Removal of Electrooculogram Artifacts from Electroencephalogram Using Canonical Correlation Analysis with Ensemble Empirical Mode Decomposition

被引:0
|
作者
Banghua Yang
Tao Zhang
Yunyuan Zhang
Wanquan Liu
Jianguo Wang
Kaiwen Duan
机构
[1] Shanghai University,Department of Automation, School of Mechatronic Engineering and Automation, Key Laboratory of Power Station Automation Technology
[2] Curtin University,Department of Computing
来源
Cognitive Computation | 2017年 / 9卷
关键词
Electroencephalogram (EEG); Electrooculogram (EOG); Artifacts removal; Canonical correlation analysis (CCA); Ensemble empirical mode decomposition (EEMD);
D O I
暂无
中图分类号
学科分类号
摘要
Electrooculogram (EOG) is one of the major artifacts in the design of electroencephalogram (EEG)-based brain computer interfaces (BCIs). That removing EOG artifacts automatically while retaining more neural data will benefit for further feature extraction and classification. In order to remove EOG artifacts automatically as well as reserve more useful information from raw EEG, this paper proposes a novel blind source separation method called CCA-EEMD (canonical correlation analysis, ensemble empirical mode decomposition). Technically, the major steps of CCA-EEMD are as follows: Firstly, the multiple-channel original EEG signals are separated into several uncorrelated components using CCA. Then, the EOG component can be identified automatically by its kurtosis value. Next, the identified EOG component is decomposed into several intrinsic mode functions (IMFs) by EEMD. The IMFs uncorrelated to the EOG component are recognized and retained, and a new component will be constructed by the retained IMFs. Finally, the clean EEG signals are reconstructed. Keep in mind that the novelty of this paper is that the identified EOG component is not removed directly but used to extract neural EEG data, which would keep more effective information. Our tests with the data of seven subjects demonstrate that the proposed method has distinct advantages over other two commonly used methods in terms of average root mean square error [37.71 ± 0.14 (CCA-EEMD), 44.72 ± 0.13 (CCA), 49.59 ± 0.16 (ICA)], signal-to-noise ratio [3.59 ± 0.24 (CCA-EEMD), −6.53 ± 0.18(CCA), −8.43 ± 0.26 (ICA)], and classification accuracy [0.88 ± 0.002 (CCA-EEMD), 0.79 ± 0.001 (CCA), 0.73 ± 0.002 (ICA)]. The proposed method can not only remove EOG artifacts automatically but also keep the integrity of EEG data to the maximum extent.
引用
收藏
页码:626 / 633
页数:7
相关论文
共 50 条
  • [1] Removal of Electrooculogram Artifacts from Electroencephalogram Using Canonical Correlation Analysis with Ensemble Empirical Mode Decomposition
    Yang, Banghua
    Zhang, Tao
    Zhang, Yunyuan
    Liu, Wanquan
    Wang, Jianguo
    Duan, Kaiwen
    [J]. COGNITIVE COMPUTATION, 2017, 9 (05) : 626 - 633
  • [2] A Novel Method Based on Combination of Independent Component Analysis and Ensemble Empirical Mode Decomposition for Removing Electrooculogram Artifacts From Multichannel Electroencephalogram Signals
    Teng, Chao-Lin
    Zhang, Yi-Yang
    Wang, Wei
    Luo, Yuan-Yuan
    Wang, Gang
    Xu, Jin
    [J]. FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [3] Removal of Muscle Artifacts from Single-Channel EEG Based on Ensemble Empirical Mode Decomposition and Multiset Canonical Correlation Analysis
    Chen, Xun
    He, Chen
    Peng, Hu
    [J]. JOURNAL OF APPLIED MATHEMATICS, 2014,
  • [4] The Use of Ensemble Empirical Mode Decomposition With Canonical Correlation Analysis as a Novel Artifact Removal Technique
    Sweeney, Kevin T.
    McLoone, Sean F.
    Ward, Tomas E.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (01) : 97 - 105
  • [5] An Electroencephalogram Artifacts Removal Algorithm for Electroencephalogram Signals Based on Sample Entropy-Complete Ensemble Empirical Mode Decomposition with Adaptive Noise
    Yang, Lei
    Yang, Fan
    He, Yan
    [J]. Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2020, 54 (08): : 177 - 184
  • [6] Research on automatic removal of ocular artifacts from single channel electroencephalogram signals based on wavelet transform and ensemble empirical mode decomposition
    Zhang, Rui
    Liu, Jiajun
    Chen, Mingming
    Zhang, Lipeng
    Hu, Yuxia
    [J]. Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2021, 38 (03): : 473 - 482
  • [7] Removal of Artifacts in ECG using Empirical Mode Decomposition
    Anapagamini, S. A.
    Rajavel, R.
    [J]. 2013 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND SIGNAL PROCESSING (ICCSP), 2013, : 288 - 292
  • [8] Removal of artifacts in knee joint vibroarthrographic signals using ensemble empirical mode decomposition and detrended fluctuation analysis
    Wu, Yunfeng
    Yang, Shanshan
    Zheng, Fang
    Cai, Suxian
    Lu, Meng
    Wu, Meihong
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (03) : 429 - 439
  • [9] ECG-Driven Extraction of Respiration Rate Using Ensemble Empirical Mode Decomposition and Canonical Correlation Analysis
    Kumar, Vineet
    Singh, Gurpreet
    [J]. PROCEEDINGS OF THE SECOND INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATION TECHNOLOGIES, IC3T 2015, VOL 3, 2016, 381 : 281 - 289
  • [10] Canonical correlation analysis applied to remove muscle artifacts from the electroencephalogram
    De Clercq, Wim
    Vergult, Anneleen
    Vanrumste, Bart
    Van Paesschen, Wim
    Van Huffel, Sabine
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (12) : 2583 - 2587