Effects of congruent and incongruent visual cues on speech perception and brain activity in cochlear implant users

被引:0
|
作者
Jae-Jin Song
Hyo-Jeong Lee
Hyejin Kang
Dong Soo Lee
Sun O. Chang
Seung Ha Oh
机构
[1] Seoul National University Bundang Hospital,Department of Otorhinolaryngology
[2] Hallym University College of Medicine,Head and Neck Surgery
[3] Sensory Organ Research Institute,Department of Otorhinolaryngology
[4] Seoul National University Medical Research Center,Head and Neck Surgery
[5] Seoul National University Hospital,Department of Nuclear Medicine
[6] Seoul National University Hospital,Department of Otorhinolaryngology
来源
关键词
Cochlear implant; Deafness; Positron emission tomography; Audiovisual; Plasticity;
D O I
暂无
中图分类号
学科分类号
摘要
While deafness-induced plasticity has been investigated in the visual and auditory domains, not much is known about language processing in audiovisual multimodal environments for patients with restored hearing via cochlear implant (CI) devices. Here, we examined the effect of agreeing or conflicting visual inputs on auditory processing in deaf patients equipped with degraded artificial hearing. Ten post-lingually deafened CI users with good performance, along with matched control subjects, underwent H215O-positron emission tomography scans while carrying out a behavioral task requiring the extraction of speech information from unimodal auditory stimuli, bimodal audiovisual congruent stimuli, and incongruent stimuli. Regardless of congruency, the control subjects demonstrated activation of the auditory and visual sensory cortices, as well as the superior temporal sulcus, the classical multisensory integration area, indicating a bottom-up multisensory processing strategy. Compared to CI users, the control subjects exhibited activation of the right ventral premotor-supramarginal pathway. In contrast, CI users activated primarily the visual cortices more in the congruent audiovisual condition than in the null condition. In addition, compared to controls, CI users displayed an activation focus in the right amygdala for congruent audiovisual stimuli. The most notable difference between the two groups was an activation focus in the left inferior frontal gyrus in CI users confronted with incongruent audiovisual stimuli, suggesting top-down cognitive modulation for audiovisual conflict. Correlation analysis revealed that good speech performance was positively correlated with right amygdala activity for the congruent condition, but negatively correlated with bilateral visual cortices regardless of congruency. Taken together these results suggest that for multimodal inputs, cochlear implant users are more vision-reliant when processing congruent stimuli and are disturbed more by visual distractors when confronted with incongruent audiovisual stimuli. To cope with this multimodal conflict, CI users activate the left inferior frontal gyrus to adopt a top-down cognitive modulation pathway, whereas normal hearing individuals primarily adopt a bottom-up strategy.
引用
收藏
页码:1109 / 1125
页数:16
相关论文
共 50 条
  • [1] Effects of congruent and incongruent visual cues on speech perception and brain activity in cochlear implant users
    Song, Jae-Jin
    Lee, Hyo-Jeong
    Kang, Hyejin
    Lee, Dong Soo
    Chang, Sun O.
    Oh, Seung Ha
    [J]. BRAIN STRUCTURE & FUNCTION, 2015, 220 (02): : 1109 - 1125
  • [2] Cortical activity and speech perception performance in cochlear implant users
    Fujiki, N
    Naito, Y
    Hirano, S
    Kojima, H
    Shiomi, Y
    Nishizawa, S
    Konishi, J
    Honjo, I
    [J]. UPDATES IN COCHLEAR IMPLANTATION, 2000, 57 : 32 - 35
  • [3] Gaze Fixations During the Perception of Congruent and Incongruent Visual and Auditory Affective Cues
    McManus, S. M.
    Robins, D. L.
    Tone, E. B.
    Washburn, D. A.
    [J]. CLINICAL NEUROPSYCHOLOGIST, 2010, 24 (04) : 590 - 591
  • [4] Spectral and temporal cues in cochlear implant speech perception
    Nie, K
    Barco, A
    Zeng, FG
    [J]. EAR AND HEARING, 2006, 27 (02): : 208 - 217
  • [5] Ceiling effects for speech perception tests in pediatric cochlear implant users
    Spitzer, Emily R.
    Landsberger, David M.
    Lichtl, Alexandra J.
    Waltzman, Susan B.
    [J]. COCHLEAR IMPLANTS INTERNATIONAL, 2024, 25 (01) : 69 - 80
  • [6] Normal-Hearing Listeners' and Cochlear Implant Users' Perception of Pitch Cues in Emotional Speech
    Gilbers, Steven
    Fuller, Christina
    Gilbers, Dicky
    Broersma, Mirjam
    Goudbeek, Martijn
    Free, Rolien
    Baskent, Deniz
    [J]. I-PERCEPTION, 2015, 6 (05): : 1 - 19
  • [7] Perception of Sung Speech in Bimodal Cochlear Implant Users
    Crew, Joseph D.
    Galvin, John J., III
    Fu, Qian-Jie
    [J]. TRENDS IN HEARING, 2016, 20
  • [8] Visual Temporal Acuity Is Related to Auditory Speech Perception Abilities in Cochlear Implant Users
    Jahn, Kelly N.
    Stevenson, Ryan A.
    Wallace, Mark T.
    [J]. EAR AND HEARING, 2017, 38 (02): : 236 - 243
  • [9] Cochlear Blood Flow and Speech Perception Ability in Cochlear Implant Users
    Nakashima, Tsutomu
    Hattori, Taku
    Sone, Michihiko
    Asahi, Kiyomitsu
    Matsuda, Naoko
    Teranishi, Masaaki
    Yoshida, Tadao
    Kato, Ken
    Sato, Eisuke
    [J]. OTOLOGY & NEUROTOLOGY, 2012, 33 (02) : 165 - 168
  • [10] Intonational cues for speech perception in noise by cochlear implant listeners
    Hilal Dincer D’Alessandro
    Patrizia Mancini
    [J]. European Archives of Oto-Rhino-Laryngology, 2020, 277 : 3315 - 3321