Seismic behavior and damage assessment of mid-rise cold-formed steel-framed buildings with normal and reinforced beam-column joints

被引:7
|
作者
Jiang, Liqiang [1 ,2 ,3 ]
Zhang, Xingshuo [1 ,3 ]
Ye, Jihong [4 ]
Jiang, Lizhong [1 ,3 ]
Zhou, Lingyu [1 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha 410075, Peoples R China
[2] Sichuan Univ, Key Lab Sichuan Prov, Failure Mech & Engn Disaster Prevent & Mitigat, Chengdu 610065, Peoples R China
[3] Cent South Univ, Natl Engn Lab High Speed Railway Construct, Changsha 410075, Peoples R China
[4] China Univ Min & Technol, Jiangsu Key Lab Environm Impact & Struct Safety E, Xuzhou 211116, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Cold-formed steel-framed structure; Mid-rise building; Beam-column joint; Seismic behavior; Seismic damage; SHEAR WALLS; CYCLIC PERFORMANCE; CONNECTIONS; MECHANISM; DESIGN; TESTS;
D O I
10.1007/s43452-021-00278-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigated the effects of normal and reinforced beam-column joints on seismic behavior and damages of mid-rise cold-formed steel (CFS) framed buildings, where the reinforced beam-column joint is strengthened by a pair of steel blocks and a gusset plate. Shaking table tests were conducted on a 5-story CFS frame building with normal beam-column joint (CFSM-NJ) and a 5-story CFS frame building with same configurations but with reinforced beam-column joint (CFSM-RJ). Formulae fitted from four damage models were used to assess the seismic damage indexes of these test buildings, and the assessed results were validated by the damage indexes observed from tests. The results show the following: (1) the CFSM-NJ failed due to plastic hinges formed at the column bases and large separate deformation at the beam-column joints; however, the weaken-story failure mode was appeared on the CFSM-RJ; (2) the peak inter-story displacement of the building was reduced about 10-30% due to the reinforced beam-column joints; (3) the Park-Ang model is more appropriate for seismic damage assessment of column bases, but all the damage models overestimates the seismic damages of CFS beams. Finally, the authors comment on the difference between the assessed seismic damage indexes and the observed results, and the maximum damage indexes obtained from the simplified formulae are recommended as the preliminary assessed damages for mid-rise CFS buildings.
引用
收藏
页数:16
相关论文
共 29 条
  • [1] Practice-oriented numerical model for seismic response of cold-formed steel-framed mid-rise buildings
    Singh, Amanpreet
    Zhang, Zhidong
    Wang, Xiang
    Schafer, Benjamin W.
    Hutchinson, Tara C.
    ENGINEERING STRUCTURES, 2024, 319
  • [2] Seismic analysis on mid-rise cold-formed steel structure with reinforced end studs
    Wang X.
    Ye J.
    Ye, Jihong (jhye@cumt.edu.cn), 2017, Harbin Institute of Technology (49): : 16 - 23
  • [3] Behavior and performance of cold-formed steel-framed houses under seismic action
    Dubina, Dan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (7-8) : 896 - 913
  • [4] Amplification of Seismic Loads on Cold-Formed Steel Mid-Rise Podium Structures
    Lahey, Daniel
    Xu, Lei
    PROCEEDINGS OF THE CANADIAN SOCIETY OF CIVIL ENGINEERING ANNUAL CONFERENCE 2022, VOL 2, CSCE 2022, 2023, 348 : 819 - 832
  • [5] Impact of Wall Configurations on Seismic Fragility of Steel-Sheathed Cold-Formed Steel-Framed Buildings
    Jiang, Liqiang
    Ye, Jihong
    ADVANCES IN CIVIL ENGINEERING, 2018, 2018
  • [6] Seismic risk assessment of mid-rise cold-formed steel structures in China considering various uncertainties
    Ye, Jihong
    Jiang, Liqiang
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2021, 54 (02): : 74 - 83
  • [7] Evaluation of Seismic Deflection Amplification Factor for Buildings Utilizing Cold-Formed Steel-Framed Shear Walls
    Eladly, Mohammed M.
    Schafer, Benjamin W.
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (07)
  • [8] COLD-FORMED STEEL SHEET WALL FOR MID-RISE CONSTRUCTION: SEISMIC PERFORMANCE AND DESIGN METHOD
    Yu, Cheng
    Jia, Pengchun
    Zhang, Wenying
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1182 - 1193
  • [9] Experimental investigation on the structural performance of a reinforced cold-formed steel beam-column joint
    Wang Xingxing
    Ye Jihong
    Wang Wei
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2018, 45 (12) : 1027 - 1039
  • [10] Beam-Column Connections Behavior of Cold-Formed Steel Members: New Experimental Configuration
    Ahmed Shamel Fahmy
    Sherine Mostafa Swelem
    Hadi Hasan Mussttaf
    KSCE Journal of Civil Engineering, 2020, 24 : 2147 - 2159