An inter-laboratory comparison for determination of cortisol in saliva

被引:0
|
作者
A. H. Garde
Åse Marie Hansen
Thomas Block Nikolajsen
机构
[1] National Institute of Occupational Health,
[2] Lersø Parkallé 105,undefined
[3] 2100 Copenhagen Ø,undefined
[4] Denmark e-mail: ahg@ami.dk Tel.: +45-39165200 Fax: +45-39165201,undefined
来源
关键词
Keywords Method comparison; External quality control; Cortisol; Saliva;
D O I
暂无
中图分类号
学科分类号
摘要
An inter-laboratory comparison study for cortisol in saliva is reported in the present study. Nine laboratories representing four different methods participated in the study. Each laboratory measured five blind samples prepared from natural saliva spiked with a pure certified reference material in the range 0–70 nmol/L. The average observed values were established as means of eight laboratories, because one laboratory was excluded as an outlier. The natural content of cortisol in the pooled saliva was 6.8 nmol/L. The recovery of the certified reference material was 83%–131% (164% for the outlying laboratory). For five laboratories the 95%-confidence intervals of the recoveries did not cover 100%. The standard deviations for a concentration of 10 nmol/L were estimated for each laboratory. They were 0.64–1.67 nmol/L (6.26 nmol/L for the outlying laboratory). The present study emphasizes the need for an external proficiency-testing scheme and a certified reference material for cortisol in saliva.
引用
收藏
页码:16 / 20
页数:4
相关论文
共 50 条
  • [1] An inter-laboratory comparison for determination of cortisol in saliva
    Garde, AH
    Hansen, ÅM
    Nikolajsen, TB
    ACCREDITATION AND QUALITY ASSURANCE, 2003, 8 (01) : 16 - 20
  • [2] INTER-LABORATORY COMPARISON OF RADIOIMMUNOLOGICAL CALCITONIN DETERMINATION
    RAUE, F
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1982, 20 (03): : 157 - 161
  • [3] INTER-LABORATORY COMPARISON OF TOTAL SERUM TRIIODOTHYRONINE DETERMINATION
    GORDON, A
    GROSS, J
    ACTA ENDOCRINOLOGICA, 1976, 83 (03): : 539 - 548
  • [5] Pleural adenosine deaminase determination: An inter-laboratory comparison is required
    Delacour, Herve
    Bousquet, Aurore
    Fontan, Eleonore
    Ceppa, Franck
    JOURNAL OF INFECTION, 2014, 68 (01) : 103 - 103
  • [6] Inter-laboratory measurements and inter-laboratory cooperation
    Mudronja, V
    Stepanic, J
    Medic, S
    MEASURE AND QUALITY CONTROL IN PRODUCTION, 2004, 1860 : 745 - 750
  • [7] INTER-LABORATORY COMPARISON OF FLUOROCARBON MEASUREMENTS
    RASMUSSEN, RA
    ATMOSPHERIC ENVIRONMENT, 1978, 12 (12) : 2505 - 2508
  • [8] THE CHEMAQUA INTER-LABORATORY COMPARISON PROGRAM
    MATTINGLEY, BI
    TRACE ELEMENTS IN NEW ZEALAND : ENVIRONMENTAL, HUMAN AND ANIMAL, 1989, : 275 - 285
  • [9] INTER-LABORATORY COMPARISON OF NORTRIPTYLINE LEVELS
    BURROWS, GD
    DAVIES, B
    MAGUIRE, KP
    NORMAN, TR
    SCOGGINS, BA
    HULLIN, RP
    BURCH, J
    BIOCHEMICAL MEDICINE, 1978, 20 (01): : 125 - 127
  • [10] An Inter-Laboratory Comparison of NVNA Measurements
    Salter, Martin
    Stant, Laurence
    Buisman, Koen
    Nielsen, Troels
    INTERNATIONAL WORKSHOP ON INTEGRATED NONLINEAR MICROWAVE AND MILLIMETRE-WAVE CIRCUITS (INMMIC), 2018,