Selective sensing of mercury(II) using PVC-based membranes incorporating recently synthesized 1,3-alternate thiacalix[4]crown ionophore

被引:0
|
作者
Rakesh Kumar Mahajan
Ajar Kamal
Naresh Kumar
Vandana Bhalla
Manoj Kumar
机构
[1] Guru Nanak Dev University,Department of Chemistry, UGC
关键词
1,3-Alternate thiacalix[4]crown; Polymeric membrane electrode; Coated graphite electrode; Selectivity; Indicator electrode;
D O I
暂无
中图分类号
学科分类号
摘要
The construction and electrodes characteristics of poly(vinylchloride) (PVC)-based polymeric membrane electrode (PME) and coated graphite electrode (CGE), incorporating 1,3-alternate thiacalix[4]crown as ionophore for estimation of Hg(II) ions, are reported here. The best potential response was observed for PME-1 having membrane composition of: ionophore (6.2 mg), PVC (100.0 mg), 2-nitrophenyl octyl ether (2-NPOE; 200.0 mg), and sodium tetraphenyl borate (NaTPB; 2.0 mg); for CGE-1 with the membrane composition: ionophore (3.5 mg), PVC (40.0 mg), 2-NPOE (80.0 mg), and NaTPB (2.0 mg). The electrodes exhibits Nernstian slope of 29.16 mV/decade with PME-1 and 30.39 mV/decade with CGE-1 for Hg(II) ions over wide concentration range, i.e., 1.0 × 10−1 to 5.0 × 10−6 M with PME-1 and 1.0 × 10−1 to 5.0 × 10−7 M with CGE-1. Lower detection limits were found to be 9.77 × 10−6 M for PME-1 and 7.76 × 10−7 M for CGE-1 with response time varying from 10 to 20 s. Also, these electrodes work within pH range of 2.0–6.0 for PME-1 and 1.5–6.5 for CGE-1. Overall, CGE-1 has been found to be better than PME-1. CGE-1 has been used as indicator electrode for the potentiometric titration of Hg(II) ions with EDTA as well as successfully applied for determination of Hg(II) content in wastewater, insecticide, dental amalgam, and ayurvedic medicines samples with very good performance (0.9974 correlation coefficient in the comparison against volumetric method).
引用
收藏
页码:3086 / 3097
页数:11
相关论文
共 6 条
  • [1] Selective sensing of mercury(II) using PVC-based membranes incorporating recently synthesized 1,3-alternate thiacalix[4]crown ionophore
    Mahajan, Rakesh Kumar
    Kamal, Ajar
    Kumar, Naresh
    Bhalla, Vandana
    Kumar, Manoj
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (05) : 3086 - 3097
  • [2] Cesium ion-selective electrodes based on 1,3-alternate thiacalix[4]biscrown-6,6
    Choi, Y
    Kim, H
    Lee, JK
    Lee, SH
    Lim, HB
    Kim, JS
    TALANTA, 2004, 64 (04) : 975 - 980
  • [3] A study of allosteric binding behaviour of a 1,3-alternate thiacalix[4]arene-based receptor using fluorescence signal
    Tomiyasu, Hirotsugu
    Jin, Cheng-Cheng
    Ni, Xin-Long
    Zeng, Xi
    Redshaw, Carl
    Yamato, Takehiko
    ORGANIC & BIOMOLECULAR CHEMISTRY, 2014, 12 (27) : 4917 - 4923
  • [4] Selective recognition of Thallium(I) by 1,3-alternate calix[4]arene-bis(crown-6 ether):: A new talent of the known ionophore
    Roper, Ebony D.
    Talanov, Vladimir S.
    Butcher, Raymond J.
    Talanova, Galina G.
    SUPRAMOLECULAR CHEMISTRY, 2008, 20 (1-2) : 217 - 229
  • [5] Optical sensing of cesium using 1,3-alternate calix[4]-mono- and di(anthrylmethyl)aza-crown-6
    Ji, HF
    Dabestani, R
    Hettich, RL
    Brown, GM
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1999, 70 (06) : 882 - 886
  • [6] A new Hg2+-Selective fluorescent sensor based on a 1,3-alternate thiacalix[4]arene anchored with four 8-quinolinoloxy groups
    Praveen, L.
    Ganga, V. B.
    Thirumalai, R.
    Sreeja, T.
    Reddy, M. L. P.
    Varma, R. Luxmi
    INORGANIC CHEMISTRY, 2007, 46 (16) : 6277 - 6282