A new technique for measuring the flow velocity of nano-scale powders is used. The hot-wire anemometry method widely used in gas flows is employed for investigating nanopowder flows. By way of illustration, the flows of nanopowders of aluminum oxide C and silicon dioxide aerosil A-90 and A-380 in a vertical channel are studied. The results obtained show that nanoscale powder flow investigation by means of the hot-wire anemometry is promising.
引用
收藏
页码:281 / 287
页数:6
相关论文
共 50 条
  • [1] Use of hot-wire anemometry for measuring the nanopowder flow velocity
    Bardakhanov, S. P.
    Lysenko, V. I.
    Trufanov, D. Yu.
    FLUID DYNAMICS, 2012, 47 (02) : 281 - 287
  • [2] Hot-Wire Anemometry for Velocity Measurements in Nanopowder Flows
    Bardakhanov, Sergey P.
    Joo, Sang W.
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (03): : 0345011 - 0345014
  • [3] HOT-WIRE ANEMOMETRY IN TRANSONIC FLOW
    HORSTMAN, CC
    ROSE, WC
    AIAA JOURNAL, 1977, 15 (03) : 395 - 401
  • [4] VELOCITY CALIBRATION RELATIONSHIPS FOR HOT-WIRE ANEMOMETRY
    BRUUN, HH
    KHAN, MA
    ALKAYIEM, HH
    FARDAD, AA
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1988, 21 (02): : 225 - 232
  • [5] DIRECT MEASUREMENT OF VELOCITY BY HOT-WIRE ANEMOMETRY
    BAUER, AB
    AIAA JOURNAL, 1965, 3 (06) : 1189 - &
  • [6] USE OF THE HOT-WIRE ANEMOMETRY FOR VELOCITY AND TEMPERATURE-MEASUREMENTS IN A TURBOMACHINE
    BLIDI, S
    MITON, H
    JOURNAL DE PHYSIQUE III, 1995, 5 (10): : 1513 - 1535
  • [7] HOT-WIRE ANEMOMETRY
    COMTEBELLOT, G
    ANNUAL REVIEW OF FLUID MECHANICS, 1976, 8 : 209 - 231
  • [8] HOT-WIRE ANEMOMETRY IN MODERATELY HEATED FLOW
    FIRASATALI, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (02): : 185 - 191
  • [9] USE OF HOT-WIRE ANEMOMETRY TO MEASURE VELOCITY OF THE LIMB DURING HUMAN MOVEMENT
    SUN, SC
    MOTE, CD
    SKINNER, HB
    JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (05): : 435 - 439
  • [10] HOT-WIRE ANEMOMETRY IN RAREFIED-GAS FLOW
    GOTTESDIENER, L
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1980, 13 (09): : 908 - 913