Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions

被引:0
|
作者
Matthias Eiber
Axel Martinez-Möller
Michael Souvatzoglou
Konstantin Holzapfel
Anja Pickhard
Dennys Löffelbein
Ivan Santi
Ernst J. Rummeny
Sibylle Ziegler
Markus Schwaiger
Stephan G. Nekolla
Ambros J. Beer
机构
[1] Technische Universität München,Department of Radiology, Klinikum rechts der Isar
[2] Technische Universität München,Department of Nuclear Medicine
[3] Technische Universität München,Department of Otorhinolaryngology
[4] Technische Universität München,Department of Maxillofacial Surgery
[5] University of Bologna,Service of Nuclear Medicine, PET Center, Policlinico S.Orsola
关键词
Attenuation correction; Dixon-based VIBE T1-weighted MR sequence; Localization; Low-dose CT; MR/PET;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1691 / 1701
页数:10
相关论文
共 50 条
  • [1] Value of a Dixon-based MR/PET attenuation correction sequence for the localization and evaluation of PET-positive lesions
    Eiber, Matthias
    Martinez-Moeller, Axel
    Souvatzoglou, Michael
    Holzapfel, Konstantin
    Pickhard, Anja
    Loeffelbein, Dennys
    Santi, Ivan
    Rummeny, Ernst J.
    Ziegler, Sibylle
    Schwaiger, Markus
    Nekolla, Stephan G.
    Beer, Ambros J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (09) : 1691 - 1701
  • [2] Value of a Dixon based MR-PET attenuation correction sequence for the localization and evaluation of PET positive lesions
    Eiber, Matthias
    Martinez-Moeller, Axel
    Souvatzoglou, Michael
    Rummeny, Ernst
    Schwaiger, Markus
    Beer, Ambros
    Nekolla, Stephan
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [3] Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions
    Jeong J.H.
    Cho I.H.
    Kong E.J.
    Chun K.A.
    Nuclear Medicine and Molecular Imaging, 2014, 48 (1) : 26 - 32
  • [4] Dental artifacts in the head and neck region: implications for Dixon-based attenuation correction in PET/MR
    Ladefoged C.N.
    Hansen A.E.
    Keller S.H.
    Fischer B.M.
    Rasmussen J.H.
    Law I.
    Kjær A.
    Højgaard L.
    Lauze F.
    Beyer T.
    Andersen F.L.
    EJNMMI Physics, 2 (1) : 1 - 15
  • [5] PET-MR Attenuation Correction using 3D Multi-Echo Dixon-Based UTE Sequence
    Han, Paul
    Horng, Debra
    Lai, Xiaochun
    El Fakhri, Georges
    Ouyang, Jinsong
    Ma, Chao
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [6] Evaluation of fatty liver with Dixon sequence for attenuation correction and FDG uptake in PET/ MR
    Choi, Ihn Ho
    Kong, Eun Jung
    Chun, Kyung Ah
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [7] Reproducibility of MRI Dixon-Based Attenuation Correction in Combined PET/MR with Applications for Lean Body Mass Estimation
    Rausch, Ivo
    Rust, Petra
    DiFranco, Matthew D.
    Lassen, Martin
    Stadlbauer, Andreas
    Mayerhoefer, Marius E.
    Hartenbach, Markus
    Hacker, Marcus
    Beyer, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1096 - 1101
  • [8] The effect of gadolinium enhancement on cardiac PET / MR imaging based on MR-Dixon attenuation correction sequence
    Liu, Jiajin
    Bi, Xiao
    Guan, Zhiwei
    An, Jing
    Dong, Wei
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [9] Clinical issues regarding misclassification by Dixon based PET/MR attenuation correction
    Kong, Eunjung
    Cho, Ihnho
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2015, 18 (01): : 42 - 47
  • [10] Lean body mass estimation from standard, Dixon-based attenuation correction in combined PET/MRI
    Rausch, I.
    Rust, P.
    DiFranco, M. D.
    Lassen, M.
    Stadlbauer, A.
    Mayerhoefer, M. E.
    Hartenbach, M.
    Beyer, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S17 - S18