Maximum cooling and maximum efficiency of thermoacoustic refrigerators

被引:0
|
作者
L. K. Tartibu
机构
[1] University of Johannesburg,Department of Mechanical Engineering Technology
[2] Doornfontein Campus,undefined
来源
Heat and Mass Transfer | 2016年 / 52卷
关键词
Acoustic Power; Cooling Load; Maximum Cool; Sound Level Meter; Maximum Coefficient;
D O I
暂无
中图分类号
学科分类号
摘要
This work provides valid experimental evidence on the difference between design for maximum cooling and maximum efficiency for thermoacoustic refrigerators. In addition, the influence of the geometry of the honeycomb ceramic stack on the performance of thermoacoustic refrigerators is presented as it affects the cooling power. Sixteen cordierite honeycomb ceramic stacks with square cross sections having four different lengths of 26, 48, 70 and 100 mm are considered. Measurements are taken at six different locations of the stack hot ends from the pressure antinode, namely 100, 200, 300, 400, 500 and 600 mm respectively. Measurement of temperature difference across the stack ends at steady state for different stack geometries are used to compute the cooling load and the coefficient of performance. The results obtained with atmospheric air showed that there is a distinct optimum depending on the design goal.
引用
收藏
页码:95 / 102
页数:7
相关论文
共 50 条
  • [1] Maximum cooling and maximum efficiency of thermoacoustic refrigerators
    Tartibu, L. K.
    HEAT AND MASS TRANSFER, 2016, 52 (01) : 95 - 102
  • [2] Maximum efficiency of absorption refrigerators at arbitrary cooling power
    Ye, Zhuolin
    Holubec, Viktor
    PHYSICAL REVIEW E, 2021, 103 (05)
  • [3] Maximum efficiency of low-dissipation refrigerators at arbitrary cooling power
    Holubec, Viktor
    Ye, Zhuolin
    PHYSICAL REVIEW E, 2020, 101 (05)
  • [4] MAXIMUM PRACTICAL EFFICIENCY OF HELIUM TEMPERATURE REFRIGERATORS
    VOTH, RO
    CRYOGENICS, 1981, 21 (11) : 635 - 640
  • [5] On the efficiency at maximum cooling power
    Apertet, Y.
    Ouerdane, H.
    Michot, A.
    Goupil, C.
    Lecoeur, Ph.
    EPL, 2013, 103 (04)
  • [6] IMPROVING EFFICIENCY OF THERMOACOUSTIC REFRIGERATORS BY A SECONDARY SOURCE
    Kleiven, Stig
    Kropp, Wolfgang
    Larsson, Krister
    PROCEEDINGS OF THE 17TH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, 2010,
  • [7] PERFORMANCE OF THERMOACOUSTIC REFRIGERATORS: COOLING LOAD AND COEFFICIENT OF PERFORMANCE
    Herman, Cila
    Lavin, Christopher
    Travnicek, Zdenek
    HT2008: PROCEEDING OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, VOL 3, 2009, : 755 - 760
  • [8] The performance of finite-time refrigerators at the maximum cooling load with a specified power input
    Guo, Jian
    Huang, Wenbo
    Jiang, Fangming
    EPL, 2019, 127 (06)
  • [9] THERMOACOUSTIC REFRIGERATORS
    GARRETT, SL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1992, 91 (01): : 517 - 518
  • [10] Maximum attainable performance of pulse tube refrigerators
    de Boer, PCT
    CRYOGENICS, 2002, 42 (02) : 123 - 125