Extraction of the target isotope on the collector by the ion cyclotron resonance method

被引:0
|
作者
E. P. Potanin
机构
[1] Russian Research Centre Kurchatov Institute,
来源
Technical Physics | 2008年 / 53卷
关键词
28.60.+s; 52.50.Qt;
D O I
暂无
中图分类号
学科分类号
摘要
Theoretical issues concerning isotope separation by the ion cyclotron resonance method are considered. A version of the experimental ion cyclotron resonance setup and ways of producing a plasma stream are described. Techniques used to vaporize the working agent and its transport to the ioniation zone are discussed. The separating characteristics of the hot-particle collector at certain parameters of the setup and plasma are calculated. A gadolinium isotope mixture is used as a model. The dependence of the 157Gd target isotope concentration on the separating plate on the longitudinal coordinate reckoned from the front edge of the separator is analyzed for different frequency offsets. The target isotope extraction ratio versus the plate distance of the separator for different values of the offset from the resonance frequency is found.
引用
收藏
页码:445 / 450
页数:5
相关论文
共 50 条
  • [1] Extraction of the target isotope on the collector by the ion cyclotron resonance method
    Potanin, E. P.
    TECHNICAL PHYSICS, 2008, 53 (04) : 445 - 450
  • [2] Isotope separation in plasmas by the ion-cyclotron resonance method
    Dubinov, AE
    Kornilova, IY
    Selemir, VD
    PHYSICS OF PARTICLES AND NUCLEI, 2001, 32 (04) : 443 - 452
  • [3] Electrical characteristics of collector system at lithium isotope separation by ion cyclotron resonance heating.
    Dolgolenko, DA
    Karchevsky, AI
    Laz'ko, VS
    Muromkin, YA
    Pashkovsky, VG
    INTERNATIONAL CONFERENCE ON PHENOMENA IN IONIZED GASES, VOL II, PROCEEDINGS, 1999, : 63 - 64
  • [4] PARAMETRIC INSTABILITY INFLUENCE ON ISOTOPE SEPARATION BY ION-CYCLOTRON RESONANCE METHOD
    Olshansky, V. V.
    Stepanov, K. N.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2006, (06): : 204 - 206
  • [5] Coefficient of the extraction of the target isotope and optimum parameters of a collector of heated ions in the context of the ICR method of isotope separation
    Karchevskii, AI
    Potanin, EP
    PLASMA PHYSICS REPORTS, 2002, 28 (07) : 565 - 571
  • [6] Coefficient of the Extraction of the Target Isotope and Optimum Parameters of a Collector of Heated Ions in the Context of the ICR Method of Isotope Separation
    A. I. Karchevskiĭ
    E. P. Potanin
    Plasma Physics Reports, 2002, 28 : 565 - 571
  • [7] Plasma isotope separation based on ion cyclotron resonance
    Dolgolenko, D. A.
    Muromkin, Yu A.
    PHYSICS-USPEKHI, 2009, 52 (04) : 345 - 357
  • [8] Characteristics of a hot ion collector placed in a weak ion cyclotron resonance magnetic field
    A. I. Karchevskii
    E. P. Potanin
    Technical Physics, 2003, 48 : 90 - 95
  • [9] Characteristics of a hot ion collector placed in a weak ion cyclotron resonance magnetic field
    Karchevskii, AI
    Potanin, EP
    TECHNICAL PHYSICS, 2003, 48 (01) : 90 - 95
  • [10] Extraction studies on electron cyclotron resonance ion sources
    Leroy, R
    Mandin, J
    Bertrand, P
    Lecesne, N
    Pacquet, JY
    Robert, E
    Sortais, P
    Villari, ACC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 1350 - 1352