Evaluation of the anterior acetabular coverage with a false profile radiograph considering appropriate range of positioning

被引:0
|
作者
Yasuhiko Kokubu
Shinya Kawahara
Kenji Kitamura
Satoshi Hamai
Goro Motomura
Satoshi Ikemura
Taishi Sato
Ryosuke Yamaguchi
Daisuke Hara
Masanori Fujii
Yasuharu Nakashima
机构
[1] Kyushu University,Department of Orthopaedic Surgery, Graduate School of Medical Sciences
[2] Kyushu University,Department of Medical
[3] Saga University,Engineering Collaboration for Healthy Longevity
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This study aimed to (1) set a reference value for anterior center edge angle (ACEA) for preoperative planning of periacetabular osteotomy (PAO), (2) investigate the effects of pelvic rotation and inclination from false profile (FP) radiographs on the measured ACEA, and (3) determine the “appropriate range of positioning” for FP radiograph. This single-centered, retrospective study analyzed 61 patients (61 hips) who underwent PAO from April 2018 and May 2021. ACEA was measured in each digitally reconstructed radiography (DRR) image of the FP radiograph reconstructed in different degrees of pelvic rotation. Detailed simulations were performed to determine the “appropriate range of positioning” (0.67 < ratio of the distance between the femoral heads to the diameter of the femoral head < 1.0). The vertical-center-anterior (VCA) angle was measured on the CT sagittal plane considering the patient-specific standing positions, and its correlation with the ACEA was investigated. The reference value of ACEA was determined by receiver operating characteristic (ROC) curve analysis. The ACEA measurement increased by 0.35° for every 1° pelvic rotation approaching the true lateral view. The pelvic rotation with the “appropriate range of positioning” was found at 5.0° (63.3–68.3°). The ACEA on the FP radiographs showed a good correlation with the VCA angle. The ROC curve revealed that an ACEA < 13.6° was associated with inadequate anterior coverage (VCA < 32°). Our findings suggest that during preoperative PAO planning, an ACEA < 13.6° on FP radiographs indicates insufficient anterior acetabular coverage. Images with the “appropriate positioning” can also have a measurement error of 1.7° due to the pelvic rotation.
引用
收藏
相关论文
共 19 条
  • [1] Evaluation of the anterior acetabular coverage with a false profile radiograph considering appropriate range of positioning
    Kokubu, Yasuhiko
    Kawahara, Shinya
    Kitamura, Kenji
    Hamai, Satoshi
    Motomura, Goro
    Ikemura, Satoshi
    Sato, Taishi
    Yamaguchi, Ryosuke
    Hara, Daisuke
    Fujii, Masanori
    Nakashima, Yasuharu
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] The Effect of Acetabular Rim Recession on Anterior Acetabular Coverage A Cadaveric Study Using the False-Profile Radiograph
    Kling, Scott
    Karns, Michael R.
    Gebhart, Jeremy
    Kosmas, Christos
    Robbin, Mark
    Nho, Shane J.
    Bedi, Asheesh
    Salata, Michael J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (04): : 957 - 964
  • [3] Influence of leg-length discrepancy on anterior acetabular coverage using false profile image
    Kudo, Masaki
    Sekimoto, Tomohisa
    Sakamoto, Takero
    Chosa, Etsuo
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (05) : 861 - 867
  • [4] Anterior acetabular head index of the hip on false-profile views - New index of anterior acetabular cover
    Chosa, E
    Tajima, N
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06): : 826 - 829
  • [5] CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data
    Needell, Steven D.
    Borzykowski, Ross M.
    Carreira, Dominic S.
    Kozy, John
    SKELETAL RADIOLOGY, 2014, 43 (11) : 1605 - 1611
  • [6] CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data
    Steven D. Needell
    Ross M. Borzykowski
    Dominic S. Carreira
    John Kozy
    Skeletal Radiology, 2014, 43 : 1605 - 1611
  • [7] Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne's false-profile radiograph and on computed tomography
    Cheng, Hui
    Zhang, Liqiang
    Luo, Dianzhong
    Ren, Ningtao
    Zhang, Zhendong
    Gu, Wang
    Hu, Yongcheng
    Zhang, Hong
    JOURNAL OF HIP PRESERVATION SURGERY, 2023, 10 (01): : 42 - 47
  • [8] Assessment of Acetabular Morphology Using the Acetabular Anterior Center-Edge Angle on Modified False-Profile Radiographs
    Murphy, Michael M.
    Atkins, Penny R.
    Kobayashi, Evangeline F.
    Anderson, Andrew E.
    Maak, Travis G.
    Nechyporenko, Anatoliy, V
    Aoki, Stephen K.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (11): : 3060 - 3066
  • [9] Evaluation of a method for the assessment of anterior acetabular coverage and hip joint space width
    Romuald Ferre
    Emmanuel Gibon
    Moussa Hamadouche
    Antoine Feydy
    Jean-Luc Drapé
    Skeletal Radiology, 2014, 43 : 599 - 605
  • [10] Evaluation of a method for the assessment of anterior acetabular coverage and hip joint space width
    Ferre, Romuald
    Gibon, Emmanuel
    Hamadouche, Moussa
    Feydy, Antoine
    Drape, Jean-Luc