Reliability of near infrared spectroscopy (NIRS) for measuring forearm oxygenation during incremental handgrip exercise

被引:0
|
作者
Bert Celie
Jan Boone
Rudy Van Coster
Jan Bourgois
机构
[1] Faculty of Medicine and Health Science,Department of Health and Movement Sciences
[2] Ghent University,Department of Pediatrics
[3] Center for Sports Medicine,undefined
[4] Ghent University Hospital,undefined
[5] Division of Pediatric Neurology and Metabolism,undefined
[6] Ghent University Hospital,undefined
来源
关键词
Deoxy[Hb + Mb]; O; -extraction; SmO; Cyclic contraction; Forearm muscle;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to test the reliability of a new handgrip exercise protocol measuring forearm oxygenation in 20 healthy subjects on two occasions. The retest took place 48 h later and at the same time of the day. The incremental exercise consisted of 2 min steps of cyclic handgrip contraction (1/2 Hz) separated by 1 min of recovery. The exercise started at 20% MVC, was increased with 10% MVC each step and was performed until exhaustion (69.5 and 73% MVC). Near infrared spectroscopy (NIRS) was used to measure deoxygenation (deoxy[Hb + Mb]) and oxygen saturation (SmO2) in the forearm muscles. Prior to the exercise protocol an arterial occlusion of the forearm was performed until deoxy(Hb + Mb) did no longer increase. Maximal increase in deoxy[Hb + Mb] during 10 s of each exercise bout was expressed relative to the occlusion amplitude. ICC was used to examine the test–retest reliability. Significant ICC’s were reported at 50% (r = 0.466, p = 0.017) and 60% MVC (r = 0.553, p = 0.005). The group mean of the maximum increase in oxygen extraction was 45.6 ± 16.7% and at the retest 44.9 ± 17.0% with an ICC of r = 0.867 (p < 0.001) which could be classified (Landis and Koch 1979) as almost perfect. The absolute SmO2 values showed reliable ICC’s for every submaximal intensity except at 60% MVC. An ICC of r = 0.774 (p < 0.001) was found at maximal intensity. The results of the present study show that deoxy[Hb + Mb] and SmO2 responses during this protocol are highly reliable and indicate that this protocol could be used to get insight into deoxygenation and oxygen saturation in a population with low exercise tolerance.
引用
收藏
页码:2369 / 2374
页数:5
相关论文
共 50 条
  • [1] Reliability of near infrared spectroscopy (NIRS) for measuring forearm oxygenation during incremental handgrip exercise
    Celie, Bert
    Boone, Jan
    Van Coster, Rudy
    Bourgois, Jan
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (06) : 2369 - 2374
  • [2] Reliability Of A New Handgrip Exercise Protocol Measuring Forearm Oxygenation With Near Infrared Spectroscopy (nirs)
    Celie, Bert M.
    Boone, Jan
    Callewaert, Margot
    Bourgois, Jan
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 556 - 557
  • [3] Reliability Of A New Handgrip Exercise Protocol Measuring Forearm Oxygenation With Near Infrared Spectroscopy (nirs)
    Celie, Bert M.
    Boone, Jan
    Callewaert, Margot
    Bourgois, Jan
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 556 - 557
  • [4] Reliability of near-infrared spectroscopy in measuring muscle oxygenation during squat exercise
    Corral-Perez, Juan
    Marin-Galindo, Alberto
    Costilla, Manuel
    Casals, Cristina
    Munoz-Lopez, Alejandro
    Sanchez-Sixto, Alberto
    Sanudo, Borja
    Ponce-Gonzalez, Jesus Gustavo
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2024, 27 (11) : 805 - 813
  • [5] Reliability of near-infrared spectroscopy for measuring forearm and shoulder oxygenation in healthy males and females
    Albert G. Crenshaw
    Guilherme H. Elcadi
    Fredrik Hellstrom
    Svend Erik Mathiassen
    European Journal of Applied Physiology, 2012, 112 : 2703 - 2715
  • [6] Reliability of near-infrared spectroscopy for measuring forearm and shoulder oxygenation in healthy males and females
    Crenshaw, Albert G.
    Elcadi, Guilherme H.
    Hellstrom, Fredrik
    Mathiassen, Svend Erik
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (07) : 2703 - 2715
  • [7] Validation of a New NIRS Method for Measuring Muscle Oxygenation during Rhythmic Handgrip Exercise
    Soller, Babs R.
    Soyemi, Olusola
    Landry, Michelle
    Shear, Michael
    Wu, Jacqueline
    Hagan, R. Donald
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S248 - S249
  • [8] In vivo quantitative near-infrared spectroscopy in skeletal muscle during incremental isometric handgrip exercise
    van Beekvelt, MCP
    van Engelen, BGM
    Wevers, RA
    Colier, WNJM
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (03) : 210 - 217
  • [9] PARADOXICAL OXYGENATION OF MUSCLE DURING EXERCISE BY PATIENTS WITH DERMATOMYOSITIS AS DETECTED BY NEAR-INFRARED SPECTROSCOPY (NIRS)
    PARK, JH
    OLSEN, NJ
    LECH, G
    STEWARD, KR
    NEWMAN, J
    ADAMSGANDHI, LB
    KING, LE
    CHANCE, B
    ARTHRITIS AND RHEUMATISM, 1995, 38 (09): : 96 - 96
  • [10] Muscle Oxygenation during Cycle Exercise under Normoxic and Hypoxic Conditions - Near Infrared Spectroscopy (NIRS)
    Franke, Julia
    Geraskin, Dimitri
    Andre, Christiane
    Kohl-Bareis, Matthias
    Vega, Sandra Rojas
    Wahrmann, Berta Vera
    Bloch, Wilhelm
    Platen, Petra
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S63 - S63