The effectiveness of geothermal systems in cooling residential buildings: a case study of a residential building in Alexandria, Egypt

被引:0
|
作者
Fouad, Heba [1 ,2 ]
Mahmoud, Ayman H. [1 ]
Moussa, Rania Rushdy [3 ]
机构
[1] Architecture Department, Faculty of Engineering, Cairo University, Giza, Egypt
[2] Architecture Department, Faculty of Engineering, The Higher Institute of Engineering in El-Shorouk, Cairo, Egypt
[3] Architecture Department, Faculty of Engineering, The British University in Egypt, Cairo, Egypt
来源
关键词
Air conditioning - Atmospheric temperature - Carbon - Cooling systems - Energy utilization - Floors - Geothermal fields - Housing - Sustainable development - Thermal comfort;
D O I
10.1186/s44147-024-00378-x
中图分类号
学科分类号
摘要
The urbanization of cities, the corroding of green areas, and the increasing demand for electric energy lead to the formation of heat islands in cities and the appearance of the global climate change phenomenon. Therefore, it was necessary to resort to the use of renewable energy sources, such as geothermal energy, to be used in different applications, as it can be used to cool buildings in cities during the summer. This research deals with the benefits of using geothermal energy systems, their different types, and the possibility of their application in Egypt. Also discussing the effectiveness of the vertical closed geothermal system in residential buildings in Alexandria Governorate in Egypt to reach an answer to a question. The effectiveness of the geothermal energy system in residential buildings is to reduce the problem of rising temperatures, energy consumption for cooling, and carbon emissions and thus reduce the problem of the formation of heat islands in cities and the appearance of the global climate change phenomenon and reaching a sustainable, environmentally friendly building that achieves thermal comfort for humans through the use of a simulation program called TRNSYS-17, through which the current situation of the building was compared and the addition of a vertical closed geothermal system was assumed, the extent of its effectiveness was compared in the whole building, and the cost of a vertical closed geothermal system and a traditional air conditioning system (HVAC) in a building was compared (case study). Hence, the efficiency of the vertical closed geothermal system appeared to reduce electric energy consumption and carbon emissions in the whole building at Alexandria in Egypt, especially the ground floor, which reached thermal comfort for humans and worked to reduce electricity consumption and carbon emissions by up to 22.93% in the building as a whole. © The Author(s) 2024.
引用
收藏
相关论文
共 50 条
  • [1] PASSIVE COOLING SYSTEMS IN RESIDENTIAL BUILDINGS
    INGERSOLL, JG
    GIVONI, B
    [J]. AIP CONFERENCE PROCEEDINGS, 1985, (135) : 209 - 228
  • [2] Indoor exposure of elderly to air pollutants in residential buildings in Alexandria, Egypt
    Abdel-Salam, Mahmoud M. M.
    [J]. BUILDING AND ENVIRONMENT, 2022, 219
  • [3] Assessing livability of residential streets - Case study: El-Attarin, Alexandria, Egypt
    Elsawy, Ahmed Atef
    Ayad, Hany M.
    Saadallah, Dina
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2019, 58 (02) : 745 - 755
  • [4] How do people select their residential locations in Egypt? The case of Alexandria
    Ibrahim, Mohamed R.
    [J]. CITIES, 2017, 62 : 96 - 106
  • [5] Investigation of optimal heating and cooling systems in residential buildings
    Boiling, Angela L.
    Mathias, James A.
    [J]. ASHRAE TRANSACTIONS 2008, VOL 114, PT 1, 2008, 114 : 128 - 139
  • [6] Environmental life cycle assessment of a residential building in Egypt: A case study
    Ali, Ahmed AbdelMonteleb M.
    Negm, Abdelazim M.
    Bady, Mahmoud F.
    Ibrahim, Mona G. E.
    [J]. 8TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING, INTER-ENG 2014, 2015, 19 : 349 - 356
  • [7] VENTILATION COOLING OF RESIDENTIAL BUILDINGS
    KAMMERUD, R
    ANDERSSON, B
    PLACE, W
    CEBALLOS, E
    CURTIS, B
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (12): : 55 - 55
  • [8] Assessment of ventilation effectiveness in exiting residential building in mediterranean countries: Case study, existing residential building in Portugal
    Salehi, Atefeh
    Torres, Isabel
    Ramose, Ana
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2017, 32 : 496 - 507
  • [9] An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
    Salehi, Atefeh
    Torres, Isable
    Ramos, Ana
    [J]. Sustainable Built Environment Tallinn and Helsinki Conference SBE16 Build Green and Renovate Deep, 2016, 96 : 613 - 619
  • [10] Energy efficiency and cost effectiveness of low depth geothermal heating and cooling for non-residential buildings.
    Eicker, Ursula
    Thumm, Felix
    [J]. BAUPHYSIK, 2012, 34 (01) : 11 - 18