Identification of micro-scale calorimetric devices

被引:0
|
作者
C Auguet
J Lerchner
V Torra
G Wolf
机构
[1] Polytechnical University of Catalonia c/,Cirg
[2] tu Bergakademie Freiberg,DFA
关键词
conduction calorimeters; systematic errors; chemical nose; liquid mixtures; nano-calorimeters; shape factor; identification; accuracy; TRIS reaction; working methodology;
D O I
暂无
中图分类号
学科分类号
摘要
An improved accuracy is researched in flat and silicon based nano-calorimeters related to fluid reaction via drop-to-drop 'reaction' or via a steady state in continuous injection of two reactants inside a working chamber. Two types of the experimental aspects of the sensitivity changes, related to 3-D effects, are described: drop effects and volume rate effects. To increase the accuracy, well-controlled joule measurements are dissipated in the manufacturer resistance and in several resistances in carefully controlled experiments. The shape factor (SF) values reduce the manufacturer's joule sensitivity up to fifty per cent. a working methodology is proposed: the results are compared with the standard TRIS reaction. The results suggest that the systematic error can be reduced to ±5%.
引用
收藏
页码:407 / 419
页数:12
相关论文
共 50 条
  • [1] Identification of micro-scale calorimetric devices
    Auguet, C.
    Seguin, J. L.
    Martorell, F.
    Moll, F.
    Torra, V.
    Lerchner, J.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2006, 86 (02) : 521 - 529
  • [2] Identification of micro-scale calorimetric devices II
    C. Auguet
    F. Martorell
    F. Moll
    V: Torra
    Journal of Thermal Analysis and Calorimetry, 2002, 70 (1) : 277 - 290
  • [3] Identification of micro-scale calorimetric devices - Part III. The 3-D effects
    Auguet, C
    Lerchner, J
    Torra, V
    Wolf, G
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2003, 71 (02) : 407 - 419
  • [4] Identification of micro-scale calorimetric devices - IV. Descriptive models in 3-D
    Auguet, C
    Lerchner, J
    Marinelli, P
    Martorell, F
    de Rivera, MR
    Torra, V
    Wolf, G
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2003, 71 (03) : 951 - 966
  • [5] Identification of Micro-scale Calorimetric Devices. I. Establishing the experimental rules for accurate measurements
    V. Torra
    C. Auguet
    J. Lerchner
    P. Marinelli
    H. Tachoire
    Journal of Thermal Analysis and Calorimetry, 2001, 66 : 255 - 264
  • [6] Identification of micro-scale calorimetric devices. I. Establishing the experimental rules for accurate measurements
    Torra, V
    Auguet, C
    Lerchner, J
    Marinelli, P
    Tachoire, H
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2001, 66 (01): : 255 - 264
  • [7] Identification of micro-scale calorimetric devicesIV. Descriptive models in 3-D
    C. Auguet
    J. Lerchner
    P. Marinelli
    F. Martorell
    M. Rodriguez de Rivera
    V. Torra
    G. Wolf
    Journal of Thermal Analysis and Calorimetry, 2003, 71 : 951 - 966
  • [8] Micro-scale and microfluidic devices for neurobiology
    Taylor, Anne M.
    Jeon, Noo Li
    CURRENT OPINION IN NEUROBIOLOGY, 2010, 20 (05) : 640 - 647
  • [9] Identification of micro-scale calorimetric devices II - Heat transfer models from two- or three-dimensional analysis
    Auguet, C
    Martorell, F
    Moll, F
    Torra, V
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2002, 70 (01): : 277 - 290
  • [10] Identification of micro-scale calorimetric devices - Part VI. An approach by RC-representative model to improvements in TAM microcalorimeters
    Kirchner, R
    de Rivera, MR
    Seidel, J
    Torra, V
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2005, 82 (01) : 179 - 184