Flow-Injection and Sequential-Injection Determinations of Paracetamol in Pharmaceutical Preparations Using Nitrosation Reaction

被引:0
|
作者
Rodjana Burakham
Supunnee Duangthong
Lop Patimapornlert
Narong Lenghor
Suphaphorn Kasiwad
Lalida Srivichai
Somchai Lapanantnoppakhun
Jaroon Jakmunee
Kate Grudpan
机构
[1] Chiang Mai University,Department of Chemistry, Faculty of Science
[2] Chiang Mai University,Institute for Science and Technology Research and Development
来源
Analytical Sciences | 2004年 / 20卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A simple FI and two different SI systems have been investigated for the determination of paracetamol by employing a simple reagent for a nitrosation reaction. It is based on the on-line nitrosation of paracetamol with sodium nitrite in an acidic medium. The formed nitroso derivative species reacts further with sodium hydroxide to convert it to a more stable compound. The yellow product is continuously monitored at 430 nm. The FI system is very simple and cost effective for fast manual operation (60 injections/h; y = 0.268x + 44.314, r2 = 0.9910 for 400 - 1000 mg/l and y = 0.1687x + 145.72, r2 = 0.9970 for 1000 - 2500 mg/l). The two SI systems with different components and configurations are automated and optimized for the conditions for which no extra dilution is to be required for sample handling: one with a syringe pump and two selection valves (60 samples/h; y = 0.1488x - 4.7297, r2 = 0.9946 for 400 - 1000 mg/l and y = 0.0858x + 63.933, r2 = 0.9849 for 1000 - 2500 mg/l); the other is simpler and more cost-effective, with an autoburette and only one selection valve (15 samples/h; y = 0.0072x + 1.1467, r2 = 0.9977 for 200 - 1000 mg/l and y = 0.0028x + 5.4699, r2 = 0.9879 for 1000 - 2500 mg/l). They have all been applied to assay paracetamol in pharmaceutical preparations. The obtained results agree with those by the US Pharmacopeia method.
引用
收藏
页码:837 / 840
页数:3
相关论文
共 50 条
  • [1] Flow-injection and sequential-injection determinations of paracetamol in pharmaceutical preparations using nitrosation reaction
    Burakham, R
    Duangthong, S
    Patimapornlert, L
    Lenghor, N
    Kasiwad, S
    Srivichai, L
    Lapanantnoppakhun, S
    Jakmunee, J
    Grudpan, K
    ANALYTICAL SCIENCES, 2004, 20 (05) : 837 - 840
  • [2] The automation of pharmaceutical analysis using sequential-injection techniques
    Liu, XZ
    Fang, ZL
    LABORATORY ROBOTICS AND AUTOMATION, 2000, 12 (02) : 60 - 66
  • [3] SEQUENTIAL OPTIMIZATION OF A FLOW-INJECTION SPECTROPHOTOMETRIC METHOD FOR THE ASSAY OF CHLORPROMAZINE IN PHARMACEUTICAL PREPARATIONS
    SULIMAN, FEO
    SULTAN, SM
    TALANTA, 1994, 41 (11) : 1865 - 1871
  • [4] Recent applications of flow-injection and sequential-injection analysis techniques to chemiluminescence determination of pharmaceuticals
    Mervartova, Katerina
    Polasek, Miroslav
    Calatayud, Jose Martinez
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 45 (03) : 367 - 381
  • [5] FLOW-INJECTION ANALYSIS - A NEW APPROACH TO PHARMACEUTICAL DETERMINATIONS
    RIOS, A
    DECASTRO, MDL
    VALCARCEL, M
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1985, 3 (02) : 105 - 121
  • [6] MICELLAR CATALYSIS IN FLOW-INJECTION SYSTEMS - THE NITROSATION REACTION
    JOHNSON, BF
    MALICK, RE
    GHEARING, B
    DORSEY, JG
    ANALYST, 1992, 117 (12) : 1833 - 1837
  • [7] SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS
    ALONSO, J
    BARTROLI, J
    LIMA, JLFC
    MACHADO, AASC
    ANALYTICA CHIMICA ACTA, 1986, 179 : 503 - 508
  • [8] Modulation of mobile phase composition in flow-injection/sequential-injection chromatography exploiting multisyringe flow analysis
    Mailen Fernández
    Manuel Miró
    Hilda M. González
    Víctor Cerdà
    Analytical and Bioanalytical Chemistry, 2008, 391 : 817 - 825
  • [9] Modulation of mobile phase composition in flow-injection/sequential-injection chromatography exploiting multisyringe flow analysis
    Fernandez, Mailen
    Miro, Manuel
    Gonzalez, Hilda M.
    Cerda, Victor
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (03) : 817 - 825
  • [10] BATCH AND FLOW-INJECTION DETERMINATION OF ETHYLENEDIAMINE IN PHARMACEUTICAL PREPARATIONS
    MILLA, M
    DECASTRO, RM
    GARCIAVARGAS, M
    MUNOZLEYVA, JA
    ANALYTICA CHIMICA ACTA, 1986, 179 : 289 - 297