Comparison of Suomi-NPP OMPS total column ozone with Brewer and Dobson spectrophotometers measurements

被引:0
|
作者
Kaixu Bai
Chaoshun Liu
Runhe Shi
Wei Gao
机构
[1] East China Normal University,Key Laboratory of Geographic Information Science (Ministry of Education)
[2] East China Normal University,Joint Laboratory for Environmental Remote Sensing and Data Assimilation
[3] Colorado State University,Department of Ecosystem Science and Sustainability
来源
关键词
ozone mapping and profiler suite; total column ozone; Brewer; Dobson;
D O I
暂无
中图分类号
学科分类号
摘要
The objective of this study is to evaluate the accuracy of the daily nadir total column ozone products derived from the nadir mapper instrument on the Ozone Mapping and Profiler Suite (OMPS) flying onboard the Suomi National Polar-orbiting Partnership satellite (S-NPP) launched as a part of the Joint Polar Satellite System (JPSS) program between NOAA and NASA. Since NOAA is already operationally processing OMPS nadir total ozone products, evaluations were made in this study on the total column ozone research products generated by NASA’s science team, utilizing the latest version of their Backscatter Ultraviolet (BUV) retrieval algorithms, to provide insight into the performance of the operation system. Comparisons were made with globally distributed ground-based Brewer and Dobson spectrophotometer total column ozone measurements. Linear regressions show fair agreement between OMPS and ground-based total column ozone measurements with a root-mean-square error (RMSE) of approximately 3% (10 DU). The comparison results indicate that the OMPS total column ozone data are 0.59% higher than the Brewer measurements with a standard deviation of 2.82% while 1.09% higher than the Dobson measurements with a standard deviation of 3.27%. Additionally, the variability of relative differences between OMPS and ground total column ozone were analyzed as a function of latitude, time, viewing geometry, and total column ozone value. Results show a 2% bias over most latitudes and viewing conditions when total column ozone value varies between 220 DU and 450 DU.
引用
收藏
页码:369 / 380
页数:11
相关论文
共 50 条
  • [1] Comparison of Suomi-NPP OMPS total column ozone with Brewer and Dobson spectrophotometers measurements
    Bai, Kaixu
    Liu, Chaoshun
    Shi, Runhe
    Gao, Wei
    FRONTIERS OF EARTH SCIENCE, 2015, 9 (03) : 369 - 380
  • [2] Validation of ground-based visible measurements of total ozone by comparison with Dobson and Brewer spectrophotometers
    Van Roozendael, M
    Peeters, P
    Roscoe, HK
    De Backer, H
    Jones, AE
    Bartlett, L
    Vaughan, G
    Goutail, F
    Pommereau, JP
    Kyro, E
    Wahlstrom, C
    Braathen, G
    Simon, PC
    JOURNAL OF ATMOSPHERIC CHEMISTRY, 1998, 29 (01) : 55 - 83
  • [3] Validation of Ground-Based Visible Measurements of Total Ozone by Comparison with Dobson and Brewer Spectrophotometers
    M. Van Roozendael
    P. Peeters
    H. K. Roscoe
    H. De Backer
    A. E. Jones
    L. Bartlett
    G. Vaughan
    F. Goutail
    J.-P. Pommereau
    E. Kyro
    C. Wahlstrom
    G. Braathen
    P. C. Simon
    Journal of Atmospheric Chemistry, 1998, 29 : 55 - 83
  • [4] INTERCOMPARISON OF TOTAL OZONE MEASURED BY THE BREWER AND DOBSON SPECTROPHOTOMETERS AT TORONTO
    KERR, JB
    ASBRIDGE, IA
    EVANS, WFJ
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1988, 93 (D9): : 11129 - 11140
  • [5] Suomi-NPP OMPS Nadir Mapper's Operational SDR Performance
    Pan, Chunhui
    Zhou, Lihang
    Cao, Changyong
    Flynn, Lawrence
    Beach, Eric
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2019, 57 (02): : 1015 - 1024
  • [6] Evaluation of the performance of Suomi-NPP OMPS nadir mapper products using station measurements and OMI data
    Zhang, Yiwei
    Mao, Zhihua
    Tao, Bangyi
    Bai, Kaixu
    Chen, Peng
    Shi, Liangliang
    Huang, Haiqing
    Wang, Zheng
    JOURNAL OF APPLIED REMOTE SENSING, 2018, 12 (04):
  • [7] INTERNATIONAL COMPARISON OF DOBSON OZONE SPECTROPHOTOMETERS
    不详
    METEOROLOGICAL MAGAZINE, 1977, 106 (1265): : 385 - &
  • [8] MONITORING OF SUOMI-NPP OMPS CALIBRATION PARAMETERS AND UNDERSTANDING THEIR IMPACTS ON EARTH VIEW RADIANCE
    Liang, Ding
    Weng, Fuzhong
    Pan, Chunhui
    Sun, Ninghai
    2016 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2016, : 3025 - 3028
  • [9] A comparison of 40 years of SBUV measurements of column ozone with data from the Dobson/Brewer network
    Labow, Gordon J.
    McPeters, Richard D.
    Bhartia, Pawan K.
    Kramarova, Natalya
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2013, 118 (13) : 7370 - 7378
  • [10] Temperature and slant path effects in Dobson and Brewer total ozone measurements
    Scarnato, B.
    Staehelin, J.
    Peter, T.
    Groebner, J.
    Stuebi, R.
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2009, 114