GESPECOR: A versatile tool in gamma-ray spectrometry

被引:0
|
作者
O. Sima
D. Arnold
C. Dovlete
机构
[1] Bucharest University,Physics Department
[2] Physikalisch-Technische Bundesanstalt,undefined
[3] Environmental Radioactivity Laboratory,undefined
关键词
Physical Chemistry; Inorganic Chemistry; Matrix Effect; Summing; Versatile Tool;
D O I
暂无
中图分类号
学科分类号
摘要
GESPECOR is a Monte Carlo based software developed for the computation of efficiency, of matrix effects and of coincidence summing effects in gamma-ray spectrometry. GESPECOR can be applied to coaxial and well-type HPGe or to Ge(Li) detectors and to various types of sources, including point, cylindrical, and spherical sources or Marinelli beakers. In this paper the structure of GESPECOR is presented and the procedures applied are described. The uncertainty of the results computed by GESPECOR is carefully analyzed. The analysis shows that GESPECOR is able to provide results with a well defined uncertainty, in a user friendly WINDOWS environment.
引用
收藏
页码:359 / 364
页数:5
相关论文
共 50 条
  • [1] GESPECOR: A versatile tool in gamma-ray spectrometry
    Sima, O
    Arnold, D
    Dovlete, C
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2001, 248 (02) : 359 - 364
  • [2] Comparison of LabSOCS and GESPECOR codes used in gamma-ray spectrometry
    Done, L.
    Tugulan, L. C.
    Gurau, D.
    Dragolici, F.
    Alexandru, C.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 539 - 543
  • [3] Gamma-ray spectrometry as versatile tool in soil science: A critical review
    Reinhardt, Nadja
    Herrmann, Ludger
    JOURNAL OF PLANT NUTRITION AND SOIL SCIENCE, 2019, 182 (01) : 9 - 27
  • [4] Monte Carlo simulation by GEANT 4 and GESPECOR of in situ gamma-ray spectrometry measurements
    Chirosca, Alecsandru
    Suvaila, Rares
    Sima, Octavian
    APPLIED RADIATION AND ISOTOPES, 2013, 81 : 87 - 91
  • [5] A new versatile underground gamma-ray spectrometry system
    Lutter, Guillaume
    Hult, Mikael
    Marissens, Gerd
    Andreotti, Erica
    Rosengard, Ulf
    Misiaszek, Marcin
    Yuksel, Ayhan
    Sahin, Namik
    APPLIED RADIATION AND ISOTOPES, 2013, 81 : 81 - 86
  • [6] Transfer of the efficiency calibration of Germanium gamma-ray detectors using the GESPECOR software
    Sima, O
    Arnold, D
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 71 - 75
  • [7] GAMMA-RAY SPECTROMETRY AS A TOOL FOR A RAPID INVESTIGATION OF DETRITIC CORES
    CHENOUARD, L
    LALOU, C
    JOURNAL OF SEDIMENTARY PETROLOGY, 1969, 39 (04): : 1477 - +
  • [8] GE(LI) GAMMA-RAY SPECTROMETRY AS A PILOT FOR NAI(TI) GAMMA-RAY SPECTROMETRY
    GUINN, VP
    GRABER, FM
    FLEISHMAN, DM
    TALANTA, 1968, 15 (11) : 1159 - +
  • [9] Traceability in gamma-ray spectrometry
    Glavic-Cindro, D.
    Korun, M.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1196 - 1199
  • [10] Underground gamma-ray spectrometry
    Hult, M
    Preusse, W
    Gasparro, J
    Köhler, M
    ACTA CHIMICA SLOVENICA, 2006, 53 (01) : 1 - 7