Chlamydia pneumoniae seropositivity predicts the risk of restenosis after percutaneous transluminal coronary angioplasty

被引:0
|
作者
Hayashida K. [1 ]
Tanaka M. [1 ]
Morita H. [1 ]
Hayashi F. [1 ]
Inada T. [1 ]
Suzuki H. [1 ]
Sakamoto T. [1 ]
Katsuragawa M. [1 ]
Hibino H. [1 ]
Kambara H. [1 ]
机构
[1] Cardiovascular Center, Osaka Red Cross Hospital, Osaka 543-8555, 5-53 Fudegasaki-cho, Tennouji-ku
关键词
Chlamydia pneumoniae; Coronary angioplasty; Ischemic heart disease; Restenosis;
D O I
10.1007/s003800200010
中图分类号
学科分类号
摘要
This study was done to evaluate whether anti-Chlamydia pneumoniae seropositivity can be a predictor of restenosis after coronary intervention. Recent studies indicate that latent infection with C. pneumoniae is associated with and could possibly cause atherosclerosis. However, it is unknown whether chronic infection with this micro-organism is involved in the mechanism of restenosis after percutaneous transluminal coronary angioplasty. We prospectively studied 78 consecutive patients (90 target lesions) with symptomatic coronary artery disease who underwent successful coronary intervention to a de novo lesion (conventional balloon angioplasty to 31 lesions and stent implantation to 59 lesions). At angioplasty, blood samples were collected to measure the serum level of anti-C. pneumoniae IgG to examine whether seropositive patients were prone to restenosis and whether the seropositivity could predict the risk of restenosis determined by follow-up coronary angiography performed within 6 months after the angioplasty. Restenosis, defined as more than 50% stenosis with an increase of 15% or more in the degree of stenosis from that measured on cineangiograms after angioplasty, developed in 36 of 62 seropositive patients and in 4 of 16 seronegative patients (58% vs 25%, P = 0.025). Lesions in the seropositive patients had a greater mean loss index (mean ± SD 0.75 ± 0.45 vs 0.35 ± 0.41, P < 0.001), which was defined as late loss (luminal diameter reduction at follow-up angiography) divided by acute gain (luminal diameter gain by angioplasty), in late loss (1.07 ± 0.64 mm vs 0.65 ± 0.79 mm, P = 0.019), in percentage of diameter stenosis (57% ± 20% vs 41% ± 21%, P = 0.003) and a lesser mean in minimal luminal diameter (1.18 ± 0.58 mm vs 1.67 ± 0.63 mm, P = 0.002) at follow-up angiography. In a multivariate logistic regression model, anti-C. pneumoniae IgG seropositivity was a strong independent predictor of restenosis compared to the other risk factors (odds ratio = 6.2, P = 0.01). C. pneumoniae could play an important role in the mechanism of restenosis and evaluation of the IgG seropositivity and may help to identify patients at high risk for restenosis.
引用
收藏
页码:137 / 145
页数:8
相关论文
共 50 条
  • [1] Chlamydia pneumoniae seropositivity predicts the risk of restenosis after percutaneous transluminal coronary angioplasty
    Hayashida, K
    Tanaka, M
    Morita, H
    Hayashi, F
    Inada, T
    Suzuki, H
    Sakamoto, T
    Katsuragawa, M
    Hibino, H
    Kambara, H
    [J]. HEART AND VESSELS, 2002, 16 (04) : 137 - 145
  • [2] Previous cytomegalovirus or Chlamydia pneumoniae infection and risk of restenosis after percutaneous transluminal coronary angioplasty
    Carlsson, J
    Miketic, S
    Mueller, KH
    Brom, J
    Ross, R
    vonEssen, R
    Tebbe, U
    [J]. LANCET, 1997, 350 (9086): : 1225 - 1225
  • [3] Elevated Chlamydia pneumoniae antibody and the risk of restenosis after percutaneous transluminal coronary angioplasty: Effect of clarithromycin in the prevention of restenosis
    Kumabashiri, I
    Horita, Y
    Uchiyama, K
    Hayashi, T
    Sakata, K
    Kazuyama, Y
    [J]. CIRCULATION, 1999, 100 (18) : 450 - 450
  • [4] Prior Cytomegalovirus, Chlamydia pneumoniae or Helicobacter pylori infection and the risk of restenosis after percutaneous transluminal coronary angioplasty
    Carlsson, J
    Miketic, S
    Brom, J
    Ross, R
    Bachmann, H
    Tebbe, U
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2000, 73 (02) : 165 - 171
  • [5] Hostility predicts restenosis after percutaneous transluminal coronary angioplasty
    Goodman, M
    Quigley, J
    Moran, G
    Meilman, H
    Sherman, M
    [J]. MAYO CLINIC PROCEEDINGS, 1996, 71 (08) : 729 - 734
  • [6] RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    PEDERSEN, HK
    VATNE, K
    SIMONSEN, S
    [J]. ACTA RADIOLOGICA, 1992, 33 (02) : 149 - 151
  • [7] RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    FOLEY, DP
    HERMANS, WM
    RENSING, BJ
    DEFEYTER, PJ
    SERRUYS, PW
    [J]. HERZ, 1992, 17 (01) : 1 - 17
  • [8] LIPOPROTEIN(A) IS NOT A RISK FACTOR FOR RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    SCHUMACHER, M
    TIRAN, A
    EBER, B
    TOPLAK, H
    WILDERSTRUSCHNIG, M
    KLEIN, W
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (05): : 572 - 572
  • [9] RESTENOSIS AFTER SUCCESSFUL PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY
    KLEIN, LW
    ROSENBLUM, J
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1990, 32 (05) : 365 - 382
  • [10] Cytomegalovirus and restenosis after percutaneous transluminal coronary angioplasty
    Moreno, PR
    Palacios, IF
    [J]. CIRCULATION, 2000, 101 (14) : E163 - E163