Design of a compact long counter with an improved response using multiple point-like thermal neutron counters

被引:0
|
作者
Pengxiang Wang
Zhimeng Hu
Xucheng Ma
Pin Gong
Guoqiang Zhong
Giuseppe Gorini
Baolong Chen
Xiaobin Tang
机构
[1] Nanjing University of Aeronautics and Astronautics,Department of Nuclear Science and Technology
[2] Nanjing University of Aeronautics and Astronautics,Key Laboratory of Nuclear Technology Application and Radiation Protection in Astronautics, Ministry of Industry and Information Technology
[3] Chinese Academy of Sciences,Institute of Plasma Physics
[4] University of Milan-Bicocca,Department of Physics
[5] Nuclear and Radiation Safety Center,undefined
[6] Ministry of Ecology and Environment,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A long counter with multiple point-like thermal neutron counters positioned in a cylindrical neutron moderator was investigated to improve the performance of the long counter, including flatter fluence response in a wider neutron energy range and also the compactness. The summation of the weighted counts of each thermal neutron counter yields the response of the long counter. In this study, silicon carbide (SiC) coated with 6LiF convertor was used as the thermal neutron counter. In a further effort to balance the performance and structural complexity of long counters with multiple thermal neutron counters, the number and positions of these counters were first studied and optimized. As a result, the long counter with four specially positioned SiC counters showed the best performance. Besides, we also implemented a copper annular into the moderator to compensate for the long counter’s response above a few MeV. The response function was relatively flat in the energy range from 10 eV to 25 MeV, with a relative standard deviation of approximately 1.78%. In addition, the proposed detector can evaluate the neutron energy, allowing it to monitor neutron fluence and neutron energy simultaneously.
引用
收藏
相关论文
共 11 条
  • [1] Design of a compact long counter with an improved response using multiple point-like thermal neutron counters
    Wang, Pengxiang
    Hu, Zhimeng
    Ma, Xucheng
    Gong, Pin
    Zhong, Guoqiang
    Gorini, Giuseppe
    Chen, Baolong
    Tang, Xiaobin
    EUROPEAN PHYSICAL JOURNAL PLUS, 2023, 138 (05):
  • [2] Response improved for neutron long counter
    Li, Yanan
    Li, Taosheng
    Song, Gang
    Mazunga, Mohamed
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 93 - 96
  • [3] THE DESIGN OF NEUTRON COUNTERS USING MULTIPLE DETECTING LAYERS
    LOWDE, RD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1950, 21 (10): : 835 - 842
  • [4] Evaluation of the Response of a Neutron Detector of the Long-Counter Type Using Monte Carlo Transport Simulation
    Pazianotto, M. T.
    Goncalez, O. L.
    Federico, C. A.
    Carlson, B. V.
    XXXIII BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2011, 1351
  • [5] An improved long counter for neutron fluence measurement with a flat response over a wide energy range from 1 keV to 15 MeV
    Hu, Q. Y.
    Zhang, J. H.
    Zhang, D.
    Guo, H. S.
    Yang, G. Z.
    Li, B. J.
    Ye, F.
    Si, F. N.
    Liu, J.
    Fu, Y. C.
    Ning, J. M.
    Yang, J.
    Yang, H. H.
    Wang, W. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 768 : 43 - 45
  • [6] Long-term results of axillary Hair removal using linearly scanned Diode laser and scanned point-like Alexandrite Laser (Epicon-Study)
    Grunewald, S.
    Bodendorf, M. O.
    Zygouris, A.
    Simon, J-C
    Paasch, U.
    JOURNAL DER DEUTSCHEN DERMATOLOGISCHEN GESELLSCHAFT, 2011, 9 : 133 - 133
  • [7] A theoretical procedure for using multiple response time-temperature integrators for the design and evaluation of thermal processes
    Stoforos, NG
    Taoukis, PS
    FOOD CONTROL, 1998, 9 (05) : 279 - 287
  • [9] Statistical design-principal component analysis optimization of a multiple response procedure using cloud point extraction and simultaneous determination of metals by ICPOES
    Bezerra, Marcos A.
    Bruns, Roy E.
    Ferreira, Sergio L. C.
    ANALYTICA CHIMICA ACTA, 2006, 580 (02) : 251 - 257
  • [10] Design and performance of a compact lightweight hybrid thermal management system using phase change material and liquid cooling with a honeycomb-like structure for prismatic lithium-ion batteries
    Pu, Jin Huan
    Li, Yuan
    Li, Rui Chuang
    Hua, Nan
    Zhang, Huan
    Lu, Yucheng
    Panchal, Satyam
    Fraser, Roydon
    Fowler, Michael
    Zhang, Xuan-Kai
    JOURNAL OF POWER SOURCES, 2024, 624