Reliability of isokinetic ankle inversion- and eversion-strength measurement in neutral foot position, using the Biodex dynamometer

被引:0
|
作者
Ece Aydoğ
Sedat Tolga Aydoğ
Aytül Çakci
Mahmut Nedim Doral
机构
[1] Physical Medicine and Rehabilitation Clinics,SSK Educational Ankara Hospital
[2] Hacettepe University,Department of Sports Medicine
关键词
Ankle inversion; Ankle eversion; Isokinetic; Intratester reliability; Intertester reliability;
D O I
暂无
中图分类号
学科分类号
摘要
This study was designed to investigate the intratester and intertester reliability of isokinetic ankle inversion and eversion-strength measurement in neutral foot position in healthy adults using the Biodex dynamometer. Twenty-five men and women performed five maximal concentric contractions at 60 and 180°/s angular velocities. Two physicians tested each subject. The first physician applied the test four times, and the second physician three times. Reliability of peak torque was assessed by calculating the intraclass correlation coefficient (ICC). At both angular velocities, inversion strength was greater than eversion, and when the angular velocity was increased, inversion and eversion strength were decreased, as tested by both physicians. The first measurements of inversion and eversion strength of the first physician were significantly lower than the other measurements (p<0.01). The intratester ICCs for ankle inversion in healthy young adults were highly reliable (ICC 0.92–0.96), and for the eversion values ranged from 0.87 to 0.94. Intertester ICCs for ankle inversion and eversion peak torque values demonstrated a value of 0.95. Isokinetic tests of ankle inversion and eversion strength at 60 and 180°/s angular velocities in neutral foot position for healthy adults are highly reliable with the Biodex dynamometer.
引用
收藏
页码:478 / 481
页数:3
相关论文
共 7 条
  • [1] Reliability of isokinetic ankle inversion- and eversion-strength measurement in neutral foot position, using the Biodex dynamometer
    Aydog, E
    Aydog, ST
    Çakci, A
    Doral, MN
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2004, 12 (05) : 478 - 481
  • [2] Reliability of shoulder rotators isokinetic strength imbalance measured using the Biodex dynamometer
    Edouard, Pascal
    Codine, Philippe
    Samozino, Pierre
    Bernard, Pierre-Louis
    Herisson, Christian
    Gremeaux, Vincent
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2013, 16 (02) : 162 - 165
  • [3] Reliability of Ankle-Foot Complex Isokinetic Strength Assessment Using the Isomed 2000 Dynamometer
    Gonosova, Zuzana
    Linduska, Petr
    Bizovska, Lucia
    Svoboda, Zdenek
    [J]. MEDICINA-LITHUANIA, 2018, 54 (03):
  • [4] RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER
    Alfuth, Martin
    Murielle, Magali
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2016, 11 (01): : 72 - 84
  • [5] Test-Retest Reliability of Biodex System 4 Pro for Isometric Ankle-Eversion and -Inversion Measurement
    Tankevicius, Gediminas
    Lankaite, Donata
    Krisciunas, Aleksandras
    [J]. JOURNAL OF SPORT REHABILITATION, 2013, 22 (03) : 212 - 215
  • [6] Reliability of Isokinetic Strength Assessments of Knee and Hip Using the Biodex System 4 Dynamometer and Associations With Functional Strength in Healthy Children
    van Tittelboom, Vanessa
    Alemdaroglu-Guerbuez, Ipek
    Hanssen, Britta
    Heyrman, Lieve
    Feys, Hilde
    Desloovere, Kaat
    Calders, Patrick
    van den Broeck, Christine
    [J]. FRONTIERS IN SPORTS AND ACTIVE LIVING, 2022, 4
  • [7] Test-Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro
    Tuominen, Juho
    Leppanen, Mari
    Jarske, Heidi
    Pasanen, Kati
    Vasankari, Tommi
    Parkkari, Jari
    [J]. METHODS AND PROTOCOLS, 2023, 6 (02)