Fiberoptic biosensors based on chemiluminescent reactions

被引:0
|
作者
Christophe A. Marquette
Agnès Degiuli
Loïc J. Blum
机构
[1] Université Lyon 1,Laboratoire de Génie Enzymatique
[2] 43 bd du 11 novembre 1918,undefined
来源
Applied Biochemistry and Biotechnology | 2000年 / 89卷
关键词
Biosensors; chemiluminescence; chlorophenols; electrochemiluminescence; fiberoptic sensor; flow injection analysis; glucose; lactate; luminol; peroxidase;
D O I
暂无
中图分类号
学科分类号
摘要
The chemiluminescence of luminol in the presence of H2O2 has been exploited to develop fiberoptic biosensors associated with flow injection analysis systems. A chlorophenol sensor was developed based on the ability of certain halophenols to enhance the peroxidase-catalyzed luminol chemiluminescence. Horseradish peroxidase immobilized on a collagen membrane was used. Ten chlorophenols have been tested with this chemiluminescent-based sensor. The lower detection limit was obtained with 4-chloro-3-methylphenol and was equal to 0.01 µM. Electrochemiluminescent-based fiberoptic biosensors for glucose and lactate were also developed using glucose oxidase or lactate oxidase immobilized on polyamide membranes. In the presence of oxidase-generated H2O2, the light emission was triggered electrochemically by means of a glassy carbon electrode polarized at +425 mV vs a platinum pseudo-reference electrode. The detection limits for glucose and lactate were 150 and 60 pmol, respectively, and the dynamic ranges were linear from 150 pmol to 600 nmol and from 60 pmol to 60 nmol, respectively.
引用
收藏
页码:107 / 115
页数:8
相关论文
共 50 条
  • [1] Fiberoptic biosensors based on chemiluminescent reactions
    Marquette, CA
    Degiuli, A
    Blum, LJ
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) : 107 - 115
  • [2] FIBEROPTIC BIOSENSORS
    ARNOLD, MA
    JOURNAL OF BIOTECHNOLOGY, 1990, 15 (03) : 219 - 228
  • [3] Chemiluminescent biosensors based on porous supports with immobilized peroxidase
    Rubtsova, MY
    Kovba, GV
    Egorov, AM
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (01): : 75 - 85
  • [4] Chemiluminescent biosensors based on porous supports with immobilized peroxidase
    Rubtsova, Maya Yu.
    Kovba, Galina V.
    Egorov, Alexey M.
    Biosensors and Bioelectronics, 1998, 13 (01): : 75 - 85
  • [5] DETERMINATION OF SULFITE BY USE OF A FIBEROPTIC BIOSENSOR BASED ON A CHEMILUMINESCENT REACTION
    HLAVAY, J
    GUILBAULT, GG
    ANALYTICA CHIMICA ACTA, 1994, 299 (01) : 91 - 96
  • [6] REMOTE FIBEROPTIC BIOSENSORS BASED ON EVANESCENT FIELD FLUOROIMMUNOASSAY
    ANDRADE, J
    LIN, JN
    HERRON, J
    REICHERT, M
    HLADY, V
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 10 - MBTD
  • [7] Chemiluminescent Biosensors with Immobilized Peroxidase
    Laboratory of Enzyme Engineering, Chemistry Faculty, M.V. Lomonosov Moscow State Univ., Moscow, 119899, Russia
    Lumin., 1 (33-36):
  • [8] Chemiluminescent biosensors with immobilized peroxidase
    Kovba, GV
    Rubtsova, MY
    Egorov, AM
    JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1997, 12 (01): : 33 - 36
  • [9] FIBEROPTIC BIOSENSORS BASED ON TOTAL INTERNAL-REFLECTION FLUORESCENCE
    ROGERS, KR
    ANIS, NA
    VALDES, JJ
    ELDEFRAWI, ME
    ACS SYMPOSIUM SERIES, 1992, 511 : 165 - 173
  • [10] Chemiluminescent Emitter Based on the Reactions by Ce(IV)
    Fujimori, Keiichi
    Tanimoto, Akihisa
    Takada, Kazunari
    Misaki, Yoshitomo
    Kimura, Shinichi
    Moriuchi-Kawakami, Takayo
    Shibutani, Yasuhiko
    ANALYTICAL LETTERS, 2008, 41 (16) : 2954 - 2962