Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigs

被引:0
|
作者
Nasreddin D. Abolmaali
Volker Hietschold
Steffen Appold
Wolfgang Ebert
Thomas J. Vogl
机构
[1] Institute for Diagnostic and Interventional Radiology,
[2] Johann Wolfgang Goethe University,undefined
[3] Theodor-Stern-Kai 7,undefined
[4] 60590 Frankfurt am Main,undefined
[5] Germany,undefined
[6] Institute and City Hospital for Radiological Diagnostics,undefined
[7] Carl Gustav Carus University,undefined
[8] Fetscherstrasse 74,undefined
[9] 01307 Dresden,undefined
[10] Germany,undefined
[11] Clinic and City Hopsital for Radiotherapy and Radiological Oncology,undefined
[12] Carl Gustav Carus University,undefined
[13] Fetscherstrase 74,undefined
[14] 01307 Dresden,undefined
[15] Germany,undefined
[16] Research Laboratories of Schering AG,undefined
[17] 13342 Berlin,undefined
[18] Germany,undefined
来源
European Radiology | 2002年 / 12卷
关键词
Magnetic resonance angiography Contrast material Pulmonary arteries Animal studies Intravascular contrast agent;
D O I
暂无
中图分类号
学科分类号
摘要
The goal of this study was visualisation and quality assessment of the pulmonary arteries in pigs with modified navigator-echo magnetic resonance angiography using an intravascular contrast agent. Five sedated pigs were examined in a clinical 1.5-T system with modified three-dimensional navigator-echo magnetic resonance angiography (slice thickness 3 mm, pixel size 2.4×1.8 mm2) to evaluate the pulmonary arteries. Using a phased-array four-element thorax coil the entire thorax was scanned before and after intravenous infusion of a gadolinium-based intravascular contrast agent. Assessment of image quality, enhancement-related contrast-to-noise ratio (CNR) measurements and improvement of visibility of peripheral pulmonary vessels was performed. Improvement of quality using Gadomer-17 was found for smaller vessels; pulmonary trunks and the main pulmonary arteries were sufficiently imaged without enhancement. Mean rise of CNR measured in the pulmonary trunks was 28.64% (P=0.0002), mean rise of CNR in the main pulmonary arteries and the segmental arteries were 79.6% and 148.2%, respectively. Mean distance between the visible peripheral end of 60 sub-segmental arteries and the inner thoracic wall was 12.2±0.4 mm, and was significantly (P=0.00002) reduced after contrast infusion to 8.0±0.4 mm. The combination of inherent flow sensitivity of navigator-echo angiography and Gadomer-17 proved effective for imaging of the pulmonary arteries. In contrast to standard contrast-enhanced pulmonary MRA studies, breath holding is not required. Further studies and the evaluation of findings of patients suffering from pulmonary embolism are needed to evaluate the possible benefits of a higher spatial resolution which is achievable using navigator-echo techniques in contrast to the higher temporal resolution of ultra-fast pulmonary MRA.
引用
收藏
页码:692 / 697
页数:5
相关论文
共 50 条
  • [1] Gadomer-17-enhanced 3D navigator-echo MR angiography of the pulmonary arteries in pigs
    Abolmaali, ND
    Hietschold, V
    Appold, S
    Ebert, W
    Vogl, TJ
    EUROPEAN RADIOLOGY, 2002, 12 (03) : 692 - 697
  • [2] Gadomer-17 enhanced navigator-echo MRA: Experimental study and initial results
    Abolmaali, ND
    Hietschold, V
    Appold, S
    Ebert, W
    Vogl, TJ
    ACADEMIC RADIOLOGY, 2002, 9 : S401 - S403
  • [3] 3D MR angiography of pulmonary arteries using realtime navigator gating and magnetization preparation
    Wang, Y
    Rossman, PJ
    Grimm, RC
    Wilman, AH
    Riederer, SJ
    Ehman, RL
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 579 - 587
  • [4] 3D navigator echo MR coronary angiography (MRCA) in detecting stenoses of major epicardial coronary arteries
    Sardanelli, F
    Parodi, RC
    Molinari, G
    Guglielmino, G
    Rescinito, G
    Caponnetto, S
    RADIOLOGY, 1997, 205 : 51 - 51
  • [5] 3D gadolinium-enhanced MR angiography of the carotid arteries
    Cloft, HJ
    Murphy, KJ
    Prince, MR
    Brunberg, JA
    MAGNETIC RESONANCE IMAGING, 1996, 14 (06) : 593 - 600
  • [6] Dynamic 3D MR angiography of the pulmonary arteries in under four seconds
    Goyen, M
    Laub, G
    Ladd, ME
    Debatin, JF
    Barkhausen, J
    Truemmler, KH
    Bosk, S
    Ruehm, SG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) : 372 - 377
  • [7] Value of contrast-enhanced 3D MR angiography of the renal arteries
    Hany, TF
    Pfammatter, T
    Schmidt, M
    Leung, DA
    Debatin, JF
    RADIOLOGE, 1997, 37 (07): : 547 - 553
  • [8] Value of contrast-enhanced 3D MR angiography of the renal arteries
    T. F. Hany
    T. Pfammatter
    Michaela Schmidt
    D. A. Leung
    J. F. Debatin
    Der Radiologe, 1997, 37 : 547 - 553
  • [9] Unenhanced and Gd-enhanced navigator echo MR coronary angiography in visualizing distal segments of coronary arteries
    Parodi, RC
    Sardanelli, F
    Zandrino, F
    Molinari, G
    Basso, M
    Masperone, MA
    RADIOLOGY, 1997, 205 : 58 - 58
  • [10] Repeated 3D coronary MR angiography with navigator echo gating: Technical quality and consistency of image interpretation
    Ikonen, AEJ
    Manninen, HI
    Vainio, P
    Hirvonen, TPJ
    Vanninen, RL
    Matsi, PJ
    Hartikainen, JEK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (03) : 375 - 381