Assessment of the adequacy of bronchial stenting by flow-volume loops

被引:0
|
作者
Clare A. McLaren
Nick Pigott
Catherine Dunne
Martin J. Elliott
Derek J. Roebuck
机构
[1] Great Ormond Street Hospital for Children,Department of Radiology
[2] Great Ormond Street Hospital for Children,Cardiothoracic Unit
[3] Great Ormond Street Hospital for Children,Department of Physiotherapy
来源
Pediatric Radiology | 2006年 / 36卷
关键词
Airway obstruction; Bronchus; Stent; Respiratory physiology; Infant;
D O I
暂无
中图分类号
学科分类号
摘要
Airway compression is a common problem in children with certain forms of congenital heart disease. Although various surgical approaches are available to overcome this form of airway obstruction, internal stenting is necessary in a minority of patients. It can be difficult to assess the success of stenting at the time of the procedure, and the interval to successful extubation is usually used as an outcome measure. Measurement of relevant parameters of respiratory physiology with flow-volume and volume-pressure loops permits immediate quantitative assessment of the adequacy of stenting. A 3-month-old infant who underwent bronchial stenting and physiological assessment at the time of the procedure is described.
引用
收藏
页码:860 / 862
页数:2
相关论文
共 50 条
  • [1] Assessment of the adequacy of bronchial stenting by flow-volume loops
    McLaren, Clare A.
    Pigott, Nick
    Dunne, Catherine
    Elliott, Martin J.
    Roebuck, Derek J.
    PEDIATRIC RADIOLOGY, 2006, 36 (08) : 860 - 862
  • [2] LOOPS AND NO FLOW-VOLUME CURVES
    RODRIGUEZROISIN, R
    MEDICINA CLINICA, 1980, 75 (04): : 177 - 177
  • [3] POSTOPERATIVE FLOW-VOLUME LOOPS
    MORTON, A
    HANSEN, P
    BAKER, AB
    ANAESTHESIA AND INTENSIVE CARE, 1977, 5 (02) : 146 - 148
  • [4] Flow-volume loops:: clinical correlation
    Diaz, Jose Luis
    Casal, Jesus
    Rodriguez-Cintron, William
    PUERTO RICO HEALTH SCIENCES JOURNAL, 2008, 27 (02) : 181 - 182
  • [5] OBSERVATIONS ON RESPIRATORY FLOW-VOLUME LOOPS
    WEITZNER, SW
    BERENYI, KJ
    HARMEL, MH
    BRITISH JOURNAL OF ANAESTHESIA, 1968, 40 (10) : 716 - &
  • [6] DIURNAL-VARIATION IN BRONCHIAL RESPONSIVENESS TO METHACHOLINE DEMONSTRATED BY PARTIAL FLOW-VOLUME LOOPS
    HEATON, RW
    GILLETT, MK
    SNASHALL, PD
    CLINICAL SCIENCE, 1987, 72 : P85 - P85
  • [7] FLOW-VOLUME LOOPS, BY THEMSELVES, ARE INADEQUATE FOR SPIROMETRY
    Morris, A.
    Linares, O.
    Hegewald, M.
    RESPIROLOGY, 2016, 21 : 135 - 135
  • [8] FLOW-VOLUME LOOPS UNDER MECHANICAL VENTILATION
    RUBI, JAG
    SANMARTIN, A
    DIAZ, GG
    TORRES, G
    APEZTEGUIA, C
    CRITICAL CARE MEDICINE, 1981, 9 (03) : 273 - 273
  • [9] FLOW-VOLUME LOOPS IN NEWBORN-INFANTS
    WISE, PH
    KRAUSS, AN
    WALDMAN, S
    AULD, PAM
    CRITICAL CARE MEDICINE, 1980, 8 (02) : 61 - 63
  • [10] FLOW-VOLUME LOOPS TO ASSESS AIRWAY-OBSTRUCTION
    BOUSHEY, HA
    NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (03): : 175 - 175