Right ventricular outflow tract septal pacing versus apical pacing: A prospective, randomized, single-blind 5-years follow-up study of ventricular lead performance and safety

被引:0
|
作者
Yuan-hong Liang
Lie Liu
Dong-li Chen
Chun-ying Lin
Hong-wen Fei
Si-lin Chen
Shu-lin Wu
机构
[1] Guangdong Academy of Medicine Science,Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital
关键词
right ventricular outflow tract setptum septal pacing; follow-up; lead performance;
D O I
暂无
中图分类号
学科分类号
摘要
Lead placement for ventricular pacing variably impacts the physiological benefit of the patient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal pacing in patients with bradyarrhythmia in South China over 60-month follow-up. Totally, 192 patients (108 males, and 84 females, 63±21 years old) with bradyarrhythmia were randomly divided into two groups. The right ventricular outflow tract septum (RVOTs) group had lead placement near the septum (n=97), while the right ventricular apex (RVA) group had a traditional apical placement (n=95). RV septal lead positioning was achieved with a specialized stylet and confirmed using fluoroscopic projection. All patients were followed up for 60 months. Follow-up assessment included stimulation threshold, R-wave sensing, lead impedance and lead complications. The time of electrode implantation in both the ROVTs and RVA groups were significantly different (4.29±0.61 vs. 2.16±0.22 min; P=0.009). No differences were identified in threshold, impedance or R-wave sensing between the two groups at 1st, 12th, 36th and 60th month during the follow-up period. No occurrence of electrode displacement, increased pacing threshold or inadequate sensing was found. The long-term active fixation ventricular electrode performance in RVOTs group was similar to that in RVA group. RVOTs pacing near the septum using active fixation electrodes may provide stability during long-term follow-up period.
引用
收藏
页码:858 / 861
页数:3
相关论文
共 40 条
  • [1] Right Ventricular Outflow Tract Septal Pacing versus Apical Pacing: A Prospective, Randomized, Single-blind 5-Years Follow-up Study of Ventricular Lead Performance and Safety
    梁远红
    刘烈
    陈东骊
    林纯莹
    费洪文
    陈泗林
    吴书林
    Current Medical Science, 2015, (06) : 858 - 861
  • [2] Right ventricular outflow tract septal pacing versus apical pacing: A prospective, randomized, single-blind 5-years follow-up study of ventricular lead performance and safety
    Liang, Yuan-hong
    Liu, Lie
    Chen, Dong-li
    Lin, Chun-ying
    Fei, Hong-wen
    Chen, Si-lin
    Wu, Shu-lin
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2015, 35 (06) : 858 - 861
  • [3] Right Ventricular Outflow Tract Septal Pacing versus Apical Pacing: A Prospective, Randomized, Single-blind 5-Years Follow-up Study of Ventricular Lead Performance and Safety
    梁远红
    刘烈
    陈东骊
    林纯莹
    费洪文
    陈泗林
    吴书林
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2015, 35 (06) : 858 - 861
  • [4] Long-term follow-up of ventricular lead performance and safety with right ventricular septal pacing compared with apical pacing
    Lin, C. Y.
    Liu, L.
    Chen, D. L.
    Fei, H. W.
    Liang, Y. H.
    Chen, S. L.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2010, 12 (0A) : S29 - S29
  • [5] Right Ventricular Outflow Tract Septal Pacing: Long-Term Follow-Up of Ventricular Lead Performance
    Medi, Caroline
    Mond, Harry G.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (02): : 172 - 176
  • [6] Is right ventricular outflow tract pacing superior to right ventricular apex pacing? A long-term follow-up study
    Gong, Xue
    Su, Yangang
    Liang, Yixiu
    Chen, Songwen
    Pan, Wenzhi
    Liu, Shaowen
    Shen, Hong
    Ge, Junbo
    Shu, Xianhong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (03): : 5189 - 5195
  • [7] EFFECTIVENESS OF RIGHT VENTRICULAR SEPTAL PACING VERSUS RIGHT VENTRICULAR APICAL PACING IN PATIENTS REQUIRING PERMANENTPACEMAKER IMPLANTATION: A COMPARATIVE, SHORT TERM FOLLOW-UP STUDY
    Kotwade, Krishnadas
    Jagannatham, N.
    Iqbal, Raja Suhail
    Dash, Pravat Kumar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 143 - 143
  • [8] Is right ventricular outflow tract pacing superior to right ventricular apex pacing?: long-term echocardiographic follow-up results
    Gong, X.
    Shu, X. H.
    Su, Y. G.
    Liang, Y. X.
    Chen, S. W.
    Zhou, N. W.
    Liu, S. W.
    Ge, J. B.
    EUROPEAN HEART JOURNAL, 2015, 36 : 48 - 49
  • [9] Septal versus apical pacing sites in permanent right ventricular pacing: The multicentre prospective SEPTAL-PM study
    Galand, Vincent
    Martins, Raphael P.
    Donal, Erwan
    Behar, Nathalie
    Crocq, Christophe
    Soulie, Gaelle Gresis
    Degand, Bruno
    Garcia, Rodrigue
    Solnon, Aude
    Lande, Gilles
    Probst, Vincent
    Marjaneh, Fatemi
    Mansourati, Jacques
    Dupuis, Jean-Marc
    Laviolle, Bruno
    Leclercq, Christophe
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2022, 115 (05) : 288 - 294
  • [10] RIGHT VENTRICULAR HIGH SEPTAL PACING VS. RIGHT VENTRICULAR APICAL PACING FOLLOWING AV NODE ABLATION: 20 YEARS FOLLOW UP
    Eysenck, William
    Veasey, Rick
    Gallagher, Angela
    Jouhra, Fadi
    Patel, Nikhil
    Furniss, Steve
    Sulke, Neil
    HEART, 2017, 103 : A31 - A31