Predictive value of technetium-99m sestamibi in patients with multiple myeloma and potential role in the follow-up

被引:0
|
作者
Leonardo Pace
Lucio Catalano
Silvana Del Vecchio
Francesca Di Gennaro
Amalia De Renzo
Giulia Sica
Catello Califano
Nicolina Tedesco
Giovanni Borrelli
Bruno Rotoli
Marco Salvatore
机构
[1] Cattedra di Medicina Nucleare,
[2] Dipartimento di Scienze Biomorfologiche e Funzionali,undefined
[3] Facoltà di Medicina e Chirurgia,undefined
[4] Università Federico II,undefined
[5] via Pansini 5,undefined
[6] 80131 Napoli,undefined
[7] Italy,undefined
[8] Centro C.N.R. per la Medicina Nucleare,undefined
[9] Napoli,undefined
[10] Italy,undefined
[11] Cattedra di Ematologia,undefined
[12] Dipartimento di Medicina Clinica e Sperimentale,undefined
[13] Facoltà di Medicina e Chirurgia,undefined
[14] Università Federico II,undefined
[15] Napoli,undefined
[16] Italy,undefined
来源
关键词
99mTc-MIBI scintigraphy Multiple myeloma Follow-up;
D O I
暂无
中图分类号
学科分类号
摘要
Technetium-99m 2-methoxyisobutylisonitrile (99mTc-MIBI or setamibi) has recently been proposed for use in the evaluation of multiple myeloma (MM). The aims of this study were to investigate its potential predictive value in patients with MM and its possible role in the follow-up. Thirty patients with MM who had undergone two 99mTc-MIBI scintigraphic studies at least 2 months apart constituted the study group; 22 of them received chemotherapy in the interval between the two scans. The scans were classified as showing pattern N when only physiological uptake was present, pattern D when diffuse bone marrow uptake was observed, pattern F when areas of focal uptake of the tracer were evident, and pattern F+D when both D and F patterns were observed. Comparative 99mTc-MIBI scintigraphy was considered indicative of disease progression when there was a worsening of the pattern (i.e. from N to D, or from N or D to F or to F+D) or an increase in the pattern D semiquantitative score. It was considered indicative of disease improvement when the opposite trend was observed; otherwise, it was considered to document a stable condition. A significant association was observed between the baseline scintigraphic pattern and clinical status at follow-up in the group of patients evaluated after chemotherapy (χ2=16.7, P<0.05). A negative baseline 99mTc-MIBI scintigram showed a high predictive accuracy (100%) for remission, while the presence of pattern F or F+D was often associated with a less favourable outcome. A multivariate analysis showed that 99mTc-MIBI uptake pattern has an added value in relation to known prognostic variables such as C-reactive protein. 99mTc-MIBI scintigraphy patterns at follow-up were significantly associated with the clinical status evaluated after chemotherapy (χ2=32.6, P<0.0001). Considering pattern N as indicating remission, pattern D stable condition, and pattern F or F+D progressive disease, a high concordance between scintigraphic findings and clinical status was found in the 22 patients undergoing chemotherapy (91%). Variation in 99mTc-MIBI findings comparing baseline and follow-up evaluations was significantly associated with clinical status both in patients undergoing chemotherapy (χ2=26.5, P<0.0005) and in those not undergoing chemotherapy (χ2=8.0, P<0.005). In conclusion, the results of this study suggest a prognostic value of 99mTc-MIBI scintigraphy in patients with MM and a potential role during the follow-up.
引用
收藏
页码:304 / 312
页数:8
相关论文
共 50 条
  • [1] Predictive value of technetium-99m sestamibi in patients with multiple myeloma and potential role in the follow-up
    Pace, L
    Catalano, L
    Del Vecchio, S
    Di Gennaro, F
    De Renzo, A
    Sica, G
    Califano, C
    Tedesco, N
    Borrelli, G
    Rotoli, B
    Salvatore, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (03) : 304 - 312
  • [2] Technetium-99m sestamibi scintigraphy in monitoring patients with multiple myeloma
    Pinto, AM
    Califano, C
    Di Gennaro, F
    De Renzo, A
    Catalano, L
    Pace, L
    HAEMATOLOGICA, 2000, 85 (09) : 1000 - 1001
  • [3] Technetium-99m sestamibi scintigraphy is sensitive and specific for the staging and the follow-up of patients with multiple myeloma: a multicentre study on 397 scans
    Mele, Anna
    Offidani, Massimo
    Visani, Giuseppe
    Marconi, Monica
    Cambioli, Filippo
    Nonni, Marco
    Catarini, Massimo
    Brianzoni, Ernesto
    Berbellini, Alfonso
    Ascoli, Giorgio
    Brunori, Marino
    Agostini, Vanessa
    Corvatta, Laura
    Isidori, Alessandro
    Spinelli, Aureliano
    Gradari, Marinella
    Leoni, Pietro
    BRITISH JOURNAL OF HAEMATOLOGY, 2007, 136 (05) : 729 - 735
  • [4] Different patterns of technetium-99m sestamibi uptake in multiple myeloma
    Leonardo Pace
    Lucio Catalano
    AnnaMaria Pinto
    Amalia De Renzo
    Francesca Di Gennaro
    Catello Califano
    Silvana Del Vecchio
    Bruno Rotoli
    Marco Salvatore
    European Journal of Nuclear Medicine, 1998, 25 : 714 - 720
  • [5] Different patterns of technetium-99m sestamibi uptake in multiple myeloma
    Pace, L
    Catalano, L
    Pinto, A
    De Renzo, A
    Di Gennaro, F
    Califano, C
    Del Vecchio, S
    Rotoli, B
    Salvatore, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (07) : 714 - 720
  • [6] Technetium-99m sestamibi scanning in multiple myeloma stem cell transplantation
    Look, RM
    Lim, SW
    Waxman, AD
    Gupta, PK
    Fuerst, MMP
    Kusuanco, DA
    Lawrence, GN
    Giles, FJ
    LEUKEMIA & LYMPHOMA, 1996, 20 (5-6) : 453 - 456
  • [7] Technetium 99m sestamibi in multiple myeloma
    Pace, L
    Del Vecchio, S
    Salvatore, M
    RADIOLOGY, 2005, 234 (01) : 312 - 313
  • [8] Technetium-99m sestamibi brain SPECT in the follow up of glioma for the response to chemotherapy
    Prigent, F
    Dubois, F
    Blond, S
    Steinling, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1213 - 1213
  • [9] Technetium-99m sestamibi brain SPECT in the follow-up of glioma for evaluation of response to chemotherapy: first results
    Florence Prigent-Le Jeune
    François Dubois
    Sarah Perez
    Serge Blond
    Marc Steinling
    European Journal of Nuclear Medicine and Molecular Imaging, 2004, 31 : 714 - 719
  • [10] Technetium-99m-sestaMIBI scintigraphy in multiple myeloma and related gammopathies:: a useful tool for the identification and follow-up of myeloma bone disease
    Balleari, E
    Villa, G
    Garrè, S
    Ghirlanda, P
    Agnese, G
    Carletto, M
    Clavio, M
    Ferrando, F
    Gobbi, M
    Mariani, G
    Ghio, R
    HAEMATOLOGICA, 2001, 86 (01) : 78 - 84