Prevention of phase-to-phase short circuit in turbogenerators with water cooling windings

被引:0
|
作者
Antonyuk O.V.
Vakser B.D.
Gusev N.A.
Kadi-Ogly I.A.
Chibrikov A.N.
机构
关键词
Air drying; Connection insulation; Dc component; Ground short circuit; Phase-to-phase short circuit; Wetting;
D O I
10.3103/S1068371209030067
中图分类号
学科分类号
摘要
The most severe crash of a generator with a water-cooling stator winding is a phase-to-phase short circuit caused by hydraulic hermeticity failure and insulation wetting. The means of detecting insulation wetting in proper time and preventing a phase-to-phase short circuit are described. © 2009 Allerton Press, Inc.
引用
收藏
页码:142 / 144
页数:2
相关论文
共 50 条
  • [1] Penetration level calculation with considerations of phase-to-phase short circuit fault
    Zhejiang University, Hangzhou 310027, China
    不详
    不详
    [J]. Dianli Xitong Zidonghue, 2008, 3 (82-86): : 82 - 86
  • [2] Influence of distributed generation on phase-to-phase short circuit protection in distribution network
    Zhejiang University, Hangzhou 310027, China
    不详
    不详
    [J]. Dianli Xitong Zidonghue, 2008, 1 (93-97):
  • [3] Phase-to-phase Short Circuit Fault Between Same Group of Star-connected Phase Windings in Twelve-phase Synchronous Generator with Rectifier Load System
    Sun, Yuguang
    Huang, Ziguo
    Wang, Shanming
    Mu, Shujun
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2017, 41 (08): : 153 - 158
  • [4] PMSM MODEL WITH PHASE-TO-PHASE SHORT-CIRCUIT AND DIAGNOSIS BY ESA AND EPVA
    Bouchareb, Chourouk
    Said, Mohamed Said Nait
    [J]. ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2016, 14 (05) : 522 - 530
  • [5] Analysis of Open Phase and Phase-to-Phase Short Circuit Fault of PMSM for Electrical Propulsion in an eVTOL
    Ramoul, John
    Watthewaduge, Gayan
    Callegaro, Alan Dorneles
    Nahid-Mobarakeh, Babak
    Baronian, Armen
    Emadi, Ali
    [J]. IECON 2021 - 47TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2021,
  • [6] Analysis on the distribution network with distributed generators under phase-to-phase short-circuit faults
    [J]. Wang, G. (wg_scut@263.net), 1600, Chinese Society for Electrical Engineering (33):
  • [7] Equations of electric motor power supply unit dissymmetry under phase-to-phase short-circuit fault
    Tchaban, V. Y.
    Tchaban, O., V
    [J]. ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2013, (05) : 48 - 49
  • [8] Analysis of Stator Internal Phase-to-Phase Short Circuit in the 12-Phase Synchronous Generator With Rectifier-Load System
    Wang, Shanming
    Sun, Yuguang
    Huang, Ziguo
    Mu, Shujun
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (01) : 299 - 311
  • [9] An online groundwall and phase-to-phase insulation quality assessment technique for AC-machine stator windings
    Lee, Sang Bin
    Yang, Jinkyu
    Younsi, Karim
    Bharadwaj, Raj Mohan
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (04) : 946 - 957
  • [10] Distance Protection Based on Negative-sequence Impedance Reconstruction for Phase-to-phase Short Circuit of Renewable Power Plant Transmission Lines
    Chao, Chenxu
    Zheng, Xiaodong
    Tai, Nengling
    Ye, Hai
    Liu, Hulin
    Han, Jun
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (22): : 101 - 109