Quantitative comparisons between relaxation enhanced compressed sensing 3D MERGE and conventional 3D MERGE for vessel wall imaging in equal scan time: preliminary studies

被引:0
|
作者
Bo Li
Hao Li
Li Dong
机构
[1] The Third Affiliated Hospital of Nanchang University,Center Laboratory
[2] The Third Affiliated Hospital of Nanchang University,Jiangxi Key Laboratory of Cancer Metastasis and Precision Treatment
[3] University of Cambridge,Department of Radiology
[4] Capital Medical University,Department of Radiology, Beijing Anzhen Hospital
来源
关键词
RECS-3D MERGE; black-blood MR imaging; compressed sensing; pseudo-centric phase encoding order;
D O I
暂无
中图分类号
学科分类号
摘要
In this study, we quantitatively compared relaxation enhanced compressed sensing (RECS-3D MERGE) with conventional 3D MERGE techniques on blood suppression efficiency, wall-lumen contrast and plaque burden measurement for carotid atherosclerotic imaging in equal scan time. Twelve patients were recruited in the study. RECS-3D MERGE and conventional 3D MERGE were implemented. 2D DIR-FSE was carried out as a reference standard. The lumen signal-to-tissue ratio (STR) was used as the quantitative measure of blood suppression efficiency. The contrast-to-tissue ratio (CTR) was used as the quantitative measure of wall-lumen contrast. Vessel lumen area (LA) and wall area (WA) were measured for morphological comparisons. The lumen STR of RECS-3D MERGE was significantly lower than that of 3D MERGE while the wall-lumen CTR of RECS-3D MERGE was significantly higher. There were no significant differences in plaque burden measurements between RECS-3D MERGE and 2D DIR-FSE. For comparison between conventional 3D MERGE and 2D DIR-FSE, there were no significant differences in LA measurement. However, the WA of 3D MERGE was significantly larger. The RECS-3D MERGE sequence achieved more sufficient blood suppression and higher image contrast without prolonging the scan time. These improvements lead to more accurate morphological measurements of carotid atherosclerotic imaging.
引用
收藏
页码:1683 / 1691
页数:8
相关论文
共 50 条
  • [1] Quantitative comparisons between relaxation enhanced compressed sensing 3D MERGE and conventional 3D MERGE for vessel wall imaging in equal scan time: preliminary studies
    Bo Li
    Hao Li
    Li Dong
    [J]. Science China(Life Sciences)., 2019, 62 (12) - 1691
  • [2] Quantitative comparisons between relaxation enhanced compressed sensing 3D MERGE and conventional 3D MERGE for vessel wall imaging in equal scan time: preliminary studies
    Li, Bo
    Li, Hao
    Dong, Li
    [J]. SCIENCE CHINA-LIFE SCIENCES, 2019, 62 (12) : 1683 - 1691
  • [3] Quantitative comparisons between relaxation enhanced compressed sensing 3D MERGE and conventional 3D MERGE for vessel wall imaging in equal scan time: preliminary studies
    Bo Li
    Hao Li
    Li Dong
    [J]. Science China Life Sciences, 2019, (12) : 1683 - 1691
  • [4] Accelerated 3D MERGE carotid imaging using compressed sensing with a hidden markov tree model
    Makhijani, Mahender K.
    Balu, Niranjan
    Yamada, Kiyofumi
    Yuan, Chun
    Nayak, Krishna S.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1194 - 1202
  • [5] Accelerated Quantitative 3D UTE-Cones Imaging Using Compressed Sensing
    Athertya, Jiyo S.
    Ma, Yajun
    Afsahi, Amir Masoud
    Lombardi, Alecio F.
    Moazamian, Dina
    Jerban, Saeed
    Sedaghat, Sam
    Jang, Hyungseok
    [J]. SENSORS, 2022, 22 (19)
  • [6] Compressed Sensing for THz FMCW Radar 3D Imaging
    Gu, Shanshan
    Xi, Guangrong
    Ge, Lingyu
    Yang, Zhong
    Wang, Yizhi
    Chen, Weina
    Yu, Zhenzhong
    [J]. COMPLEXITY, 2021, 2021
  • [7] Plaque Morphologic Quantification Reliability of 3D Whole-Brain Vessel Wall Imaging in Patients With Intracranial Atherosclerotic Disease: A Comparison With Conventional 3D Targeted Vessel Wall Imaging
    Zhang, Na
    Liu, Xinfeng
    Xiao, Jiayu
    Song, Shlee S.
    Fan, Zhaoyang
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (01) : 166 - 174
  • [8] A Study on Different 3D Body Scan Data Merge Processing Method based on Axillary Data
    Cui, Ming-Hai
    Zheng, Rong
    Zhang, Hao
    [J]. TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM PROCEEDINGS, VOLS 1-3, 2011, : 99 - 104
  • [9] Compressed Sensing for Portable Millimeter Wave 3D Imaging Radar
    Zhang, Renyuan
    Cao, Siyang
    [J]. 2017 IEEE RADAR CONFERENCE (RADARCONF), 2017, : 663 - 668
  • [10] Accelerated 3D Coronary Vessel Wall MR Imaging Based on Compressed Sensing with a Block-Weighted Total Variation Regularization
    Zhongzhou Chen
    Xiaoyong Zhang
    Caiyun Shi
    Shi Su
    Zhaoyang Fan
    Jim X. Ji
    Guoxi Xie
    Xin Liu
    [J]. Applied Magnetic Resonance, 2017, 48 : 361 - 378