Batch-Type Detection Cell Using a Peroxyoxalate Chemiluminescence System for Capillary Electrophoresis

被引:0
|
作者
Kazuhiko Tsukagoshi
Miwa Otsuka
Masahiko Hashimoto
Riichiro Nakajima
Kazuo Kondo
机构
[1] Faculty of Engineering,Department of Chemical Engineering and Materials Science
[2] Doshisha University,undefined
来源
Analytical Sciences | 1999年 / 15卷
关键词
Capillary electrophoresis; chemiluminescence; peroxyoxalate; optical fiber; batch-type; -amino acid;
D O I
暂无
中图分类号
学科分类号
摘要
A batch-type chemiluminescence detection cell using a peroxyoxalate system was easily combined with capillary elec-trophoresis equipment; the device was operated without any tedious procedures. Peroxyoxalate reagents and hydrogen peroxide were examined in detail concerning their usage and concentration with the cell. Fluorescence-labeled a -amino acids showed the detection limits of 10–100 nM order (S/N=3), which were approximately 2 or 3 orders of magnitude lower than those obtained with the absorbance. A mixture sample of the labeled a -amino acids was successfully separated and detected.
引用
收藏
页码:1257 / 1260
页数:3
相关论文
共 50 条
  • [1] Batch-type detection cell using a peroxyoxalate chemiluminescence system for capillary electrophoresis
    Dept. of Chem. Eng. and Mat. Science, Faculty of Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321, Japan
    Anal. Sci., 12 (1257-1260):
  • [2] Batch-type detection cell using a peroxyoxalate chemiluminescence system for capillary electrophoresis
    Tsukagoshi, K
    Otsuka, M
    Hashimoto, M
    Nakajima, R
    Kondo, K
    ANALYTICAL SCIENCES, 1999, 15 (12) : 1257 - 1260
  • [3] Batch-type chemiluminescence detection cell for sensitization and simplification of capillary electrophoresis
    Tsukagoshi, K
    Nakamura, T
    Nakajima, R
    ANALYTICAL CHEMISTRY, 2002, 74 (16) : 4109 - 4116
  • [4] Consideration on peak shape in a batch-type chemiluminescence detection cell for capillary electrophoresis
    Tsukagoshi, K
    Otsuka, M
    Shikata, Y
    Nakajima, R
    JOURNAL OF CHROMATOGRAPHY A, 2001, 930 (1-2) : 165 - 169
  • [5] PEROXYOXALATE CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS
    WU, NA
    HUIE, CW
    JOURNAL OF CHROMATOGRAPHY, 1993, 634 (02): : 309 - 315
  • [6] Peroxyoxalate chemiluminescence detection for capillary electrophoresis using membrane collection
    Shultz, LL
    Shippy, S
    Nieman, TA
    Sweedler, JV
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1998, 10 (04) : 329 - 337
  • [7] Simple and sensitive detection cell for capillary electrophoresis-chemiluminescence analysis using peroxyoxalate reagent
    Tsukagoshi, K
    Otsuka, M
    Hashimoto, M
    Nakajima, R
    Kimoto, H
    CHEMISTRY LETTERS, 2000, (02) : 98 - 99
  • [8] CAPILLARY ELECTROPHORESIS WITH A CHEMILUMINESCENCE DETECTOR USING THE TWO REACTIONS OF LUMINOL AND PEROXYOXALATE
    Tsuge, Kazumasa
    Tanaka, Takayuki
    Noda, Keiichi
    Tsukagoshi, Kazuhiko
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (08) : 1091 - 1101
  • [9] Flow-type chemiluminescence detection cell using an optical fiber for capillary electrophoresis
    Hashimoto, M
    Nakamura, T
    Tsukagoshi, K
    Nakajima, R
    Kondo, K
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1999, 72 (12) : 2673 - 2679
  • [10] Analysis of antioxidants using a capillary electrophoresis with chemiluminescence detection system
    Tsukagoshi, Kazuhiko
    Taniguchi, Takehito
    Nakajima, Riichiro
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 66 - 70