Analysis of Near-infrared Raman Spectroscopy as a New Technique for a Transcutaneous Non-invasive Diagnosis of Blood Components

被引:0
|
作者
S. Pilotto
M.T.T. Pacheco
L. Silveira Jr
A. Balbin Villaverde
R.A. Zângaro
机构
[1] IP&D,
[2] Universidade do Vale do Paraíba,undefined
[3] São José dos Campos,undefined
[4] SP,undefined
[5] Brazil,undefined
来源
Lasers in Medical Science | 2001年 / 16卷
关键词
Keywords: Blood components; Lactic acid; Near-infrared Raman spectroscopy; Transcutaneous diagnosis;
D O I
暂无
中图分类号
学科分类号
摘要
. Near-infrared Raman spectroscopy can be a new technique for physical evaluations, allowing the measurement of lactic acid concentrations, in blood or muscles, during the physical activity in a transcutaneous non-invasive way. Lactic acid accumulation in the human body is one of the factors that leads to fatigue and therefore it should be continually monitored during physical training. Our proposal is to use Raman spectroscopy to monitor the lactic acid present in an athlete without interrupting his exercise for sample collection. The experimental set-up for Raman spectroscopy comprised a near infrared laser at 830 nm, a Kaiser f/1.8 spectrometer and a liquid nitrogen cooled CCD detector. The radiation from the exciting laser is blocked in the collecting system by Kaiser holographic filters. A personal computer controls the entire system, saving and processing the Raman spectra. Experiments were undertaken to verify the presence of lactic acid in the Raman spectra of solutions of lactic acid in human serum and in blood from a Wistar rat. After these two experiments, another was developed in vivo in a Wistar rat, injecting intraperitoneally 1 ml of a 0.12 mol/l lactic acid aqueous solution. An optical fibre catheter touching the skin of the rat groin, over the ileac vein collected the Raman signal. The presence of lactic acid was detected inside a live organism, in a transcutaneous non-invasive way. The minimum lactic acid concentration that the equipment can detect was also studied. An experiment was undertaken for that purpose, in which the laser illuminated directly a quartz cuvette containing solutions with decreasing lactic acid concentrations up to values near to the physiological level in the human body. The results indicated that the technique can be suitable for the physical evaluation of athletes.
引用
收藏
页码:2 / 9
页数:7
相关论文
共 50 条
  • [1] Analysis of near-infrared Raman spectroscopy as a new technique for a transcutaneous non-invasive diagnosis of blood components
    Pilotto, S
    Pacheco, MTT
    Silveira, L
    Villaverde, AB
    Zângaro, RA
    LASERS IN MEDICAL SCIENCE, 2001, 16 (01) : 2 - 9
  • [2] Near-Infrared Spectroscopy (NIRS) for Non-Invasive Diagnosis
    Baig, Saeeda
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (11): : 1215 - 1216
  • [3] NEAR-INFRARED SPECTROSCOPY - A NEW TECHNIQUE FOR THE NON-INVASIVE MONITORING OF TISSUE AND BLOOD OXYGENATION INVIVO
    THORNILEY, MS
    WICKRAMASINGHE, YABD
    ROLFE, P
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1988, 16 (06) : 978 - 979
  • [4] Functional near-infrared spectroscopy in non-invasive neuromodulation
    Congcong Huo
    Gongcheng Xu
    Hui Xie
    Tiandi Chen
    Guangjian Shao
    Jue Wang
    Wenhao Li
    Daifa Wang
    Zengyong Li
    Neural Regeneration Research, 2024, 19 (07) : 1517 - 1522
  • [5] Functional near-infrared spectroscopy in non-invasive neuromodulation
    Huo, Congcong
    Xu, Gongcheng
    Xie, Hui
    Chen, Tiandi
    Shao, Guangjian
    Wang, Jue
    Li, Wenhao
    Wang, Daifa
    Li, Zengyong
    NEURAL REGENERATION RESEARCH, 2024, 19 (07) : 1517 - 1522
  • [6] Non-invasive Blood Glucose Measurement Scheme Based on Near-infrared Spectroscopy
    Wang Shulei
    Yuan Xueguang
    Zhang Yangan
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [7] Non-invasive technique to assess hepatic tissue oxygenation using near-infrared spectroscopy
    El-Desoky, A
    Seifalian, AM
    Davidson, BR
    BRITISH JOURNAL OF SURGERY, 1998, 85 (05) : 701 - 701
  • [9] Multicomponent blood analysis by near-infrared Raman spectroscopy
    Berger, AJ
    Koo, TW
    Itzkan, I
    Horowitz, G
    Feld, MS
    APPLIED OPTICS, 1999, 38 (13) : 2916 - 2926
  • [10] Multicomponent blood analysis by near-infrared Raman spectroscopy
    Berger, Andrew J.
    Koo, Tae-Woong
    Itzkan, Irving
    Horowitz, Gary
    Feld, Michael S.
    Applied Optics, 1999, 38 (13): : 2916 - 2926