Interdependent quality control of collocated seismometer and accelerometer

被引:0
|
作者
Izidor Tasič
机构
[1] Slovenian Environment Agency,
来源
Journal of Seismology | 2018年 / 22卷
关键词
Seismometer; Accelerometer; Side-by-side installation; Quality control; Error identification; Orientation misalignment; Sensitivity; Gain constant;
D O I
暂无
中图分类号
学科分类号
摘要
A new method for the interdependent quality control (IQC) of a collocated seismometer and accelerometer is presented. It is useful for seismic stations, where broadband seismometer and strong-motion accelerometer are installed side by side. The number of this type of seismic stations is growing and so is the number of activities associated with the quality control. With the IQC, the collocated seismometer and accelerometer are controlled with the single procedure. It is based on the calculation of transformation matrix which numerically transforms the detection of a seismic signal of accelerometer to the space of detection of seismometer. This matrix contains a lot of information; among them were also the “orientation misalignment,” “sensitivity corrections,” and two indicators, from which the quality of data and the error of systems can be identified. The procedure uses seismic signals, detected by both systems. The self-noise of commercial accelerometers is usually higher than the average seismic noise; therefore, a moderate shaking of the ground is needed. This type of shaking can come from stronger regional earthquakes. In this article, a mathematical description of the procedure is introduced first; then, a few examples with real data are presented. A critical error was discovered with the help of this algorithm. It cannot be identified by testing signals, injected from an acquisition unit into the STS-2 seismometer. There is also an example of serious orientation misalignment between a seismometer and an accelerometer.
引用
收藏
页码:1595 / 1612
页数:17
相关论文
共 50 条
  • [1] Interdependent quality control of collocated seismometer and accelerometer
    Tasic, Izidor
    JOURNAL OF SEISMOLOGY, 2018, 22 (06) : 1595 - 1612
  • [2] REFLEX KLYSTRON ACCELEROMETER AND SEISMOMETER
    SAWYER, GA
    ISHII, TK
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS AND CONTROL INSTRUMENTATION, 1969, IE16 (01): : 103 - &
  • [3] TELEMETERING BY REFLEX KLYSTRON ACCELEROMETER AND SEISMOMETER
    SAWYER, GA
    ISHII, TK
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1969, AES5 (04) : 681 - &
  • [4] Compact high-sensitivity accelerometer-seismometer
    Manukin, A. B.
    Gorshkov, A. N.
    Andreev, O. N.
    Shlyk, A. F.
    COSMIC RESEARCH, 2010, 48 (04) : 346 - 351
  • [5] Compact high-sensitivity accelerometer-seismometer
    A. B. Manukin
    A. N. Gorshkov
    O. N. Andreev
    A. F. Shlyk
    Cosmic Research, 2010, 48 : 346 - 351
  • [6] Otoliths - Accelerometer and seismometer; Implications in Vestibular Evoked Myogenic Potential (VEMP)
    Grant, Wally
    Curthoys, Ian
    HEARING RESEARCH, 2017, 353 : 26 - 35
  • [7] Improvement of a Uniaxial Seismic Accelerometer, an Integral Part of the Three-Axis Seismic Accelerometer SEM (ExoMars Seismometer)
    Manukin, A. B.
    Sayakina, N. F.
    Chernogorova, N. A.
    Ton'shev, A. K.
    Kalinnikov, I. I.
    SOLAR SYSTEM RESEARCH, 2024, 58 (04) : 404 - 408
  • [8] Phase errors in accelerometer arrays: An analysis based on collocated sensors and FEM
    Moschas, Fanis
    Mouzoulas, Dimitris
    Stiros, Stathis
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2015, 78 : 32 - 45
  • [9] Simple force balance accelerometer/seismometer based on a tuning fork displacement sensor
    Stuart-Watson, D
    Tapson, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (09): : 3045 - 3049
  • [10] Active damping of a beam using a physically collocated accelerometer and piezoelectric patch actuator
    Gatti, Gianluca
    Brennan, Michael J.
    Gardonio, Paolo
    JOURNAL OF SOUND AND VIBRATION, 2007, 303 (3-5) : 798 - 813