson voltage standards of VNIIM and PTB
    Behr, R
    Niemeyer, J
    Katkov, A
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 251 - 252
  • [5] Comparison of the Josephson Voltage Standards of the INTI and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.a)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Iuzzolino, R.
    Tonina, A.
    [J]. METROLOGIA, 2012, 49
  • [6] Comparison of the Josephson voltage standards of VNIIM and PTB
    Behr, R
    Niemeyer, J
    Katkov, AS
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) : 203 - 205
  • [7] Comparison of the Josephson Voltage Standards of the MSL and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Christian, Laurie
    [J]. METROLOGIA, 2012, 49
  • [8] Comparison of the Josephson Voltage Standards of the NIM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Yuan, Gao
    Li Honghui
    Wang Zengmin
    [J]. METROLOGIA, 2014, 51
  • [9] Comparison of the Josephson Voltage Standards of the CENAM and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Aviles, D.
    Navarrete, E.
    Hernandez, D.
    [J]. METROLOGIA, 2012, 49
  • [10] Comparison of the Josephson Voltage Standards of the SMD and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Holiastou, M.
    Flouda, I.
    [J]. METROLOGIA, 2010, 47