Modified precordial lead ECG SafOne on electrocardiography recordings

被引:0
|
作者
Wan Nishfa Dewi
Safri Safri
Iswadi Hasyim Rosma
机构
[1] Department of Medical Surgical Nursing,
[2] Faculty of Nursing,undefined
[3] Universitas Riau,undefined
[4] Department of Electronic Engineering,undefined
[5] Faculty of Engineering,undefined
[6] Universitas Riau,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Adaptability in precordial lead placement is one of the sources of electrocardiography inaccuracy. The present experimental study aimed to investigate the modified precordial lead ECG SafOne on electrocardiography recordings. Fourteen subjects were selected using purposive sampling. All the artefacts that emerged in the ECG recording results from the subjects using both the modified precordial lead ECG SafOne and precordial lead standard ECG were measured and identified. Data were analysed using a t test to examine the difference in the artefacts from all ECG recordings. The electrocardiography recordings of males aged 21–25 years using modified precordial lead ECG SafOne showed that out of 168 precordial leads from 14 subjects, two indicated artefact images in lead II (1.19%) and three in lead III (1.79%). The statistical test showed no significant difference in terms of artefacts that emerged in the electrocardiography recording results from both standard ECG and modified precordial lead ECG SafOne (p = 0.096). The modified precordial lead ECG SafOne showed no significant effect on ECG recordings related to artefacts. Additionally, the precordial lead ECG SafOne had no substantial difference in the presence of artefacts compared to the standard ECG. Therefore, ECG SafOne was usable as an ECG precordial lead for electrocardiography recording.
引用
收藏
相关论文
共 50 条
  • [1] Modified precordial lead ECG SafOne on electrocardiography recordings
    Dewi, Wan Nishfa
    Safri, Safri
    Rosma, Iswadi Hasyim
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [2] PRECORDIAL ECG LEAD FOR CHEST OPERATIONS
    DALTON, B
    ANESTHESIA AND ANALGESIA, 1976, 55 (05): : 740 - 741
  • [3] The effect of precordial lead displacement on ECG morphology
    Michał Kania
    Hervé Rix
    Małgorzata Fereniec
    Heriberto Zavala-Fernandez
    Dariusz Janusek
    Tomasz Mroczka
    Günter Stix
    Roman Maniewski
    Medical & Biological Engineering & Computing, 2014, 52 : 109 - 119
  • [4] Accuracy in precordial electrocardiogram (ECG) lead placement
    Medani, S.
    Caples, N.
    Hensey, M.
    Hussaini, A.
    Owens, P.
    EUROPEAN HEART JOURNAL, 2015, 36 : 87 - 87
  • [5] The effect of precordial lead displacement on ECG morphology
    Kania, Michal
    Rix, Herve
    Fereniec, Malgorzata
    Zavala-Fernandez, Heriberto
    Janusek, Dariusz
    Mroczka, Tomasz
    Stix, Guenter
    Maniewski, Roman
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (02) : 109 - 119
  • [6] Feasibility and Reliability of Smartwatch to Obtain Precordial Lead Electrocardiogram Recordings
    Sprenger, Nora
    Shamloo, Alireza Sepehri
    Schaefer, Jonathan
    Burkhardt, Sarah
    Mouratis, Konstantinos
    Hindricks, Gerhard
    Bollmann, Andreas
    Arya, Arash
    SENSORS, 2022, 22 (03)
  • [7] Direction of Ventricle Contraction Based on Precordial Lead ECG Signal
    Goeirmanto, Leonard
    Mengko, Richard
    Rajab, Tati Latifah
    2016 4TH INTERNATIONAL CONFERENCE ON CYBER AND IT SERVICE MANAGEMENT, 2016, : 174 - 176
  • [8] CLINICALLY PRACTICAL LEAD SYSTEMS FOR IMPROVED ELECTROCARDIOGRAPHY - COMPARISON WITH PRECORDIAL GRIDS AND CONVENTIONAL LEAD SYSTEMS
    LUX, RL
    BURGESS, MJ
    WYATT, RF
    EVANS, AK
    VINCENT, GM
    ABILDSKOV, JA
    CIRCULATION, 1979, 59 (02) : 356 - 363
  • [9] A MODIFIED AXIAL LEAD SYSTEM FOR ORTHOGONAL LEAD ELECTROCARDIOGRAPHY
    MACFARLA.PW
    CARDIOVASCULAR RESEARCH, 1969, 3 (04) : 510 - &
  • [10] PRECORDIAL LEADS IN CLINICAL ELECTROCARDIOGRAPHY
    KATZ, LN
    DOLGIN, M
    LANGENDORF, R
    MEDICAL CLINICS OF NORTH AMERICA, 1948, (NCHIC) : 197 - 212