SPR biosensor based on immobilized E.coli cells with autodisplayed Z-domains

被引:0
|
作者
Eun-Hang Lee
Gu Yoo
Joachim Jose
Min-Jung Kang
Seung-Min Song
Jae-Chul Pyun
机构
[1] Yonsei University,Department of Materials Sciences and Engineering
[2] University of Muenster,Institute of Pharmaceutical and Medical Chemistry
[3] Korea Institute of Science and Technology (KIST),undefined
来源
BioChip Journal | 2012年 / 6卷
关键词
Z-domain; Autodisplay; Parylene; Poly-Llysine; Surface plasmon resonance; Immunoassay;
D O I
暂无
中图分类号
学科分类号
摘要
The Z-domains of protein A was expressed as a fusion protein at the outer membrane of E.coli by using the autodisplay technology. Because of the specific affinity towards the Fc region of immunoglobulins (IgG’s), the Z-domains have been used for the orientation control of antibodies in order to improve the sensitivity of immunoassays. In this work, the E.coli with autodispalyed Z-domains was immobilized to the SPR biosensor by the charge interaction. The surface modification was carried out by covalent layering of the poly-L-lysine with amino groups to the parylene-H film with formyl groups. And then, the negatively charged E.coli cells were immobilized by charge interaction with the positivley charged of poly-L-lysine. The effectiveness of this layer for the immobilization of E.coli was estimated by counting the number of E.coli cells in comparison with the bare gold surface and the poly-L-lysine coated gold surface. For the test of feasibility of the immobilized E.coli cells to SPR biosensor, the stability of immobilized E.coli cells was estimated by treatment of salt solutions at the known concentrations to the immobilized E.coli cells which were bound through the charge interaction. From this test, the E.coli cells immobilized to the parylene-H film with poly-L-lysine coating were determined to be stable at the salt concentration of human serum. Then, the applicability of the immobilized E.coli cells with autodisplayed Z-domains was demonstrated by detection of C-reactive protein (CRP). The effect of orientation control with autodisplayed Z-domains was estimated by comparing the sensivities by immobilization through the physical adsorption and charge interaction to poly-L-lysine coated layer.
引用
收藏
页码:221 / 228
页数:7
相关论文
共 50 条
  • [1] SPR biosensor based on immobilized E.coli cells with autodisplayed Z-domains
    Lee, Eun-Hang
    Yoo, Gu
    Jose, Joachim
    Kang, Min-Jung
    Song, Seung-Min
    Pyun, Jae-Chul
    BIOCHIP JOURNAL, 2012, 6 (03) : 221 - 228
  • [2] Electrochemical ELISA based on E.coli with autodisplayed Z-domains
    Lee, Ju-Kyung
    Gu-Yoo
    Park, Min
    Jose, Joachim
    Pyun, Jae-Chul
    EUROSENSORS XXV, 2011, 25
  • [3] SPR biosensor by using E. coli outer membrane layer with autodisplayed Z-domains
    Park, Min
    Jose, Joachim
    Pyun, Jae-Chul
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 154 (02) : 82 - 88
  • [4] Electrochemical ELISA based on Escherichia coli with autodisplayed Z-domains
    Lee, Ju-Kyung
    Gu-Yoo
    Park, Min
    Jose, Joachim
    Kang, Min-Jung
    Pyun, Jae-Chul
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 175 : 46 - 52
  • [5] Magnetic-bead-based immunoassay using E. coli cells with autodisplayed Z-domains
    Yoo, Gu
    Bong, Ji-Hong
    Park, Min
    Kang, Min-Jung
    Jose, Joachim
    Pyun, Jae-Chul
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 53 (02) : 118 - 122
  • [6] E.coli outer membrane with autodisplayed Z-domain as a molecular recognition layer of SPR biosensor
    Park, M.
    Jose, J.
    Pyun, J. C.
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 1475 - +
  • [7] Flow cytometric immunoassay using E. coli with autodisplayed Z-domains
    Park, Min
    Bong, Ji-Hong
    Yoo, Gu
    Jose, Joachim
    Kang, Min-Jung
    Pyun, Jae-Chul
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 53 (03) : 181 - 188
  • [8] Ultrasonic isolation of the outer membrane of Escherichia coli with autodisplayed Z-domains
    Bong, Ji-Hong
    Yoo, Gu
    Park, Min
    Kang, Min-Jung
    Jose, Joachim
    Pyun, Jae-Chul
    ENZYME AND MICROBIAL TECHNOLOGY, 2014, 66 : 42 - 47
  • [9] FACS-based immunoassay of troponin-I using E-coli cells with autodisplayed Z-domains
    Park, Min
    Bong, Ji-Hong
    Chang, Young Wook
    Yoo, Gu
    Jose, Joachim
    Kang, Min-Jung
    Pyun, Jae-Chul
    ANALYTICAL METHODS, 2014, 6 (06) : 1700 - 1708
  • [10] Isolation and characterization of the outer membrane of Escherichia coli with autodisplayed Z-domains
    Park, Min
    Yoo, Gu
    Bong, Ji-Hong
    Jose, Joachim
    Kang, Min-Jung
    Pyun, Jae-Chul
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2015, 1848 (03): : 842 - 847