Ion-molecule adduct formation in tandem mass spectrometry

被引:0
|
作者
Élida Alechaga
Encarnación Moyano
Maria Teresa Galceran
机构
[1] University of Barcelona,Department of Analytical Chemistry
来源
关键词
Tandem mass spectrometry; Ion-molecule adducts; Orbitrap; Triple quadrupole; Ion trap;
D O I
暂无
中图分类号
学科分类号
摘要
Nowadays most LC-MS methods rely on tandem mass spectrometry not only for quantitation and confirmation of compounds by multiple reaction monitoring (MRM), but also for the identification of unknowns from their product ion spectra. However, gas-phase reactions between charged and neutral species inside the mass analyzer can occur, yielding product ions at m/z values higher than that of the precursor ion, or at m/z values difficult to explain by logical losses, which complicate mass spectral interpretation. In this work, the formation of adduct ions in the mass analyzer was studied using several mass spectrometers with different mass analyzers (ion trap, triple quadrupole, and quadrupole-Orbitrap). Heterocyclic amines (AαC, MeAαC, Trp-P-1, and Trp-P-2), photo-initiators (BP and THBP), and pharmaceuticals (phenacetin and levamisole) were selected as model compounds and infused in LCQ Classic, TSQ Quantum Ultra AM, and Q-Exactive Orbitrap (ThermoFisher Scientific) mass spectrometers using electrospray as ionization method. The generation of ion-molecule adducts depended on the compound and also on the instrument employed. Adducts with neutral organic solvents (methanol and acetonitrile) were only observed in the ion trap instrument (LCQ Classic), because of the ionization source on-axis configuration and the lack of gas-phase barriers, which allowed inertial entrance of the neutrals into the analyzer. Adduct formation (only with water) in the triple quadrupole instruments was less abundant than in the ion trap and quadrupole-Orbitrap mass spectrometers, because of the lower residence time of the reactive product ions in the mass analyzer. The moisture level of the CID and/or damper gas had a great effect in beam-like mass analyzers such as triple quadrupole, but not in trap-like mass analyzers, probably because of the long residence time that allowed adduct formation even with very low concentrations of water inside the mass spectrometer.
引用
收藏
页码:1269 / 1277
页数:8
相关论文
共 50 条
  • [1] Ion-molecule adduct formation in tandem mass spectrometry
    Alechaga, Elida
    Moyano, Encarnacion
    Teresa Galceran, Maria
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (04) : 1269 - 1277
  • [2] TANDEM MASS SPECTROMETER FOR STUDY OF ION-MOLECULE REACTIONS
    FUTRELL, JH
    MILLER, CD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (11): : 1521 - &
  • [3] Ion-molecule reactions in plasma source mass spectrometry
    Koyanagi, GK
    Bohme, DK
    PLASMA SOURCE MASS SPECTROMETRY: THE NEW MILLENNIUM, 2001, (267): : 117 - 129
  • [4] MASS-SPECTROMETRY AND ION-MOLECULE REACTIONS IN SILANES
    LAMPE, FW
    SILICON CHEMISTRY, 1988, : 513 - 523
  • [5] TANDEM MASS-SPECTROMETER FOR STUDY OF ION-MOLECULE REACTIONS
    MERCEA, V
    IOANOVICIU, D
    CUNA, C
    ARDELEAN, P
    URSU, D
    REVUE ROUMAINE DE PHYSIQUE, 1974, 19 (08): : 883 - 889
  • [6] TANDEM MASS-SPECTROMETER FOR ION-MOLECULE COLLISION STUDIES
    ARDELEAN, P
    CUNA, C
    IOANOVICIU, D
    DUNCA, F
    MALZ, L
    PETRUT, M
    ORGANIC MASS SPECTROMETRY, 1993, 28 (05): : 510 - 512
  • [7] ESTIMATION OF MUTAGENIC CARCINOGENIC POTENTIAL OF ENVIRONMENTAL CONTAMINANTS BY ION-MOLECULE REACTIONS AND TANDEM MASS-SPECTROMETRY
    FREEMAN, JA
    JOHNSON, JV
    HAIL, ME
    YOST, RA
    KUEHL, DW
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (01) : 110 - 115
  • [8] Drug detection by tandem mass spectrometry on the basis of adduct formation
    Dziadosz, Marek
    Klintschar, Michael
    Teske, Joerg
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 955 : 108 - 109
  • [9] FORMATION OF IONS IN MASS SPECTROMETERS BY ION-MOLECULE REACTIONS
    BEYNON, JH
    WILLIAMS, AE
    SAUNDERS, RA
    LESTER, GR
    TRANSACTIONS OF THE FARADAY SOCIETY, 1961, 57 (08): : 1259 - &
  • [10] Study on the formation of an amoxicillin adduct with methanol using electrospray ion trap tandem mass spectrometry
    Grujic, Svetlana
    Vasiljevic, Tatjana
    Lausevic, Mila
    Ast, Teodor
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (01) : 67 - 74