Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge

被引:0
|
作者
Timo Frett
Guido Petrat
Michael Arz
Carole Leguy
机构
[1] German Aerospace Center (DLR),Institute of Measuring and Sensor Technology
[2] Institute of Aerospace Medicine,undefined
[3] Ruhr West University of Applied Science,undefined
来源
关键词
Telerobotic; Artificial gravity; Ultrasound imaging; Vascular response; Space physiology;
D O I
暂无
中图分类号
学科分类号
摘要
Artificial Gravity generated by Short Arm Human Centrifuges is a promising multi-system countermeasure for physiological deconditioning during long duration space flights. To allow a continuous assessment of cardiovascular hemodynamics during centrifugation, a telerobotic robotic system holding an ultrasound probe has been installed on a Short Arm Human Centrifuge. A feasibility study was conducted to define the use capabilities and limitations of such a novel method. The objective of this study is to estimate the reproducibility and precision of remotely controlled vascular ultrasound assessment under centrifugation by assessing peripheral vascular diameter and wall distension. Four repeated centrifugation runs of 5 min, with 2.4 g at feet level, were performed including a 15 min rest between each run for a group of eight healthy male volunteers. Vascular diameter and distention were assessed for the common carotid artery (CCA) and the femoral artery (FA) by ultrasound imaging using a 10 MHz linear array probe (Mylab1, Esaote). Ultrasound measurements were consecutively performed: a) by an expert user in hand-held mode in standing as well as supine position, b) using the telerobotic arm without centrifugation as baseline and c) using the telerobotic arm during centrifugation. Vascular responses were compared between baseline and under centrifugation. Inter-, intra-registration and group variability have been assessed for hand-held and remotely controlled examination. The results show that intra-registration variability, σh , was always smaller than inter-registration variability, σm, that is in turned smaller than the inter-subject variability σg (σh < σm < σg). Centrifugation caused no significant changes in CCA diameter but a lower carotid distension compared to manual and robotic ultrasound in supine position (p < 0.05). Femoral diameter was significantly decreased in hypergravity compared to robotic sonography without centrifugation. A good reproducibility and precision of the remotely controlled vascular ultrasound assessment under centrifugation could be demonstrated. In conclusion, arterial wall dynamics can be precisely assessed for the CCA and femoral artery during centrifugation using a telerobotic ultrasound measurement system. Potential improvements to further enhance reproducibility and safety of the system are discussed.
引用
收藏
相关论文
共 50 条
  • [1] Quantitative Evaluation of a Telerobotic System for Vascular Ultrasound Measurement on a Short Arm Human Centrifuge
    Frett, Timo
    Petrat, Guido
    Arz, Michael
    Leguy, Carole
    MICROGRAVITY SCIENCE AND TECHNOLOGY, 2021, 33 (01)
  • [2] CONTINUOUS MONITORING OF HEMODYNAMICS IN THE SHORT ARM HUMAN CENTRIFUGE: A FEASIBILITY STUDY
    Londono, F.
    Uytterhaegen, B.
    Kassel, R.
    Vanraemdonck, R.
    Beck, A.
    Comet, B.
    Runge, A.
    Segers, P.
    JOURNAL OF HYPERTENSION, 2015, 33 : E104 - E104
  • [3] Measurement and associated uncertainty evaluation for arm stretch of high precision centrifuge
    Ling Mingxiang
    Li Sizhong
    Zhang Rong
    Li Qisheng
    PROCEEDINGS OF THE FIFTH INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 AND 2, 2014, : 192 - 197
  • [4] Development of a measurement and control system of human centrifuge
    Liu, Wei
    Feng, Xue-Mei
    Deng, Jin-Hui
    Zhang, Li-Hong
    Wu, Bin
    Zhao, Wei
    Hangtian Yixue Yu Yixue Gongcheng/Space Medicine and Medical Engineering, 2003, 16 (03):
  • [5] An Innovative Short Arm Centrifuge for Future Studies on the Effects of Artificial Gravity on the Human Body
    Frett, Timo
    Mayrhofer, Michael
    Schwandtner, Johann
    Anken, Ralf
    Petrat, Guido
    MICROGRAVITY SCIENCE AND TECHNOLOGY, 2014, 26 (04) : 249 - 255
  • [6] An Innovative Short Arm Centrifuge for Future Studies on the Effects of Artificial Gravity on the Human Body
    Timo Frett
    Michael Mayrhofer
    Johann Schwandtner
    Ralf Anken
    Guido Petrat
    Microgravity Science and Technology, 2014, 26 : 249 - 255
  • [7] Cerebral circulation during mild plus Gz hypergravity by short-arm human centrifuge
    Iwasaki, Ken-ichi
    Ogawa, Yojiro
    Aoki, Ken
    Yanagida, Ryo
    JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (02) : 266 - 271
  • [8] Galanin and Adrenomedullin Plasma Responses During Artificial Gravity on a Human Short-Arm Centrifuge
    Winter, Julia
    Laing, Charles
    Johannes, Bernd
    Mulder, Edwin
    Brix, Bianca
    Roessler, Andreas
    Reichmuth, Johannes
    Rittweger, Joern
    Goswami, Nandu
    FRONTIERS IN PHYSIOLOGY, 2019, 9
  • [9] HUMAN CARDIOVASCULAR AND VESTIBULAR RESPONSES IN LONG MINUTES AND LOW +GZ LOADING BY A SHORT ARM CENTRIFUGE
    YAJIMA, K
    MIYAMOTO, A
    ITO, M
    MARU, R
    MAEDA, T
    SANADA, E
    NAKAZATO, T
    SAIKI, C
    YAMAGUCHI, Y
    IGARASHI, M
    MATSUMOTO, S
    ACTA ASTRONAUTICA, 1994, 33 : 239 - 252
  • [10] Gravity Threshold and Dose Response Relationships: Health Benefits Using a Short Arm Human Centrifuge
    Kourtidou-Papadeli, Chrysoula
    Frantzidis, Christos A.
    Gilou, Sotiria
    Plomariti, Christina E.
    Nday, Christiane M.
    Karnaras, Dimitrios
    Bakas, Lefteris
    Bamidis, Panagiotis D.
    Vernikos, Joan
    FRONTIERS IN PHYSIOLOGY, 2021, 12