An equivalent source to describe realistic synchrotron hard X-rays

被引:0
|
作者
Hui Jiang
Shuai Yan
Hua Wang
Yi Zheng
Zhaohui Dong
Aiguo Li
机构
[1] Chinese Academy of Sciences,Shanghai Synchrotron Radiation Facility, Shanghai Institute of Applied Physics
来源
Applied Physics B | 2016年 / 122卷
关键词
Particle Swarm Optimization; Optical Element; Detection Plane; Equivalent Source; Double Crystal Monochromator;
D O I
暂无
中图分类号
学科分类号
摘要
An equivalent source model was used to describe realistic third-generation synchrotron hard X-rays to avoid simplifying the light source model excessively or introducing too many variables from optical elements into quantitative calculation. By using particle swarm optimization, through secondary source with different slit apertures, the direct beam diffraction patterns on the detection plane propagated from the simulated equivalent source were in great agreement with the measured patterns. This study is hoped to reduce the difficulty of calculation and improve the accuracy of various coherent imaging or metrology measurements.
引用
收藏
相关论文
共 50 条
  • [1] An equivalent source to describe realistic synchrotron hard X-rays
    Jiang, Hui
    Yan, Shuai
    Wang, Hua
    Zheng, Yi
    Dong, Zhaohui
    Li, Aiguo
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (11):
  • [2] Multibeam ptychography with synchrotron hard X-rays
    Hirose, Makoto
    Higashino, Takaya
    Ishiguro, Nozomu
    Takahashi, Yukio
    [J]. OPTICS EXPRESS, 2020, 28 (02) : 1216 - 1224
  • [3] Synchrotron x-rays from a tabletop source
    Les, Caren B.
    [J]. PHOTONICS SPECTRA, 2011, 45 (01) : 14 - 14
  • [4] TUNABLE, SHORT PULSE HARD X-RAYS FROM A COMPACT LASER SYNCHROTRON SOURCE
    SPRANGLE, P
    TING, A
    ESAREY, E
    FISHER, A
    [J]. JOURNAL OF APPLIED PHYSICS, 1992, 72 (11) : 5032 - 5038
  • [5] A GUINIER CAMERA FOR X-RAYS FROM A SYNCHROTRON SOURCE
    ARNOLD, H
    KOSTEN, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 208 (1-3): : 599 - 601
  • [6] MEASUREMENT OF THE POLARIZATION OF X-RAYS FROM A SYNCHROTRON SOURCE
    MATERLIK, G
    SUORTTI, P
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1984, 17 (FEB) : 7 - 12
  • [7] Hard x-rays from a tabletop all-laser-driven synchrotron light source
    Umstadter, Donald P.
    [J]. ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS IV, 2015, 9590
  • [8] Synchrotron-based imaging and tomography with hard X-rays
    Rau, C.
    Crecea, V.
    Liu, W.
    Richter, C.-P.
    Peterson, K. M.
    Jemian, P. R.
    Neuhaeusler, U.
    Schneider, G.
    Yu, X.
    Braun, P. V.
    Chiang, T.-C.
    Robinson, I. K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2): : 850 - 854
  • [9] HARD X-RAYS
    Coolidge, W. D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1915, 2 (06) : 723 - 725
  • [10] LASER SYNCHROTRON-RADIATION AS A COMPACT SOURCE OF TUNABLE, SHORT-PULSE HARD X-RAYS
    ESAREY, E
    SPRANGLE, P
    TING, A
    RIDE, SK
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 331 (1-3): : 545 - 549