A CCD area detector for X-ray diffraction under high pressure for rotating anode source

被引:0
|
作者
Amar Sinha
Alka B. Garg
V. Vijayakumar
B. K. Godwal
S. K. Sikka
机构
[1] Bhabha Atomic Research Centre,High Pressure Physics Division
来源
Bulletin of Materials Science | 2000年 / 23卷
关键词
CCD X-ray detector; X-ray diffraction; high pressure studies;
D O I
暂无
中图分类号
学科分类号
摘要
Details of a two-dimensional X-ray area detector developed using a charge coupled device, a image intensifier and a fibre optic taper are given. The detector system is especially optimized for angle dispersive X-ray diffraction set up using rotating anode generator as X-ray source. The performance of this detector was tested by successfully carrying out powder X-ray diffraction measurements on various materials such as intermetallics AuIn2, AuGa2, high Z material Pd and low Z scatterer adamantane (C10H16) at ambient conditions. Its utility for quick detection of phase transitions at high pressures with diamond anvil cell is demonstrated by reproducing the known pressure induced structural transitions in RbI, KI and a new structural phase transition in AuGa2 above 10 GPa. Various softwares have also been developed to analyze data from this detector.
引用
收藏
页码:151 / 154
页数:3
相关论文
共 50 条
  • [1] A CCD area detector for X-ray diffraction under high pressure for rotating anode source
    Sinha, A
    Garg, AB
    Vijayakumar, V
    Godwal, BK
    Sikka, SK
    BULLETIN OF MATERIALS SCIENCE, 2000, 23 (02) : 151 - 154
  • [2] Performance of a CCD detector using rotating anode generator for X-ray diffraction studies at ambient and high pressure conditions
    Garg, AB
    Sinha, A
    Vijayakumar, V
    Godwal, BK
    Sikka, SK
    SOLID STATE PHYSICS, VOL 41, 1998, 1999, : 227 - 228
  • [3] SOME HIGH-PRESSURE X-RAY-DIFFRACTION STUDIES USING BERYLLIUM GASKETING ON A DIFFRACTOMETER WITH ROTATING ANODE X-RAY SOURCE
    VOHRA, YK
    VIJAYAKUMAR, V
    GODWAL, BK
    SIKKA, SK
    CHIDAMBARAM, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (10): : 1593 - 1597
  • [4] Scanning CCD Detector for X-ray Powder Diffraction
    Madden, T.
    Baldwin, J.
    Von Dreele, R.
    Suchomel, M.
    Toby, B. H.
    17TH PAN-AMERICAN SYNCHROTRON RADIATION INSTRUMENTATION CONFERENCE SRI2013, 2014, 493
  • [5] SOME HIGH-PRESSURE X-RAY-DIFFRACTION STUDIES USING BERYLLIUM GASKETING TECHNIQUE ON A DIFFRACTOMETER WITH ROTATING ANODE X-RAY SOURCE
    VOHRA, YK
    KUMAR, VV
    GODWAL, BK
    SIKKA, SK
    CHIDAMBARAM, R
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C141 - C141
  • [6] High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector
    Imai, Yasuhiko
    Kimura, Shigeru
    Sakata, Osami
    Sakaia, Akira
    X-RAY OPTICS AND MICROANALYSIS, PROCEEDINGS, 2010, 1221 : 30 - +
  • [7] Combined X-ray absorption and X-ray diffraction under high pressure
    Itie, Jean-Paul
    Polian, Alain
    Baudelet, Francois
    Mocuta, Cristian
    Thiaudiere, Dominique
    Fonda, Emiliano
    Irifune, Tetsuo
    HIGH PRESSURE RESEARCH, 2016, 36 (03) : 479 - 492
  • [8] Siemens smart CCD detector applied to protein crystallography with synchrotron and rotating anode x-ray sources
    Hovestreydt, E.
    Phillips, J.
    Chambers, J.
    Fait, J.
    Schuster, M.
    Sparks, R.
    Journal De Physique. IV : JP, 1996, 6 (04): : 4 - 23
  • [9] Siemens smart CCD detector applied to protein crystallography with synchrotron and rotating anode X-ray sources
    Hovestreydt, E
    Phillips, J
    Chambers, J
    Fait, J
    Schuster, M
    Sparks, R
    JOURNAL DE PHYSIQUE IV, 1996, 6 (C4): : 23 - 32
  • [10] X-ray magnetic diffraction under high pressure
    Wang, Yishu
    Rosenbaum, T. F.
    Feng, Yejun
    IUCRJ, 2019, 6 : 507 - 520