Compressed sensing reconstruction shortens the acquisition time for myocardial perfusion imaging: a simulation study

被引:0
|
作者
Mitsuha Fukami
Norikazu Matsutomo
Takeyuki Hashimoto
Tomoaki Yamamoto
Masayuki Sasaki
机构
[1] Kyorin University,Department of Medical Radiological Technology, Faculty of Health Sciences
[2] Kyushu University,Department of Medical Quantum Science, Graduate School of Medical Sciences
[3] Kyushu University,Department of Medical Quantum Science, Faculty of Medical Sciences
来源
Radiological Physics and Technology | 2023年 / 16卷
关键词
Compressed sensing; Myocardial perfusion image; Acquisition time reduction; Reconstruction methods; Total variation;
D O I
暂无
中图分类号
学科分类号
摘要
Compressed sensing (CS) has been used to improve image quality in single-photon emission tomography (SPECT) imaging. However, the effects of CS on image quality parameters in myocardial perfusion imaging (MPI) have not been investigated in detail. This preliminary study aimed to compare the performance of CS-iterative reconstruction (CS-IR) with filtered back-projection (FBP) and maximum likelihood expectation maximization (ML-EM) on their ability to reduce the acquisition time of MPI. A digital phantom that mimicked the left ventricular myocardium was created. Projection images with 120 and 30 directions (360°), and with 60 and 15 directions (180°) were generated. The SPECT images were reconstructed using FBP, ML-EM, and CS-IR. The coefficient of variation (CV) for the uniformity of myocardial accumulation, septal wall thickness, and contrast ratio (Contrast) of the defect/normal lateral wall were calculated for evaluation. The simulation was performed ten times. The CV of CS-IR was lower than that of FBP and ML-EM in both 360° and 180° acquisitions. The septal wall thickness of CS-IR at the 360° acquisition was inferior to that of ML-EM, with a difference of 2.5 mm. Contrast did not differ between ML-EM and CS-IR for the 360° and 180° acquisitions. The CV for the quarter-acquisition time in CS-IR was lower than that for the full-acquisition time in the other reconstruction methods. CS-IR has the potential to reduce the acquisition time of MPI.
引用
收藏
页码:397 / 405
页数:8
相关论文
共 50 条
  • [1] Compressed sensing reconstruction shortens the acquisition time for myocardial perfusion imaging: a simulation study
    Fukami, Mitsuha
    Matsutomo, Norikazu
    Hashimoto, Takeyuki
    Yamamoto, Tomoaki
    Sasaki, Masayuki
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2023, 16 (03) : 397 - 405
  • [2] The application of compressed sensing reconstruction for myocardial perfusion image shortens the acquisition time: a simulation study
    Fukami, Mitsuha
    Matsutomo, Norikazu
    Takeyuki, Hashimoto
    Yamamoto, Tomoaki
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63
  • [3] Shorter acquisition time of myocardial perfusion SPECT study using a novel reconstruction method
    Braun, Shimon S.
    Chausovsky, G.
    Yuzefovich, B.
    Sachs, J.
    Keren, G.
    Even-Sapir, E.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S57 - S57
  • [4] Reducing acquisition time in clinical MRI by data undersampling and compressed sensing reconstruction
    Hollingsworth, Kieren Grant
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (21): : R297 - R322
  • [5] Acquisition and Reconstruction of Undersampled Radial Data for Myocardial Perfusion Magnetic Resonance Imaging
    Adluru, Ganesh
    McGann, Chris
    Speier, Peter
    Kholmovski, Eugene G.
    Shaaban, Akrarn
    DiBella, Edward V. R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 466 - 473
  • [6] Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging
    Lotte H. Enevoldsen
    Changez A. K. Menashi
    Ulrik B. Andersen
    Lars T. Jensen
    Otto M. Henriksen
    Journal of Nuclear Cardiology, 2013, 20 : 1086 - 1092
  • [7] Online MR image reconstruction for compressed sensing acquisition in T2*imaging
    El Gueddari, Loubna
    Chouzenoux, Emilie
    Vignaud, Alexandre
    Pesquet, Jean-Christophe
    Ciuciu, Philippe
    WAVELETS AND SPARSITY XVIII, 2019, 11138
  • [8] Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging
    Enevoldsen, Lotte H.
    Menashi, Changez A. K.
    Andersen, Ulrik B.
    Jensen, Lars T.
    Henriksen, Otto M.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (06) : 1086 - 1092
  • [9] How reliable is a half time acquisition for gated myocardial perfusion imaging?
    James, G.
    Jennings, A.
    O'Brien, J.
    Cullis, J.
    Notghi, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S540 - S540
  • [10] New reconstruction algorithm allows shortened acquisition time for myocardial perfusion SPECT
    Ines Valenta
    Valerie Treyer
    Lars Husmann
    Oliver Gaemperli
    Michael J. Schindler
    Bernhard A. Herzog
    Patrick Veit-Heibach
    Ronny R. Buechel
    René Nkoulou
    Aju P. Pazhenkottil
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 750 - 757