Frequency measurement of a submillimeter wave gyrotron output

被引:0
|
作者
T. Idehara
Y. Yamagishi
T. Tatsukawa
机构
[1] Fukui University,Department of Applied Physics, Faculty of Engineering
关键词
Gyrotron; submillimeter wave; Michelson interferometer; Harmonic operation;
D O I
暂无
中图分类号
学科分类号
摘要
Measurement of frequency spectra of the output of a gyrotron in the millimeter to submillimeter wavelength range using a Michelson interferometer have been made. The results are compared with frequency measurements using a Fabry-Perot interferometer. A correction for mesh transmittance is used to give the true frequency spectrum. The method is used to search for the presence of higher cyclotron harmonics (n=f /fc=3,4,…) which may be generated along with the more intense fundamentals (n=1) or second harmonics (n=2), and to study mode competition between the fundamental and the second harmonic modes.
引用
下载
收藏
页码:259 / 272
页数:13
相关论文
共 50 条
  • [1] Frequency measurement of a submillimeter wave gyrotron output
    Idehara, T
    Yamagishi, Y
    Tatsukawa, T
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1997, 18 (01): : 259 - 272
  • [2] Frequency measurement of a submillimeter wave gyrotron output
    Fukui Univ, Fukui, Japan
    Int J Infrared Millim Waves, 1 (259-272):
  • [3] MEASUREMENT OF FREQUENCY-SPECTRUM OF SUBMILLIMETER-WAVE GYROTRON OUTPUT USING MICHELSON INTERFEROMETER
    IDEHARA, T
    TATSUKAWA, T
    OGAWA, I
    YAMAGISHI, Y
    KANEMAKI, T
    APPLIED PHYSICS LETTERS, 1993, 62 (08) : 832 - 833
  • [4] Simulation and measurement of frequency modulation in submillimeter-wave gyrotron
    Pereyaslavets, M
    Idehara, T
    Nishida, N
    Yoshida, K
    Ogawa, I
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1999, 27 (02) : 363 - 367
  • [5] Accurate frequency measurement of a submillimeter wave gyrotron output using a far-infrared laser as a reference
    Idehara, T
    Mitsudo, S
    Saito, S
    Ogawa, I
    Okajima, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (05): : 2860 - 2862
  • [6] CW Operation of a Submillimeter Wave Gyrotron (Gyrotron Fu IV) for High Stability of the Output Frequency
    T. Idehara
    K. Yoshida
    N. Nishida
    I. Ogawa
    M. L. Pereyaslavets
    T. Tatsukawa
    International Journal of Infrared and Millimeter Waves, 1998, 19 : 793 - 801
  • [7] cw operation of a submillimeter wave gyrotron (Gyrotron FU IV) for high stability of the output frequency
    Idehara, T
    Yoshida, K
    Nishida, N
    Ogawa, I
    Pereyaslavets, ML
    Tatsukawa, T
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1998, 19 (06): : 793 - 801
  • [8] Amplitude modulation of submillimeter wave gyrotron output
    Idehara, T
    Shimizu, Y
    Makino, S
    Ichikawa, K
    Tatsukawa, T
    Ogawa, I
    Brand, GF
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1997, 18 (02): : 391 - 403
  • [9] Amplitude modulation of submillimeter wave gyrotron output
    T. Idehara
    Y. Shimizu
    S. Makino
    K. Ichikawa
    T. Tatsukawa
    I. Ogawa
    G. F. Brand
    International Journal of Infrared and Millimeter Waves, 1997, 18 : 391 - 403
  • [10] Frequency modulation in a submillimeter-wave Gyrotron
    Idehara, T
    Pereyaslavets, M
    Nishida, N
    Yoshida, K
    Ogawa, I
    PHYSICAL REVIEW LETTERS, 1998, 81 (09) : 1973 - 1976