WS2 quantum dots-MnO2 nanosheet system for use in ratiometric fluorometric/scattered light detection of glutathione
被引:0
|
作者:
Fanyong Yan
论文数: 0引用数: 0
h-index: 0
机构:Tiangong University,State Key Laboratory of Separation Membranes and Membrane Processes/National Center for International Joint Research on Separation Membranes, School of Chemistry and Chemical Engineering
Fanyong Yan
Zhonghui Sun
论文数: 0引用数: 0
h-index: 0
机构:Tiangong University,State Key Laboratory of Separation Membranes and Membrane Processes/National Center for International Joint Research on Separation Membranes, School of Chemistry and Chemical Engineering
Zhonghui Sun
Jinxia Xu
论文数: 0引用数: 0
h-index: 0
机构:Tiangong University,State Key Laboratory of Separation Membranes and Membrane Processes/National Center for International Joint Research on Separation Membranes, School of Chemistry and Chemical Engineering
Jinxia Xu
Hejing Li
论文数: 0引用数: 0
h-index: 0
机构:Tiangong University,State Key Laboratory of Separation Membranes and Membrane Processes/National Center for International Joint Research on Separation Membranes, School of Chemistry and Chemical Engineering
Hejing Li
Yuyang Zhang
论文数: 0引用数: 0
h-index: 0
机构:Tiangong University,State Key Laboratory of Separation Membranes and Membrane Processes/National Center for International Joint Research on Separation Membranes, School of Chemistry and Chemical Engineering
Yuyang Zhang
机构:
[1] Tiangong University,State Key Laboratory of Separation Membranes and Membrane Processes/National Center for International Joint Research on Separation Membranes, School of Chemistry and Chemical Engineering
Based on WS2 quantum dots (QDs) as fluorescent signals and MnO2 nanosheets as second-order scattering (SOS) signals, a combination of fluorescence and scattered light was used to construct a ratio sensing platform for glutathione (GSH) detection. When MnO2 nanosheets are added to WS2 QDs, the fluorescence of WS2 QDs is quenched by MnO2 nanosheets through IFE. Large-sized MnO2 nanosheets increase the SOS of the system and gradually approach the fluorescence. After adding GSH to WS2 QDs-MnO2, the MnO2 nanosheets were decomposed into Mn2+. The disappearance of the characteristic absorption peak of the MnO2 nanosheets suppressed the IFE to WS2 QDs, resulting in the fluorescence recovery of WS2 QDs. The reduction in size of MnO2 nanosheets after decomposition results in a decrease in the SOS of the system. Therefore, the ratio detection of GSH is obtained through the fluorescence and SOS dual signal response. Under optimal experimental conditions, the value of F406/S648 is linearly related to the GSH concentration in the range 0 to 60 μM, and the limit of detection (LOD) of GSH is 0.12 μM. In addition, the system is also used for the determination of GSH in real water samples and human serum, with good analytical results.
机构:
Jilin Univ, Coll Chem, Dept Analyt Chem, Changchun 130012, Jilin, Peoples R ChinaJilin Univ, Coll Chem, Dept Analyt Chem, Changchun 130012, Jilin, Peoples R China
Duan, Xinhe
Liu, Qing
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, Coll Chem, Dept Analyt Chem, Changchun 130012, Jilin, Peoples R ChinaJilin Univ, Coll Chem, Dept Analyt Chem, Changchun 130012, Jilin, Peoples R China
Liu, Qing
Wang, Guannan
论文数: 0引用数: 0
h-index: 0
机构:
Jinzhou Med Univ, Dept Chem, Jinzhou 121001, Peoples R China
Jinzhou Med Univ, Key Lab Med Tissue Engn Liaoning Prov, Jinzhou 121001, Peoples R ChinaJilin Univ, Coll Chem, Dept Analyt Chem, Changchun 130012, Jilin, Peoples R China
Wang, Guannan
Su, Xingguang
论文数: 0引用数: 0
h-index: 0
机构:
Jilin Univ, Coll Chem, Dept Analyt Chem, Changchun 130012, Jilin, Peoples R ChinaJilin Univ, Coll Chem, Dept Analyt Chem, Changchun 130012, Jilin, Peoples R China