Comparison of the cost-effectiveness of stress myocardial perfusion MRI and SPECT in patients with suspected coronary artery disease

被引:11
|
作者
Iwata K. [1 ]
Ogasawara K. [2 ]
机构
[1] Section of Radiological Technology, Department of Medical Technology, Asahikawa Medical University Hospital, 2-1-1-1 Midorigaoka, Higashi, Asahikawa
[2] Faculty of Health Sciences, Hokkaido University, N12-W5 Kitaku, Sapporo Hokkaido
关键词
Coronary artery disease; Cost-benefit analysis; Magnetic resonance imaging; Myocardial perfusion; Tomography Emission-computed Single-photon;
D O I
10.1007/s12194-012-0165-2
中图分类号
学科分类号
摘要
Our aim in this study was to perform a cost-effectiveness analysis (CEA) to compare myocardial perfusion magnetic resonance imaging (p-MRI) and single photon emission computed tomography (SPECT) in the Japanese setting. The CEA of p-MRI and SPECT was performed from the payer's perspective. The subjects were outpatients who had chest pain, had no history of myocardial infarction, and showed normal or equivocal stress electrocardiogram findings. The costs of imaging techniques and treatments were assessed with the use of reimbursements of medical fees from Japanese healthcare insurance for the year 2007. Clinical effectiveness was defined in terms of the percent correct diagnosis of coronary artery disease (CAD). Data from published studies provided probabilities for the CEA, including the sensitivity and specificity of each imaging modality. We evaluated the cost-effectiveness ratio (CER) of p-MRI and SPECT using a decision tree model and compared the two. The CERs for diagnosis of CAD by p-MRI and SPECT were 1,988.2 and 2,582.0 Japanese Yen (JPY), respectively. The CERs for diagnosis and treatment of CAD by p-MRI and SPECT were 7,066.1 and 7,172.2 JPY, respectively. At a pre-test likelihood of CAD of 20-70 %, the CERs for diagnosis of CAD by p-MRI and SPECT were 1,476.8-3,364.3 and 2,107.3-3,957.7 JPY, respectively. For outpatients with chest pain, p-MRI had good clinical effectiveness and cost-effectiveness compared with SPECT. In the management of patients with suspected CAD, p-MRI is as useful as SPECT. © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:28 / 34
页数:6
相关论文
共 50 条
  • [1] Cost-effectiveness of Stress-MRI in Suspected Coronary Artery Disease
    von Knobelsdorff, Florian
    [J]. KARDIOLOGE, 2021, 15 (02): : 172 - 174
  • [2] Cost-effectiveness of myocardial perfusion imaging in the evaluation of patients with known or suspected coronary artery disease
    Shaw, LJ
    Berman, DS
    Miller, DD
    [J]. EUROPEAN HEART JOURNAL SUPPLEMENTS, 2001, 3 (0F) : F15 - F18
  • [3] Comparison of the cost-effectiveness of stress myocardial SPECT and stress echocardiography in suspected coronary artery disease considering the prognostic value of false-negative results
    Lee, DS
    Jang, MJ
    Cheon, GJ
    Chung, JK
    Lee, MC
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (05) : 515 - 522
  • [4] Comparison of the cost-effectiveness of stress myocardial SPECT and stress echocardiography in suspected coronary artery disease considering the prognostic value of false-negative results
    Dong Soo Lee
    Myoung Jin Jang
    Gi Jeong Cheon
    June-Key Chung
    Myung Chul Lee
    [J]. Journal of Nuclear Cardiology, 2002, 9 : 515 - 522
  • [5] Comparison of myocardial perfusion SPECT with ammonia PET for detection of myocardial ischemia in patients with suspected coronary artery disease
    Cho, Ihn Ho
    Kong, Eun-jung
    Chun, KyunghAh
    Park, Jong
    Shin, Dong-Gu
    Kim, Young-Jo
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [6] Cost-effectiveness of Coronary CT Angiography versus Myocardial Perfusion SPECT for Evaluation of Patients with Chest Pain and No Known Coronary Artery Disease
    Min, James K.
    Gilmore, Amanda
    Budoff, Matthew J.
    Berman, Daniel S.
    O'Day, Ken
    [J]. RADIOLOGY, 2010, 254 (03) : 801 - 808
  • [7] Increased cost-effectiveness of myocardial SPECT after consideration of benign prognosis of negative SPECT in suspected coronary artery disease.
    Lee, DS
    Jang, MJ
    Kang, KW
    Chung, JK
    Lee, MC
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 170P - 171P
  • [8] COST-EFFECTIVENESS ANALYSIS OF MYOSTRAIN IN SUSPECTED CORONARY ARTERY DISEASE PATIENTS
    Stojanovic, I
    Schneider, J. E.
    [J]. VALUE IN HEALTH, 2018, 21 : S216 - S216
  • [9] Probabilistic modelling of the cost-effectiveness of myocardial perfusion scintigraphy in coronary artery disease
    Underwood, S. R.
    Barwell, A.
    Basu, S.
    Chambers, M.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 528 - 529
  • [10] Cost-Effectiveness Analysis of Myocardial Perfusion SPECT and Coronary CT Angiography for the Diagnosis of Coronary Artery Disease in Diabetic Patients without Chest Pain
    Lim, I.
    Lee, W.
    Chang, H.
    Choi, S.
    Chae, I.
    Kim, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S254 - S254